TCL TCL-WiredCasCtrl Скачать руководство пользователя страница 5

 

CONTROL PANEL  

 

 

 

 

 

 

 

Sleep 

 

Fresh 

 

Door Card 

 

Defrost 

 

Anti-freeze 

 

Set 

 

Child Lock 

 

Economic 

 

Up/Down 
Swing 

 

Left/Right 
Swing 

 

Degree 
centigrade 

  Fahrenheit 

 

Electric 

 

Error 

 

Water Level 

 

Water 
Pump 
Sign 

 

Current 
Water 
Temperature 

 

Ambient 
Temperature 

 

Set 
Temperature 

 

Compressor 

 

Timer ON 

 

Timer OFF 

 

 

 

 

TIMER BUTTON 

AIR SPEED BUTTON 

AIR MODE BUTTON 

UP BUTTON 

DOWN BUTTON 

ON/OFF BUTTON 

SYMBOL LIST 

Содержание TCL-WiredCasCtrl

Страница 1: ...USER MANUAL WIRED CONTROLLER TCL WiredCasCtrl Read these instructions carefully and keep them safe for future reference...

Страница 2: ...2 CONTENTS SAFETY 2 INTRODUCTION TO WIRED CONTROLLER 4 STARTING UP 5 SETTINGS 6 CLOCK SETTINGS 8 TIMER SETTINGS 9 PARAMETER QUERY SETTINGS 10 TROUBLESHOOTING 12...

Страница 3: ...to experience extremes of temperature 4 Areas exposed to high levels of electromagnetic radiation 5 Any place with high levels of humidity This unit is designed to be installed by a professional air...

Страница 4: ...advice should be sought Maintenance and repair of this product should only be carried out by a qualified professional Keep this manual safe for future reference or for use by a third party The correc...

Страница 5: ...Down Swing Left Right Swing Degree centigrade Fahrenheit Electric Error Water Level Water Pump Sign Current Water Temperature Ambient Temperature Set Temperature Compressor Timer ON Timer OFF TIMER BU...

Страница 6: ...After a buzzer sounds once the liquid crystal will move from left to right and then go off The controller will then exit from self check NOTE All buttons are invalid during the self check Automatic Mo...

Страница 7: ...process FUNCTION SETTING In certain modes you can increase or decrease the temperature by pressing the these buttons increase or decrease the temperature by 0 5 Forced Defrosting On the start up inter...

Страница 8: ...ock is disabled by repeating the process AIR SPEED BUTTON When the wire controller is initially powered on its default air speed is low The icon of low air speed will be displayed If the wire controll...

Страница 9: ...hour use the buttons to cycle the time higher or lower Press the mode button to change to the minutes section and repeat the process until you have your desired time Press mode again to confirm and th...

Страница 10: ...ea 30 150 05 Time Area Hour Temperature at the outlet of evaporator of the indoor unit Current value Temperature Area 30 150 06 Time Area Hour Engineering number of the indoor unit Current value Tempe...

Страница 11: ...ion P3 Time Area Hour Address Setting of Two wire Controller 01 Temperature Display Area 01 Upper computer of RS485 trunk P5 Time Area Hour Power down memory mode Off Temperature Display Area On Valid...

Страница 12: ...rong The E2 of the outdoor unit goes wrong EF The outdoor fan goes wrong The wire controller communication goes wrong EP The temperature switch at the top of compressor goes wrong EU The voltage senso...

Страница 13: ...frequency compressor P3 Outdoor unit protection P4 Exhaust high temperature protection Variable frequency compressor or Slave F3 P5 Under cooling protection in the cooling mode Indoor unit coil tempe...

Страница 14: ...tment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment to partici...

Отзывы: