TCL TCLSS09 Скачать руководство пользователя страница 28

25

MAINTENANCE

Periodic  maintenance  is  essential  for  keeping your air 
conditioner efficient.
Before  carrying  out  any  maintenance ,  disconnect the 
power supply by taking the plug out from the socket.

INDOOR UNIT

ANTIDUST FILTERS

1. Open  the  front panel following  the direction  of  the 
    arrow
2. Keeping the front panel raised with one hand, take out 
    the air filter with the other hand
3. Clean the filter with water ;  if the filter is soiled with 
    oil,it can be washed with warm water  (not exceeding 
    45

).

    Leave to dry in a cool and dry place. 
4. Keeping the front panel raised with one hand ,  insert 
    the air filter with the other hand
5. Close   

The  electrostatic  and  the  deodorant filter (if installed)
cannot  be  washed  or regenerated and must be replaced 
with new filters after every 6 months.

CLEANING THE HEAT EXCHANGER

1. Open  the  front  panel  of  the  unit  and  lift  it till its 
    greatest stroke and then unhooking it from the hinges 
    to make the cleaning easier.
2. Clean  the  indoor  unit  using  a  cloth  with the water 
    ( not higher than  40

)  and  neutral soap . Never use 

    aggressive solvents or detergents. 
3. If  the outdoor unit  is clogged ,  remove the leaves and 
    the waste and remove the dust with air jet or a bit of water.

END OF SEASON MAINTENANCE

1. Disconnect the automatic switch or the plug.
2. Clean and replace the filters
3. On a sunny day let the conditioner work in ventilation for some hours , so that the inside of the unit can 
    dry completely..

 REPLACING THE BATTERIES

When:  
             
How:    
             

N.B:  Use only new batteries. Remove the batteries from the remote controller when the conditioner is not in 
          operation

WARNING ! Do  not  throw  batteries  into  common  rubbish ,  they  should  be disposed of  in the special 
                      containers situated in the collection points.

antidust filter

 There is no confirmation beep heard from the indoor unit. 
 The LCD doesn

 act.

 Take off  the cover at back. 
 Place the new batteries respecting the s and - .

Содержание TCLSS09

Страница 1: ...Model TCLSS09 2 5kW Cooling 2 6kW Heating TCLSS12 3 2kW Cooling 3 2kW Heating TCLSS18 5 0kW Cooling 5 2kW Heating TCLSS24 7 0kW Cooling 7 5kW Heating TCLSS28 7 8kW Cooling 8 0kW Heating...

Страница 2: ......

Страница 3: ...Y PRECAUTIONS NAMES OF PARTS INDOOR UNIT DISPLAY OPERATING INSTRUCTIONS PROTECTION INSTALLATION MANUAL MAINTENANCE TROUBLESHOOTING EMERGENCY FUNCTION AUTO RESTART FUNCTION REMOTE CONTROLLER 1 4 5 6 7...

Страница 4: ...ised containers e g spray cans If the appliance is used in areas without the possibility of ventilation precautions must be taken to prevent any leaks of refrigerant gas from remaining in the environm...

Страница 5: ...used for any other purpose such as for drying clothes cooling food etc The packaging materials are recyclable and should be disposed of in the separate waste bins Take the air conditioner at the end o...

Страница 6: ...e the air could contain gas oil or sulphur or near sources of heat Do not climb onto or place any heavy or hot objects on top of the appliance Do not leave windows or doors open for long when the air...

Страница 7: ...am of the appliance and may not correspond to the appearance of the units that have been purchased No Description 13 Air outlet grille Terminal block cover 14 gas valve 15 liquid valve 16 11 Indoor un...

Страница 8: ...d Function POWER This symbol appears when the unit is power on 1 2 3 4 5 Temperature display if present Error code 1 Lights up during Timer operation when the air conditioner is operational 2 Displays...

Страница 9: ...t you just need to press the button again a single long beep 4 After 30 minutes in forced operation the air conditioner will automatically start working in 23 cooling mode auto fan speed The FEEL func...

Страница 10: ...witch on off HEALTHY funtion It is a button which controls the ionizer or plasma generator only for inverter models In cooling mode press this button the temperature will increase 2 on the base of set...

Страница 11: ...indicator SIGNAL RECEPTION indicator TIMER OFF indicator TIMER ON indicator AUTO FAN indicator LOW FAN SPEED indicator or MIDDLE FAN SPEED indicator or or HIGH FAN SPEED indicator QUIET or or SLEEP in...

Страница 12: ...e controller toward the Air conditioner 2 Check that there are no objects between the remote control and the Signal receptor in the indoor unit 3 Never leave the remote controller exposed to the rays...

Страница 13: ...ibuted in the room It is possible to position the direction of the air in the optimal In cooling mode orient the flaps in horizontal direction In heating mode orient the flaps downward as the warm air...

Страница 14: ...ioner adjust the temperature 1 the speed 2 and the direction of the air flow 3 by pressing the button indicated HEAT The heating function allows the air conditi oner to heat the room To activate the h...

Страница 15: ...ature with pressing the button or Press TIMER at the second time set the rest time with pressing the button or Press TIMER at the third time confirm the setting then the rest time to next automatical...

Страница 16: ...NG or HEATING This function reduces the humid ity of the air to make the room more comfortable To set the DRY mode Press MODE untill DRY appears in the display An automatic function of alternating coo...

Страница 17: ...dually decreased by 2 during the first 2 hours of operation After 10 hours running in sleep mode the air conditio ner is swicthed off automatically I FEEL MODE FAN SWING SLEEP POWER SLEEP TIMER RUN In...

Страница 18: ...ow 21 Room temperature is below 18 C For T1 Climate condition models For Tropical T3 Climate condition models The unit does not operate immediately if it is turned on after being turned off or after c...

Страница 19: ...r drain pipe 300 500 2000 300 minimum space to be reserved mm showing in the picture 50 0 Installation Diagram INDOOR UNIT OUTDOOR UNIT The purchaser must ensure that the person and or company who is...

Страница 20: ...tapping screws 5 Be sure that the rear panel has been fixed firmly enough to withstand the weight 1 Make the piping hole 55 in the wall at a slight downward slant to the outdoor side 2 Insert the pipi...

Страница 21: ...Place the drain hose below the piping taking care not to create siphons 2 The drain hose must slant downwards to aid drainage 3 Do not bend the drain hose or leave it protruding or twisted and do not...

Страница 22: ...or unit The indoor unit should be installed on a solid wall and fastened securely The following procedure must be observed before co nnecting the pipes and connecting cables decide which is the best p...

Страница 23: ...is not sufficient there will probably be some leakage With excessive tightening torque there will also be some leakage as the flange could be damaged 3 The surest system consists in tightening the co...

Страница 24: ...vacuum pump hose 8 Replace and tighten all the caps on the valves 3 way valve diagram connect to indoor unit open position spindle service port cap Connect to outdoor unit Valve core needle INSTALLAT...

Страница 25: ...erant 1 1 4 6 3 8 9 52 1 4 6 1 4 6 1 4 6 1 4 6 3 8 9 52 3 8 9 52 1 2 12 1 2 12 3 8 9 52 3 8 9 52 5 8 15 88 5 8 15 88 3m 3m 3m 3m 4m 4m 4m R22 MODEL capacity Btu h 7k 9k 12k 15 18k 22 24k 28 30k 36k Li...

Страница 26: ...inal block For different models the wiring diagram may be different Please refer to the wiring diagrams pasted on the indoor unit and outdoor unit respectively On indoor unit the wiring diagram is pas...

Страница 27: ...5mm 2 1 0mm 2 1 5mm 2 1 5mm 2 1 5mm 2 1 5mm 2 1 0mm 2 1 5mm 2 1 0mm 2 1 5mm 2 1 0mm 2 0 75mm 2 1 5mm 2 1 0mm 2 1 5mm 2 1 0mm 2 1 5mm 2 1 5mm 2 1 0mm INVERTER TYPE MODEL capacity Btu h AWG16 AWG18 AWG1...

Страница 28: ...nd lift it till its greatest stroke and then unhooking it from the hinges to make the cleaning easier 2 Clean the indoor unit using a cloth with the water not higher than 40 and neutral soap Never use...

Страница 29: ...his occurs when the air in the room becomes very cold for example in the COOLING or DEHUMIDIFYING DRY modes This noise is made by the expansion or contraction of the front panel due to variations in t...

Страница 30: ......

Страница 31: ......

Страница 32: ...CONTACT DETAILS Glen Dimplex Australia Pty Ltd 1340 Ferntree Gully Road Scoresby VIC 3179 Australia Ph 1300 556 816 http www tclair com au Http www tclair com au...

Отзывы: