EMC/EMI

This equipment has been tested and found to comply with the limits for a Class B
Digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful
interference in residential installations. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

For Customers in Canada:

This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

EMC / EMI & CERTIFICATE OF CONFORMITY

Certificate of Conformity

TC Electronic A/S, Sindalsvej 34, 8240 Risskov, Denmark,
hereby declares on own responsibility that the following
product:

Classic450

– Bass amplifier

that is covered by this certificate and marked with CE-label
conforms with following standards:

EN 60065

Safety requirements for mains operated 

(IEC 60065) electronic and related apparatus for

household and similar general use

EN 55103-1 Product family standard for audio,

video, audio-visual and entertainment
lighting control apparatus for
professional use. Part 1: Emission.

EN 55103-2 Product family standard for audio,

video, audio-visual and entertainment
lighting control apparatus for
professional use. Part 2: Immunity.

With reference to regulations in following directives:
2006/95/EC, 89/336/EEC

Issued in Risskov, June 2009
Anders Faurskov
Chief Executive Officer

Содержание Classic 450

Страница 1: ...Classic450 USER S MANUAL...

Страница 2: ......

Страница 3: ...ged in any way such as when a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus or if the apparatus has been exposed to rain or moisture does not o...

Страница 4: ...nt from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help For Customers in Canada This Class B digital apparatus complies with Canadian ICES 003...

Страница 5: ...Introduction 4 Quick Setup Guide 5 OPERATION Front Panel 6 Rear Panel 9 APPENDIX General Protection mode 11 Heat Protection mode 11 Technical Specifications 13 3 EN TABLE OF CONTENTS TC Electronic Sin...

Страница 6: ...ile tone control section This sound palette sits on the solid foundation of TC Electronic s Tubetone and multiband SpectraComp technologies TubeTone emulates every characteristic of a tube pre amp and...

Страница 7: ...speaker cable included so if you have bought a RS cabinet you are all set to go You can connect up to three RS cabinets or any other two 8 Ohm cabinets of another brand to the amplifier The minimum lo...

Страница 8: ...ng 4 SPECTRACOMP Turn this knob to set the desired amount of SpectraComp compression SpectraComp uses a so called spectral or multi band approach to compression allowing for individual compression of...

Страница 9: ...hapes the entire signal Typically the result is that either the G string is not compressed at all or that just when the G string starts to sound right the low E string is compressed too strongly In ot...

Страница 10: ...amount of both the preamp and the power amp tube simulation 7 MASTER Use the MASTER level knob to set the overall output level of the amp Please note that you should set the input level using the GAI...

Страница 11: ...assic450 on a tour The ground pin of the power supply unit PSU must be connected in order to avoid voltage differences between e g the PA and the Classic450 2 SPEAKER OUT Use the SPEAKER OUT combo con...

Страница 12: ...ps 5 PRE POST switch The PRE POST switch determines the position of the tap point for the LINE DRIVER OUT In pre position the signal is tapped right after the input gain control In post position the s...

Страница 13: ...it on again If protection mode is still indicated you will have to send the Classic450 to a qualified service center for inspection Heat Protection Mode If the Peak LED lights up while the amp is in G...

Страница 14: ...12 APPENDIX SIGNAL FLOW...

Страница 15: ...in 12 24 dB Shelving type 3 dB slope 0 to 10 Tube amp Recreation 3 band Spectral Compression Universal 100 to 240V 50 60 Hz 80 w 1 8 Power Combined Speakon jack 450 W 800 W Peak 4 Ohm Transformer Bala...

Страница 16: ......

Отзывы: