During  the installation of the indoor and outd-
oor units the access to the working area should 
be forbidden to children.
Unforeseeable accidents could happen.

Make sure that  the base of  the outdoor unit  is
firmly fixed.

Check that air  cannot enter the refrigerant sys- 
tem and check for  refrigerant leaks when  mo-
ving the air conditioner. 

SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER 

Carry out a test cycle after installing the air co-
nditioner and record the operating data. 

The ratings of the fuse installed in the built  in- 
control unit are  T 5A /  250V    . 

The user must  protect  the  indoor unit  with a 
fuse of  suitable capacity for the maximum  in-
put current or with another overload protection
device. 

Check that the socket  is suitable for the plug , 
otherwise have the socket changed. 

Do not install the appliance at  a  distance  of 
less than 50 cm from inflammable substances 
(alcohol, etc.) Or from pressurised containers 
(e.g. spray cans). 

If  the appliance  is used  in areas without the 
possibility of ventilation, precautions must be 
taken to prevent any leaks  of refrigerant  gas
from remaining in the environment and creat-
ing a danger of fire 

Read this guide before installing and using  the
appliance.

The appliance must be fitted with means for 
disconnection from the supply mains having 
a contact separation in all poles that provide 
full disconnection under overvoltage 
category III conditions, and these means 
must be incorporated in the fixed wiring in 
accordance with the wiring rules. 

This appliance is not intended for use by 
persons (including children) with reduced 
physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they 
have been given supervision or instruction 
concerning use of the appliance by a person 
responsible for their safety.

Children should be supervised to ensure that 
they do not play with the appliance.

The air conditioner must be installed by 
professional or qualified persons.

The appliance must be installed in accordance 
with national wiring regulations.

Содержание TCLSS09

Страница 1: ...Model TCLSS09 2 5kW Cooling 2 6kW Heating TCLSS12 3 2kW Cooling 3 2kW Heating TCLSS18 5 0kW Cooling 5 2kW Heating TCLSS24 7 0kW Cooling 7 5kW Heating TCLSS28 7 8kW Cooling 8 0kW Heating...

Страница 2: ......

Страница 3: ...Y PRECAUTIONS NAMES OF PARTS INDOOR UNIT DISPLAY OPERATING INSTRUCTIONS PROTECTION INSTALLATION MANUAL MAINTENANCE TROUBLESHOOTING EMERGENCY FUNCTION AUTO RESTART FUNCTION REMOTE CONTROLLER 1 4 5 6 7...

Страница 4: ...ised containers e g spray cans If the appliance is used in areas without the possibility of ventilation precautions must be taken to prevent any leaks of refrigerant gas from remaining in the environm...

Страница 5: ...used for any other purpose such as for drying clothes cooling food etc The packaging materials are recyclable and should be disposed of in the separate waste bins Take the air conditioner at the end o...

Страница 6: ...e the air could contain gas oil or sulphur or near sources of heat Do not climb onto or place any heavy or hot objects on top of the appliance Do not leave windows or doors open for long when the air...

Страница 7: ...am of the appliance and may not correspond to the appearance of the units that have been purchased No Description 13 Air outlet grille Terminal block cover 14 gas valve 15 liquid valve 16 11 Indoor un...

Страница 8: ...d Function POWER This symbol appears when the unit is power on 1 2 3 4 5 Temperature display if present Error code 1 Lights up during Timer operation when the air conditioner is operational 2 Displays...

Страница 9: ...t you just need to press the button again a single long beep 4 After 30 minutes in forced operation the air conditioner will automatically start working in 23 cooling mode auto fan speed The FEEL func...

Страница 10: ...witch on off HEALTHY funtion It is a button which controls the ionizer or plasma generator only for inverter models In cooling mode press this button the temperature will increase 2 on the base of set...

Страница 11: ...indicator SIGNAL RECEPTION indicator TIMER OFF indicator TIMER ON indicator AUTO FAN indicator LOW FAN SPEED indicator or MIDDLE FAN SPEED indicator or or HIGH FAN SPEED indicator QUIET or or SLEEP in...

Страница 12: ...e controller toward the Air conditioner 2 Check that there are no objects between the remote control and the Signal receptor in the indoor unit 3 Never leave the remote controller exposed to the rays...

Страница 13: ...ibuted in the room It is possible to position the direction of the air in the optimal In cooling mode orient the flaps in horizontal direction In heating mode orient the flaps downward as the warm air...

Страница 14: ...ioner adjust the temperature 1 the speed 2 and the direction of the air flow 3 by pressing the button indicated HEAT The heating function allows the air conditi oner to heat the room To activate the h...

Страница 15: ...ature with pressing the button or Press TIMER at the second time set the rest time with pressing the button or Press TIMER at the third time confirm the setting then the rest time to next automatical...

Страница 16: ...NG or HEATING This function reduces the humid ity of the air to make the room more comfortable To set the DRY mode Press MODE untill DRY appears in the display An automatic function of alternating coo...

Страница 17: ...dually decreased by 2 during the first 2 hours of operation After 10 hours running in sleep mode the air conditio ner is swicthed off automatically I FEEL MODE FAN SWING SLEEP POWER SLEEP TIMER RUN In...

Страница 18: ...ow 21 Room temperature is below 18 C For T1 Climate condition models For Tropical T3 Climate condition models The unit does not operate immediately if it is turned on after being turned off or after c...

Страница 19: ...r drain pipe 300 500 2000 300 minimum space to be reserved mm showing in the picture 50 0 Installation Diagram INDOOR UNIT OUTDOOR UNIT The purchaser must ensure that the person and or company who is...

Страница 20: ...tapping screws 5 Be sure that the rear panel has been fixed firmly enough to withstand the weight 1 Make the piping hole 55 in the wall at a slight downward slant to the outdoor side 2 Insert the pipi...

Страница 21: ...Place the drain hose below the piping taking care not to create siphons 2 The drain hose must slant downwards to aid drainage 3 Do not bend the drain hose or leave it protruding or twisted and do not...

Страница 22: ...or unit The indoor unit should be installed on a solid wall and fastened securely The following procedure must be observed before co nnecting the pipes and connecting cables decide which is the best p...

Страница 23: ...is not sufficient there will probably be some leakage With excessive tightening torque there will also be some leakage as the flange could be damaged 3 The surest system consists in tightening the co...

Страница 24: ...vacuum pump hose 8 Replace and tighten all the caps on the valves 3 way valve diagram connect to indoor unit open position spindle service port cap Connect to outdoor unit Valve core needle INSTALLAT...

Страница 25: ...erant 1 1 4 6 3 8 9 52 1 4 6 1 4 6 1 4 6 1 4 6 3 8 9 52 3 8 9 52 1 2 12 1 2 12 3 8 9 52 3 8 9 52 5 8 15 88 5 8 15 88 3m 3m 3m 3m 4m 4m 4m R22 MODEL capacity Btu h 7k 9k 12k 15 18k 22 24k 28 30k 36k Li...

Страница 26: ...inal block For different models the wiring diagram may be different Please refer to the wiring diagrams pasted on the indoor unit and outdoor unit respectively On indoor unit the wiring diagram is pas...

Страница 27: ...5mm 2 1 0mm 2 1 5mm 2 1 5mm 2 1 5mm 2 1 5mm 2 1 0mm 2 1 5mm 2 1 0mm 2 1 5mm 2 1 0mm 2 0 75mm 2 1 5mm 2 1 0mm 2 1 5mm 2 1 0mm 2 1 5mm 2 1 5mm 2 1 0mm INVERTER TYPE MODEL capacity Btu h AWG16 AWG18 AWG1...

Страница 28: ...nd lift it till its greatest stroke and then unhooking it from the hinges to make the cleaning easier 2 Clean the indoor unit using a cloth with the water not higher than 40 and neutral soap Never use...

Страница 29: ...his occurs when the air in the room becomes very cold for example in the COOLING or DEHUMIDIFYING DRY modes This noise is made by the expansion or contraction of the front panel due to variations in t...

Страница 30: ......

Страница 31: ......

Страница 32: ...CONTACT DETAILS Glen Dimplex Australia Pty Ltd 1340 Ferntree Gully Road Scoresby VIC 3179 Australia Ph 1300 556 816 http www tclair com au Http www tclair com au...

Отзывы: