background image

 

 
 

Universal Remote Control manual V0.9.1 

 

 

 
 

 

- 4 - 

 

3.  URC DISPLAY AND CONTROL OVERVIEW

   

 
 

Now that the URC is connected to the TBS device, you can turn it on which will  

 

automatically activate the remote panel as well (see chapter 3.1). Before going into  

 

specific details, the image below shows the display and control overview of the URC : 

 

universal remote control

power

enter/menu

select

alarm

1

2

3

4

5

6

7

8

 

 
 

1.  TBS device mode indicator. With an inverter connected, symbol 

I

 indicates inverter on  

 

 

in normal mode. Symbol 

II

 indicates inverter on in ASB mode. With a charger  

 

 

connected, symbol 

I

 indicates charger on in normal mode. Symbol 

II

 indicates charger  

 

 

on in forced float mode. 

2.  TBS device type indicator. Automatically shows which inverter or charger model is  
 

connected to the  URC. 

3.  Intelligent rotary controller knob. Three way control knob which can be used to select  
 

values, browse through lists and change numeric values. 

4.  Backlight button. Activates or deactivates the backlight of the LCD 
5.  LCD parameter field. In normal operating conditions, this field indicates all available  
 

parameters and it’s corresponding values. When this list has more than four rows, you  

 

can use the rotary controller to browse through this list. 

6.  Power button. This button activates the power options menu, or directly turns off the  
 

TBS device when pressed for 3 seconds. 

7.  Alarm indicator LED. Flashes red when a TBS device error has occurred. The  
 

corresponding error type will be showed on the display. 

8.  Power indicator LED. Lits green when the TBS device and remote panel are on. 
 

 

 

3.1   

URC functionality

 

 
 

As explained above, when the TBS device is switched on using it’s main power switch, the  

 

URC will start up as well showing a green power LED and the following startup screen for  

 

a few seconds : 

 

Содержание V0.9.1

Страница 1: ...versal Remote Control V0 9 1 TBSLink For Powersine PS1000 1800 inverter series Omnicharge OC20 60 charger series Designed and manufactured in The Netherlands by TBS Electronics BV De Factorij 46 1689...

Страница 2: ...operation from your URC and TBS device it must be installed and used properly Please read this manual very carefully especially the warning and caution statements before installing and using the URC 2...

Страница 3: ...ng screw hole 2 2 Connection to the URC Please follow the installation instructions of your TBS device to connect the URC correctly The URC must be connected inside the connection compartment of a TBS...

Страница 4: ...nt rotary controller knob Three way control knob which can be used to select values browse through lists and change numeric values 4 Backlight button Activates or deactivates the backlight of the LCD...

Страница 5: ...rter or charger power options menu By turning the rotary controller knob you can choose your preferred option This option can be executed by pushing the rotary controller knob or pressing the power bu...

Страница 6: ...ry controller knob 3 clockwise or counter clockwise to adjust to the preferred output current level The output current level is represented as percentage of the maximum rated charge current of your ch...

Страница 7: ...IBILITY TBS Electronics TBS warrants this product to be free from defects in workmanship or materials for 24 months from the date of purchase During this period TBS will repair the defective product f...

Страница 8: ...xidation caused by condensation 5 TECHNICAL DATA TECHNICAL DATA Universal Remote Control TBSLink Databus type TBSLink point to point Connection cable type UTP straight wired patch cable RJ45 8 RJ45 8...

Страница 9: ...product PRODUCT TYPE Wired Remote Control MODEL Universal Remote Control TBSLink Conforms to the requirements of the following Directives of the European Union EMC Directive 2004 108 EC RoHS Directive...

Отзывы: