TC Electronic Classic 450 Скачать руководство пользователя страница 3

a

EN

1 Read these instructions.
2 Keep these instructions.
3 Heed all warnings.
4 Follow all instructions.
5 Do not use this apparatus near water.
6 Clean only with dry cloth.
7 Do not block any ventilation openings. Install in accordance with the

manufacturer’s instructions.

8 Do not install near heat sources such as radiators, heat registers, stoves, or other

apparatus (including amplifiers) that produce heat.

9 Do not defeat the safety purpose of the polarized or grounding-type plug. A

polarized plug has two blades with one wider than the other. A grounding type plug
has two blades and a third grounding prong. The wide blade or the third prong are
provided for your safety. If the provided plug does not fit into your outlet, consult an
electrician for replacement of the obsolete outlet.

10 Protect the power cord from being walked on or pinched, particularly at plugs,

convenience receptacles, and the point where they exit from the apparatus.

11 Only use attachments/accessories specified by the manufacturer.
12

12

Use only with the cart, stand, tripod, bracket,

or table specified by the manufacturer or sold with the apparatus. When
a cart is used, be careful when moving the cart/apparatus combination
to avoid injury from tip-over.
13

Unplug this apparatus during lightning storms or when not

in use for longer periods of time.

14 Refer all servicing to qualified service personnel. Servicing is required when the

apparatus has been damaged in any way, such as when a power supply cord or
plug is damaged, liquid has been spilled or objects have fallen into the apparatus,
or if the apparatus has been exposed to rain or moisture, does not operate
normally or has been dropped.

This equipment should be installed near the socket outlet and disconnection of the
device should be easily accessible.

To completely disconnect from AC mains, disconnect the power supply cord from
the AC receptacle.

The mains plug of the power supply shall remain readily operable.

Do not install in a confined space.

Do not open the unit – risk of electric shock inside!

Caution:

You are cautioned that any change or modifications not expressively approved in this
manual could void your authority to operate this equipment.

Service

There are no user-serviceable parts inside.

All service must be performed by qualified personnel.

IMPORTANT SAFETY INSTRUCTIONS

Voltage 

Line plug according to standard

110-125V

UL817 and CSA C22.2 no 42.

220-230V

CEE 7 page VII, SR section 
107-2-D1/IEC 83 page C4.

240V

BS 1363 of 1984. 
Specification for 13A fused plugs and switched 
and unswitched socket outlets.

Warning!

To reduce the risk of fire or electrical shock, do not expose this equipment to
dripping or splashing and ensure that no objects filled with liquids, such as vases,
are placed on it.

This apparatus must be earthed.

Use a three wire grounding type line cord like the one supplied with the product.

Be advised that different operating voltages require the use of different types of line
cord and attachment plugs.

Check the voltage in your area and use the correct type. Please refer to the
following table:

Содержание Classic 450

Страница 1: ...Classic450 USER S MANUAL...

Страница 2: ......

Страница 3: ...ged in any way such as when a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus or if the apparatus has been exposed to rain or moisture does not o...

Страница 4: ...nt from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help For Customers in Canada This Class B digital apparatus complies with Canadian ICES 003...

Страница 5: ...Introduction 4 Quick Setup Guide 5 OPERATION Front Panel 6 Rear Panel 9 APPENDIX General Protection mode 11 Heat Protection mode 11 Technical Specifications 13 3 EN TABLE OF CONTENTS TC Electronic Sin...

Страница 6: ...ile tone control section This sound palette sits on the solid foundation of TC Electronic s Tubetone and multiband SpectraComp technologies TubeTone emulates every characteristic of a tube pre amp and...

Страница 7: ...speaker cable included so if you have bought a RS cabinet you are all set to go You can connect up to three RS cabinets or any other two 8 Ohm cabinets of another brand to the amplifier The minimum lo...

Страница 8: ...ng 4 SPECTRACOMP Turn this knob to set the desired amount of SpectraComp compression SpectraComp uses a so called spectral or multi band approach to compression allowing for individual compression of...

Страница 9: ...hapes the entire signal Typically the result is that either the G string is not compressed at all or that just when the G string starts to sound right the low E string is compressed too strongly In ot...

Страница 10: ...amount of both the preamp and the power amp tube simulation 7 MASTER Use the MASTER level knob to set the overall output level of the amp Please note that you should set the input level using the GAI...

Страница 11: ...assic450 on a tour The ground pin of the power supply unit PSU must be connected in order to avoid voltage differences between e g the PA and the Classic450 2 SPEAKER OUT Use the SPEAKER OUT combo con...

Страница 12: ...ps 5 PRE POST switch The PRE POST switch determines the position of the tap point for the LINE DRIVER OUT In pre position the signal is tapped right after the input gain control In post position the s...

Страница 13: ...it on again If protection mode is still indicated you will have to send the Classic450 to a qualified service center for inspection Heat Protection Mode If the Peak LED lights up while the amp is in G...

Страница 14: ...12 APPENDIX SIGNAL FLOW...

Страница 15: ...in 12 24 dB Shelving type 3 dB slope 0 to 10 Tube amp Recreation 3 band Spectral Compression Universal 100 to 240V 50 60 Hz 80 w 1 8 Power Combined Speakon jack 450 W 800 W Peak 4 Ohm Transformer Bala...

Страница 16: ......

Отзывы: