 When  the  parameter  value  flashes

, press the [▲] or [▼] buttons to change the 

“Parameter Value”; press the [Mode]  button to save the “Parameter Value” and 
return to the “Parameter Code” flashing interface. 

Parameter Code

 

Query the Current 

Parameter

 

Query Range

 

Parameter 

Code

 

Area 

Display

 

Parameter Name

 

Value 

to 

Query

 

Area Display

 

P1

 

Time 

Area-Hour

 

The indoor unit 

corresponding to 

the

 

wire controller is 

the

 

indoor unit in the 

master mode

 

SL

 

Temperature 
Display Area

 

SL: From the 

indoor unit

 

P2

 

Time 

Area-Hour

 

Clearing Away 

the

 

Master Indoor 

Unit from the Set

 

00

 

Temperature 
Display Area

 

00: No action

 

P3

 

Time 

Area-Hour

 

Address Setting 

of Two-wire 

Controller

 

01

 

Temperature 
Display Area

 

01: Upper 

computer of RS485 

trunk

 

P5

 

Time 

Area-Hour

 

Power-down 

memory mode

 

Off

 

Temperature 
Display Area

 

On: Valid

 

on

 

Off: Invalid

 

P6

 

Time 

Area-Hour

 

Temperature Unit 

Conversion

 

 

Temperature 
Display Area

 

C: degree 

centigrade

 

 

P7

 

Time 

Area-Hour

 

Selection of 

Ambient

 

Temperature 

Sensing

 

Bag

 

IL

 

Temperature 
Display Area

 

/

 

P8

 

Time 

Area-Hour

 

Modification 

Value of Return-

air

 

Temperature 
Sensing Bag

 

00

 

Temperature 
Display Area

 

-15

~15

 

P9

 

Time 

Area-Hour

 

Modification 

Value of Return-

air

 

Temperature 
Sensing Bag

 

00

 

Temperature 
Display Area

 

-15

~15

 

PF

 

Time 

Area-Hour

 

Thermal 

Aggregation 

Prevention

 

00

 

Temperature 
Display Area

 

00~60

 

PH

 

Time 

Area-Hour

 

Maximum 

Defrosting 

Duration

 

15

 

Temperature 
Display Area

 

00~20

 

Содержание TCL-WiredCasCtrl

Страница 1: ...USER MANUAL WIRED CONTROLLER TCL WiredCasCtrl Read these instructions carefully and keep them safe for future reference...

Страница 2: ...2 CONTENTS SAFETY 2 INTRODUCTION TO WIRED CONTROLLER 4 STARTING UP 5 SETTINGS 6 CLOCK SETTINGS 8 TIMER SETTINGS 9 PARAMETER QUERY SETTINGS 10 TROUBLESHOOTING 12...

Страница 3: ...to experience extremes of temperature 4 Areas exposed to high levels of electromagnetic radiation 5 Any place with high levels of humidity This unit is designed to be installed by a professional air...

Страница 4: ...advice should be sought Maintenance and repair of this product should only be carried out by a qualified professional Keep this manual safe for future reference or for use by a third party The correc...

Страница 5: ...Down Swing Left Right Swing Degree centigrade Fahrenheit Electric Error Water Level Water Pump Sign Current Water Temperature Ambient Temperature Set Temperature Compressor Timer ON Timer OFF TIMER BU...

Страница 6: ...After a buzzer sounds once the liquid crystal will move from left to right and then go off The controller will then exit from self check NOTE All buttons are invalid during the self check Automatic Mo...

Страница 7: ...process FUNCTION SETTING In certain modes you can increase or decrease the temperature by pressing the these buttons increase or decrease the temperature by 0 5 Forced Defrosting On the start up inter...

Страница 8: ...ock is disabled by repeating the process AIR SPEED BUTTON When the wire controller is initially powered on its default air speed is low The icon of low air speed will be displayed If the wire controll...

Страница 9: ...hour use the buttons to cycle the time higher or lower Press the mode button to change to the minutes section and repeat the process until you have your desired time Press mode again to confirm and th...

Страница 10: ...ea 30 150 05 Time Area Hour Temperature at the outlet of evaporator of the indoor unit Current value Temperature Area 30 150 06 Time Area Hour Engineering number of the indoor unit Current value Tempe...

Страница 11: ...ion P3 Time Area Hour Address Setting of Two wire Controller 01 Temperature Display Area 01 Upper computer of RS485 trunk P5 Time Area Hour Power down memory mode Off Temperature Display Area On Valid...

Страница 12: ...rong The E2 of the outdoor unit goes wrong EF The outdoor fan goes wrong The wire controller communication goes wrong EP The temperature switch at the top of compressor goes wrong EU The voltage senso...

Страница 13: ...frequency compressor P3 Outdoor unit protection P4 Exhaust high temperature protection Variable frequency compressor or Slave F3 P5 Under cooling protection in the cooling mode Indoor unit coil tempe...

Страница 14: ...tment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment to partici...

Отзывы: