9
HW & installation
I/O Cards
I/O cards MUST be mounted in slots A, B and C
consecutively starting in slot A. Dip-switches must be
correctly set on the I/O cards.
For DSP cards all jumpers must be set to off (up position)
For I/O cards jumper 2 must be set to on (down-position)
To install a DSP or I/O expansion card in your Frame
.
1 Switch OFF the unit and disconnect the mains power
cord.
2. Remove the DUM-1 option plate(s) or module by
loosening the 2 screws.
3. Insert the card gently and mount the two screws.
Static Electricity
As all computer hardware can be sensitive to static
electricity, certain precautions must be taken to protect it
from damage during storage and handling.
Storage
Non-mounted modules should always be stored in
anti-static shielded bags.
General Handling
When inserting or removing any modules, avoid touching
the circuit board by handling only the rear panel of the
module. To minimize the static potentials that can cause
damage to the electronic circuits, you should observe
precautionary grounding techniques such as touching
a grounded DB4/DB8 Mainframe immediately before
inserting modules.
Removing Modules
Before removing any card from your Mainframe, unplug
the mains power cable. Unplug all other connections from
the module before unscrewing the two screws securing the
module in the Mainframe. When removing a module from a
Mainframe, the card should be mounted directly in another
Mainframe or placed in an anti-static shielded bag.
Mounting Modules
Before mounting modules in your DB8/DB4, unplug the
mains power cable. Remove the dummy-panel or original
module from the slot where you want to install the module.
The module should then be removed from the shielded bag
and mounted directly in the Mainframe by handling the rear
panel of the module only. Avoid touching any components
on the PCB-Board.
Caution!
The servicing instructions are for
use by qualified personnel only. To
reduce the risk of electric shock do
not perform any servicing other than
that in the operation instructions
unless you are qualified to do so.
DUAL POWER
INLETS
2
1
LAN
ETHERNET
ON
OFF
GROUNDLIFT
100-240V
AC
50-60Hz 60W
~
SERIAL NO.
CAUTION
SHOCK HAZARD DO NOT OPEN
AVIS: RISIQUE DE CHOC
ELECTRIQUE NE PAS OUVRIR
TYPE:M6000F20
MADE IN DENMARK
US
C
R
THIS CLASS B DIGITAL DEVICE MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIONS
AND COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION SUBJECT TO CONDITIONS STATED IN THE MANUAL.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
MIDI IN
MIDI THRU
MIDI OUT
REMOTE
SMPTE
PEDAL
IO-6000 SDI HD
AUDIO EMBEDDER / DE-EMBEDDER
B
A
individually buffered
SDI
inputs
IEEE
-1394
bypass
relay
SDI
outputs
DSP6000 SDI
AUDIO EMBEDDER / DE-EMBEDDER
B
A
individually buffered
SDI
inputs
IEEE
-1394
bypass
relay
SDI
outputs
Dsp anD I/O expansIOn CarDs