TCL iQool-C2MS12K12K Скачать руководство пользователя страница 1

 

 

 

USER AND INSTALLATION 

MANUAL

 

 
 

SMART WIFI CONTROLLED 

CEILING MOUNTED 

MULTI CASSETTE AIR CONDITIONER

 

 

Thank you for choosing a TCL Air Conditioner 

Please read this user manual before using this innovative  

Air Conditioner and keep it safe for future reference. 

Double 

iQool-C2MS12K12K   

2 x 12,000 BTU Cassettes 

Triple 

iQool-C3MS9K9K9K   

3 x 9,000 BTU Cassettes 

Содержание iQool-C2MS12K12K

Страница 1: ...SETTE AIR CONDITIONER Thank you for choosing a TCL Air Conditioner Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Double iQool C2MS12K1...

Страница 2: ...E QUICK CONNECTION 17 CONNECTING USING AP MODE ALTERNATIVE METHOD 18 USING THE TIMER FUNCTION 21 MORE SETTINGS 22 MAINTENANCE 23 END OF SEASON 24 START OF SEASON 24 REPLACING THE BATTERIES 24 INSTALLA...

Страница 3: ...d outdoor units must be hardwired by a qualified electrician Never operate this appliance if the cord is damaged Ensure the power cord is not stretched or exposed to sharp objects or edges A damaged s...

Страница 4: ...damage to the unit and may invalidate the warranty In case of refrigerant leak the stress meter will stop the operation of unit a qualified F gas engineer should be contacted to arrange service The r...

Страница 5: ...5 Liquid line 6 Compressor 7 Condenser 8 Condenser Fan HEAT PUMP MODE The system operates in reverse the condenser works as an evaporator the evaporator as a condenser warm air is blown into the room...

Страница 6: ...R UNIT OUTDOOR UNIT 1 Air Outlet 2 Refrigerant pipe junction 3 Uplift Pump 4 Drainage Pipe 5 Air Return 6 Filter 7 Remote Control 8 Louvre for airflow 9 Refrigerant pipes 10 Interconnecting Cable 11 O...

Страница 7: ...7 PANEL Do not block the air inlets outlets on the cassette as this will reduce the units performance and may lead to damage...

Страница 8: ...t the timer 6 Sleep Press to activate the SLEEP function 7 Eco In cooling mode press to increase the set temperature by 2oC In heating mode press to decrease the set temperature by 2oC 8 Mode Press to...

Страница 9: ...batteries are inserted the cool and heat symbols will alternate on the screen of the remote For HEATING AND COOLING press any button while the heat symbol is shown If the remote is set up for the wro...

Страница 10: ...e best performance The operation logic is as below Ambient Temperature Operation Mode Auto Temperature 20 C Heating 23 C 20 C 26 C Dry 18 C 26 C Cool 23 C 3 Use the FAN button to set the fan speed TIM...

Страница 11: ...vels SWING 1 Press the SWING buttons to control the fan direction 2 The controls the horizontal air movement up down 3 The button is not activated on this model and the horizontal direction of the air...

Страница 12: ...and or use of the room where the air conditioner is installed Strong sunlight and the presence of people lights or equipment creates an additional heat load Normal living spaces require about 350 Btu...

Страница 13: ...ir conditioner requires a good signal during the setup process Your air conditioner is designed to be connected to a 2 4ghz network and the connection is set up using the TCL SMART LIFE app We would a...

Страница 14: ...ill need to be registered Click on the Register button to enter the registration screen The account can be created by using either the default option of an email address or alternatively by SMS messag...

Страница 15: ...our new password in the box below Please note the password should be at least 6 characters and include letters and numbers Then press the confirm button to log in FORGOTTEN PASSWORD Should the passwor...

Страница 16: ...e device within the app and as such the following connection process should be repeated for each indoor unit CHANGING BETWEEN CONNECTION TYPES To change the unit between the two connection types quick...

Страница 17: ...your Wifi router from the drop down list and enter the password Please note the password is case sensitive before pressing next The app will automatically upload the connection information to the air...

Страница 18: ...isplayed 2 Press on the AP Mode button in the top right of the screen to change the app to AP mode connection 3 Select your Wifi router from the drop down list and enter the password Please note the p...

Страница 19: ...itioner once the connection is completed a message will be displayed to confirm On this page there is the option to rename the air conditioner to something more relevant If the connection fails please...

Страница 20: ...e desired temperature The tabs on the bottom of the screen should be used to change other settings Mode Allows the operating mode to be changed between Feel Heat Dry Cool and Fan Speed Allows the fan...

Страница 21: ...e bottom of the screen If there is a timer already programmed that you would like to amend press and hold the timer which requires amendment OFF TIMER 1 Select Timer Off 2 Set the time the air conditi...

Страница 22: ...the main screen the three dots in the top right hand corner give you access to the settings options for the app This a number of extra options for modifying the name of the air conditioner and removi...

Страница 23: ...at a 45 angle to the unit and lift to unhook from the rear of the panel 4 The filter can then be removed from the grill for cleaning CLEANING THE FILTERS Clean the air filter with a vacuum cleaner or...

Страница 24: ...Check that the condensation outlet drains properly and there is no dirt or organic blockage otherwise leakage may occur Install 2 AAA batteries in the remote control Check that the wiring between the...

Страница 25: ...When the power cord is damaged replacement work shall be performed by authorized personnel only Installation work must be performed in accordance with all European national and or local directives and...

Страница 26: ...The height of the installed unit should be more than 200cm from the floor The air conditioner must not be installed in a wet environment such as a bathroom shower or swimming pool etc OUTDOOR UNIT PO...

Страница 27: ...ols Electric Drill Hammer Screwdrivers Tape Measure Core Hole Cutter Spirit Level Number 14 7mm Masonry Drill Pencil and Chalk 4 x M10 threaded rods Small Stepladder 7mm Wall Plugs Protective Glasses...

Страница 28: ...lect the installation location taking consideration of the following 1 Route of the pipework wiring 2 Access to the upper parts of the unit for connection of the pipework wiring after hanging the unit...

Страница 29: ...t of the ceiling around the opening may be necessary If beams require cutting to accommodate the unit the remaining beams around the area should be reinforced to compensate for the extra weight they a...

Страница 30: ...he ceiling Overhang the cassette unit above the ceiling slotting the bars into the brackets on the cassette unit and tightening into position ensuring that the unit is level Hanging Bolt Nut Up Side G...

Страница 31: ...from the unit The flexible hose must be mounted horizontally We advise on the following materials to be used Drain Pipe Polyvinyl chloride pipe 32mm outer diameter Heat Insulation Foamed polyethylene...

Страница 32: ...initially be visually checked Once visually checked an operation test can be conducted 1 Ensure power is not connected to the unit 2 Remove the water tank cover and insert 600ml of water ensuring that...

Страница 33: ...on the electrical box with the one on the panel before loosely fastening with the M6 bolts 4 Connect the cables for the step motors and display panel to the cassette following the wiring diagram provi...

Страница 34: ...level If the unit is installed on the wall or at the rooftop the supports have to be firmly fixed so as to resist earthquakes or strong wind Dimensions for parallel units installations 300mm 1 min CO...

Страница 35: ...only be performed by a professional F Gas engineer for the additional gas amount see the below FLARING THE PIPES 1 Cut the refrigerant pipe to the correct length using a pipe cutter 2 Ensure the end...

Страница 36: ...ake the packed soft pipes vertical before extending Please do not extend only one side of the packed soft pipes Please make use of semicircle pulley to keep the allowed bending angle Extreme bending c...

Страница 37: ...elow 1 Remove the dust caps from the indoor and outdoor units and the connecting pipe 2 Align the joint of the connecting pipe between the indoor and outdoor and tighten the connecting nut by hand to...

Страница 38: ...n time for vacuuming is about 10 minutes When the desired vacuum is reached close the low pressure valve on the manifold and stop the vacuum pump 3 Disconnect the service hoses and fit the cap to the...

Страница 39: ...e the unit and invalidate the warranty Secure the wires and replace the cover before operating the unit The appliance should be installed in accordance with national wiring regulations If the supply c...

Страница 40: ...The diagrams provided in the manual are for guidance only Due to continual product development the diagrams provided on the units themselves should be followed where any discrepancies are found Conne...

Страница 41: ...41 iQool C3MS9K9K9K Outdoor PCB iQool C2MS12K12K Outdoor PCB Outdoor PCB Outdoor PCB...

Страница 42: ...s in temperature and does not indicate a problem Insufficient airflow either hot or cold Inappropriate temperature setting Air inlet or outlet of indoor or outdoor unit has been blocked Air filter is...

Страница 43: ...fault EC Outdoor Communication fault EE Outdoor EEPROM fault EF Outdoor fan motor fault DC motor EH Outdoor suction temperature sensor fault En Outdoor gas pipe temperature sensor fault EP Temp switch...

Страница 44: ...tage lower voltage 3 Overcurrent 4 Exhaust over temperature protection 5 Outdoor coil over temperature protection 6 Drive fault and protection V1 VP1 7 Communication fault with indoor unit 8 Compresso...

Страница 45: ...s indicates that the AC has been reset and the mobile device has lost contact with the AC Reconnect the device following the above instructions If this fails delete the AC from your devices list and s...

Страница 46: ...60 Balance point temperature heating oC 7 7 Min outdoor operating temperature oC 15 15 Thermostat off mode W 161 129 Standby mode W 6 4 Off mode W 0 0 Annual consumption kW 470 2733 352 2098 Number of...

Страница 47: ...verned by F Gas regulations The gas must be handled by qualified F Gas engineers APPENDIX Disposal Do not dispose this product as unsorted municipal waste Collection of such waste must be handled sepa...

Страница 48: ...ur only We recommend that you note the details of your purchase below and retain your original proof of purchase receipt with this manual Keep these documents safe in the event of a warranty claim Pur...

Отзывы: