Chapter 7 - Specifications .......................................................................................... 32

Electrical ............................................................................................................................................32

Optical ................................................................................................................................................32

Visual Indicators ...............................................................................................................................32
Alarm ..................................................................................................................................................32

Power Sources .................................................................................................................................32

Temperature ......................................................................................................................................32
Physical (Standalone/Rackmount Unit) .......................................................................................32

Appendix - A .............................................................................................................. 33

Return Policy ....................................................................................................................................33

Warranty ............................................................................................................................................33

Appendix - B.............................................................................................................. 34

Setting the Self-Healing Ring IDs on the TC3720's ...................................................................34

Содержание TC3720

Страница 1: ...ny specifica tion TC Communications Inc reserves the right to change or modify the contents of this manual at any time without prior notification TC3720 Self Healing Industrial Ethernet Fiber Optic Sw...

Страница 2: ...ware Configuration 11 Self Healing Ring SHR ID Setting 11 Hardware SHR ID Settings 11 Examples To Set the SHR ID 11 Bench Test 12 Configuring the Master Unit 12 Configuring the Slave Units 13 Chapter...

Страница 3: ...fications 32 Electrical 32 Optical 32 Visual Indicators 32 Alarm 32 Power Sources 32 Temperature 32 Physical Standalone Rackmount Unit 32 Appendix A 33 Return Policy 33 Warranty 33 Appendix B 34 Setti...

Страница 4: ...720 offers a sophisticated Self Healing Ring scheme Fault conditions are detected on both Tx and Rx upstream and downstream of each unit and automatically re routed to maintain Ring integrity A Web ba...

Страница 5: ...ength 1310nm Single Mode LASER Connector ST FC SC Single Mode 1310nm 75km Model Transmitter FP Laser typical Launch Power 3 to 2dBm 1310nm 9 125 m Receiver PIN Diode typical Sensitivity 36 0 dBm 1310n...

Страница 6: ...typical Sensitivity 33 0 dBm 1310nm 1550nm 9 125 m Optic saturation level 3 dBm Loss Budget 1310nm 1550nm Single Mode 9 125 m 29 dB Distance 1310nm 1550nm Single Mode 9 125 m up to 50km distance Wavel...

Страница 7: ...Off when connection is good Speed of F1 or F2 is fixed to 100Mb sec when Ethernet Activity at the fiber optic port is detected when no optical link is established Dip Switches Self Healing Ring Up Dis...

Страница 8: ...r Slave Not Used Serial DB9 port 9600 8 N 1 9600 Baud 8 data bits no parity 1 stop bit Reset Button Used to reset the unit back to the current hardware settings 1 Unplug the power to the unit 2 Push a...

Страница 9: ...in power redundancy feature While only one connection is required to power the unit both connectors can be used simultaneously When power redundancy is utilized both power A B share the load If one p...

Страница 10: ...The units are configured through the Management port RJ 45 connector on the rear panel of the switches See Chapter 4 Software Configuration Note If you want to configure the IP address username or pas...

Страница 11: ...tion ID 2 Set dip switch 2 to the down position and the rest to the up position ID 3 Set dip switches 1 and 2 to the down position and the rest to the up position ID 4 Set dip switch 3 to down the pos...

Страница 12: ...the down position 2 Select the fiber ports to form the SHR set the F1 1X and F2 2X dip switches on the front panel to the up position 3 Enable the MSTR dip switch on the rear panel to the down positio...

Страница 13: ...panel to the down position 7 The MSTR SLVE LED on the front panel should be off Repeat steps 1 5 for the remaining slave units After completing the configurations for the Master and Slave units 1 Inte...

Страница 14: ...at of your PC refer to Console Port Settings on page 26 To configure the TC3720 simply enter the default IP address of the TC3720 in the Web browser s address box For example if the unit is set to Mas...

Страница 15: ...ort SHR ID SHR Master ID Port Settings Copper Ports 1 6 Port State Speed Duplex Ingress Limit Egress Limit Flow Control Fiber Ports F1 and F2 Port State Ingress Limit Egress Limit Flow Control SHR Sta...

Страница 16: ...dow as in figure 5 and you can begin the configurations You may change the values names of the Switch Name Location or Contact fields as you like or you can leave as they appear The location field wil...

Страница 17: ...e All SHR ports of the switches on the ring should be kept the same SHR ID Any integer All units in a ring must have a unique SHR ID SHR Master ID All units in a ring must be set to the same SHR Maste...

Страница 18: ...ngs link on the left side of the page to configure either the RJ 45 Ports 1 through 6 or the Fiber Ports F1 or F2 settings After clicking the Port Settings link you will see the following window shown...

Страница 19: ...te limiting for inbound traffic data going into the TC3720 port The default value of the rate limit is None no limit on the inbound traffic The rate limit can be set to 128K 256K 512K 1M 2M 4M 8M 16M...

Страница 20: ...20 TC3720 User s Manual Rev 1 5 Software Configuration Continue Figure 9 TC3720 Port Settings Dialog Box Ingress Limit Rate limiting for inbound traffic...

Страница 21: ...hen you click on this button you will see all the units in the SHR link working under normal conditions as in figure 10 Note When there is a fiber breakage in the link there will be a star in front of...

Страница 22: ...reakage in the SHR link The particular units with broken fiber links will be displayed with a star in front of its SHR ID s To view the details on the fiber breakage click on the Error Report button a...

Страница 23: ...how the switch ID related fiber port IP address and Location Field where the fiber breakage occurs two units will be displayed for each broken link The Master will display information on all the units...

Страница 24: ...name and or password you can do so by following the steps below 1 Enter the new username and or password and click Apply You will then see a window as in figure 14 on page 25 Click reset to save all t...

Страница 25: ...25 TC3720 User s Manual Rev 1 5 Figure 14 TC3720 New Settings Saved Window Figure 15 TC3720 Login with New Settings...

Страница 26: ...ype password after the Password prompt Note You will not see the password characters when typed 8 When password has being entered correctly you will see Password Accepted 9 At this point you can conti...

Страница 27: ...t ip 192 168 254 123 Set netmask Set Unit s Netmask E g Set netmask 255 255 255 0 Set gateway Set Unit s Gateway IP E g Set gateway 192 168 254 1 Set username Set login username E g Set username john1...

Страница 28: ...28 TC3720 User s Manual Rev 1 5 Show Command The show command will show the current IP settings of the TC3720 unit Figure 18 TC3720 s Show Command...

Страница 29: ...9 TC3720 User s Manual Rev 1 5 Telnet Settings You can also use Telnet to set the IP configuration username and password Note The Telnet default timeout is two minutes Figure 19 TC3720 s Telnet Settin...

Страница 30: ...y changes Contact your network administrator if you are unsure about the settings Improper settings may result in disruption of the existing network Under the TCP IP Properties Select the Specify an I...

Страница 31: ...le with yellow colored insulation is used for Single Mode applications gray or orange colored insulated cable is for Multimode use If Multimode cable is used in a Single Mode application the test resu...

Страница 32: ...FULL COL LINK ACT each port Optical Signal Status 100M FULL COL LINK ACT each port Alarm Dry Contact Normal Open Power Source Standard 12VDC 500mA Optional 24VDC 48VDC 125VDC or 115 230VAC with an ext...

Страница 33: ...irst inspect such goods at the premises of the Buyer or may give written authorization to Buyer to return the goods to TC Communications Inc transportation charges prepaid for examination by TC Commun...

Страница 34: ...wn Up Up Up 16 Up Up Up Up Down Up Up 17 Down Up Up Up Down Up Up 18 Up Down Up Up Down Up Up 19 Down Down Up Up Down Up Up 20 Up Up Down Up Down Up Up 21 Down Up Down Up Down Up Up 22 Up Down Down Up...

Страница 35: ...Down Down Down Up Down Up 47 Down Down Down Down Up Down Up 48 Up Up Up Up Down Down Up 49 Down Up Up Up Down Down Up 50 Up Down Up Up Down Down Up 51 Down Down Up Up Down Down Up 52 Up Up Down Up Dow...

Страница 36: ...Up Up Down Down Up Down 90 Up Down Up Down Down Up Down 91 Down Down Up Down Down Up Down 92 Up Up Down Down Down Up Down SHR ID Setting 3 1 2 3 4 5 6 7 Dipswitch Value 20 1 21 2 22 4 23 8 24 16 25 3...

Страница 37: ...n Up Down Down Down 117 Down Up Down Up Down Down Down 118 Up Down Down Up Down Down Down 119 Down Down Down Up Down Down Down 120 Up Up Up Down Down Down Down 121 Down Up Up Down Down Down Down 122 U...