background image

TC8927 Rev 1.0     User Manual

   

A-1

Appendix A

19” Rack Mount Card Cage

A.1

Features

1U height (1.75")

Universal Power Supply Accepts 90V to 264V AC and 47 to 63 Hz AC

Standard Power Supply is 12VDC, Optional 24VDC, -48VDC, 125VDC, or 
AC Power Supply Available

Over Load & Short Circuit Protection

A.2

Description

This 1U "Pizza Box" Rack Mount Card Cages hold up to 2 single multiplexer type 
cards.

It operates with one power supply. The AC power supply automatically adjusts for 
90V to 264V AC input and 47 to 63 Hz operation. The DC power supply accepts 
24VDC, -48VDC, or 125VDC input (Optional).

This 1U rack assembly is 19" wide by 1.75" high, and is 9" deep.

A.3

Chassis Ground

The Stand alone and Rack mount chassis provide a connection point for chassis 
ground with a dedicated chassis ground screw and lock washer. The chassis ground 
screw is located on the rear side of the chassis. This chassis ground connection point 
is available in case chassis ground is taken into design consideration by the end user.

µ

FP

µ

FP

µ

FP

µ

FP

1U Chassis

Содержание TC8927

Страница 1: ...TC8927 6 2 Ch Paging System w Dry Contact User Manual MNL 89270 01 00...

Страница 2: ...out of errors in this document The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions We appreciate any suggested improveme...

Страница 3: ...symbols are used in Caution Warning and Danger notes Symbol Meaning Pinching or crushing hazard Electrical hazard Equipment alert be careful of damage from static electricity General alert used for a...

Страница 4: ...2 2 5 Dry Contact Alarm Relay DCAR 2 2 2 6 System Start Up 2 2 2 7 System Configuration 2 2 2 7 1 Front Panel Analog Pin Assignments 2 3 2 7 2 Rear Panel 2 3 2 7 3 Electrical Signal Interface Connecti...

Страница 5: ...he TC8927 bridges broadcasts analog audio and dry contact from a central location to remote sites An incoming analog dry contact signal coming into the primary host port will be broadcast to 6 slave p...

Страница 6: ...Chapter 1 Introduction Product Description 1 2 TC8927 Rev 1 0 User Manual Figure 1 2 TC8927 Front Panel LED Definitions...

Страница 7: ...Channel Inputs as Host Ports 6 Channel Outputs as Slave Ports Modular Design with 8 Channels per Module 64K Full Bandwidth Voice Transport Passes All Tones used for FSK EIA Tone Control Remote and Pag...

Страница 8: ...ev 1 0 User Manual LEDs for Analog Volume Alarm Status Channel Release Tone and Loopback 1 2 2 Applications The TC8927 bridges broadcasts analog audio and dry contact from a central location to remote...

Страница 9: ...nector RJ 11 Impedance 600 System Visual Indicators System PWR A PWR B Vcc ALM Paging P R Tone Channel Status TX 1 each Ports 1 8 RX 1 each Ports 1 8 Diagnostic Functions Local Loopback Power Source S...

Страница 10: ...Chapter 1 Introduction Specifications 1 6 TC8927 Rev 1 0 User Manual Physical Rack mount 1U Pizza Box Height 4 3 cm 1 7 Width 48 3 cm 19 Depth 26 7 cm 10 5...

Страница 11: ...removed from the containers 2 3 Equipment Location The TC8927 should be located in an area that provides adequate light work space and ventilation IMPORTANT Any claims concerning shipping damage shou...

Страница 12: ...O Normal Open configuration the relay will close if the unit loses power completely or the Alarm is on The relay remains open during normal operation When used in NC Normal Close configuration the rel...

Страница 13: ...Manual 2 3 2 7 1 Front Panel Analog Pin Assignments Figure 2 1 TC8927 Front Panel Analog Dry Contact Connectors 2 7 2 Rear Panel Figure 2 2 TC8927 Rear Panel Main Extension 8 RJ 11 Connectors for Ana...

Страница 14: ...alog signals are received on the Input pins and looped back to the Output pins on the TC8927 1 The TX LED will be flashing green for that particular channel being tested and the ALM alarm LED will fla...

Страница 15: ...to setup the number of Channels Off Down is for 8 channels mode On Up is for 16 channels mode T1 T2 Channel Release Time These switches are used to set the channel release time stop broadcasting after...

Страница 16: ...ront panel of the TC8927 600 Analog Connections RJ 11 600 Analog 4 Wire Port Pin Assignment Host Ports 1 Detector Input RJ 11 Jack 2 Output RING 3 Input RING 4 Input TIP 5 Output TIP 6 Detector Input...

Страница 17: ...5 2 All LEDs are OFF If no LEDs are lit on the unit check the DC power supply connector plug and or the power source If the problem persists contact the Technical Support Department at TC Communicati...

Страница 18: ...ower supply The AC power supply automatically adjusts for 90V to 264V AC input and 47 to 63 Hz operation The DC power supply accepts 24VDC 48VDC or 125VDC input Optional This 1U rack assembly is 19 wi...

Страница 19: ...shipment unless goods have been subject to misuse neglect altered or destroyed serial number labels accidents damages caused in whole or in part to accident lightning power surge floods fires earthqu...

Страница 20: ...re returned for repair retest B 1 2 Limitation of Liability 1 In no event shall the total liability of T C COMMUNICATIONS INC to purchaser and or end user for all damages including but not limited to...

Страница 21: ...ual Index 1 C cabling 2 2 D DCAR 2 2 E electrical 5 1 environmental requirements 2 1 F front panel 2 2 M mechanical installation 2 2 P power unit 2 2 S specifications 1 5 T troubleshooting 5 1 U unpac...