Notes:
•
The solar charger can be installed in a positive or in a negative grounded system. In a vehicle
for example, always apply a short single ground connection, ideally close to the battery, to
avoid ground loops that could cause system instabilities.
•
Please check the table below for maximum PV and battery current levels plus advised
minimum cable sizes:
Charger
model
PV max. input
current
Min.PV wire
size
Battery max.
charge current
Min. battery
wire size
OCS 100-20
20A
4mm
2
20A
4mm
2
OCS 100-30
30A
6mm
2
30A
6mm
2
OCS 100-50
50A
10mm
2
50A
10mm
2
•
Please check the next table for battery fuse recommendations:
Charger model
Min. fuse rating
Max. fuse rating
OCS 100-20
25A
30A
OCS 100-30
40A
50A
OCS 100-50
70A
85A
•
When the optional battery temperature sensor is connected to the solar charger to enable
temperature compensated charging, please make sure that this sensor is located as close as
possible to the battery. When no temperature sensor is connected to the solar charger,
charge voltages will not be compensated against varying temperature.
•
The Expansion Port is intended for future use. Do not connect to any device.