13
Position 3
AGM
(also for
Optima
SpiralCell)
Absorption voltage = 14.70V or 29.40V
Float voltage = 13.65V or 27.30V
Equalize voltage = 15.50V or 31.00V
Max. bulk time = 8hrs
Max. absorption time = 4hrs
Position 4
Lead
Calcium
Absorption voltage = 14.80V or 29.60V
Float voltage = 13.50V or 27.00V
Equalize voltage = 15.80V or 31.60V
Max. bulk time = 16hrs
Max. absorption time = 8hrs
Position 5
LiFePO4
Absorption voltage = 14.40V or 28.80V
Float voltage = 13.80V or 27.60V
Equalize voltage = equalize not available
Max. bulk time = 12hrs
Max. absorption time = 12hrs
Position 6
Empty
Reserved for future use.
If selected anyway, the charger will return a battery error.
Position 7
Empty
Reserved for future use.
If selected anyway, the charger will return a battery error.
Position 8
Empty
Reserved for future use.
If selected anyway, the charger will return a battery error.
Position 9
Empty
Reserved for future use.
If selected anyway, the charger will return a battery error.
This manual will only describe the rotary selector settings. Configuration by TBS Dashboard
will be explained in the TBS Dashboard manual that comes with the TBSLink to USB
Communication Kit.