Universal Remote Control manual V0.9.1
- 4 -
3. URC DISPLAY AND CONTROL OVERVIEW
Now that the URC is connected to the TBS device, you can turn it on which will
automatically activate the remote panel as well (see chapter 3.1). Before going into
specific details, the image below shows the display and control overview of the URC :
universal remote control
power
enter/menu
select
alarm
1
2
3
4
5
6
7
8
1. TBS device mode indicator. With an inverter connected, symbol
I
indicates inverter on
in normal mode. Symbol
II
indicates inverter on in ASB mode. With a charger
connected, symbol
I
indicates charger on in normal mode. Symbol
II
indicates charger
on in forced float mode.
2. TBS device type indicator. Automatically shows which inverter or charger model is
connected to the URC.
3. Intelligent rotary controller knob. Three way control knob which can be used to select
values, browse through lists and change numeric values.
4. Backlight button. Activates or deactivates the backlight of the LCD
5. LCD parameter field. In normal operating conditions, this field indicates all available
parameters and it’s corresponding values. When this list has more than four rows, you
can use the rotary controller to browse through this list.
6. Power button. This button activates the power options menu, or directly turns off the
TBS device when pressed for 3 seconds.
7. Alarm indicator LED. Flashes red when a TBS device error has occurred. The
corresponding error type will be showed on the display.
8. Power indicator LED. Lits green when the TBS device and remote panel are on.
3.1
URC functionality
As explained above, when the TBS device is switched on using it’s main power switch, the
URC will start up as well showing a green power LED and the following startup screen for
a few seconds :