solution of water and baking soda.
Routing checks
Periodically, check all wiring connections, Dc and AC, to be sure
they have not loosened or deteriorated. Also check all cable
clamps to ensure they are tightly fastened.
6.2
TROUBLESHOOTING
Display
Condition
“Power” indicator light is OFF
Battery charger disconnected
Power supply failure
Incorrect power supply connection
Mains voltage too low
Mains fuse blown
“Power” indicator light is flashing
Battery connection not good
Wrong voltage battery connected (24V to
12V battery charger)
“Charged” indicator light is flashing,
battery charger has no output
The equalization switch (switch 3) is set to
ON before the battery charger is power on.
Please power off the battery charger. Reset
the equalization switch to Off, then power
on the battery charger.
“Reverse polarity” indicator light ON
Polarity reversion on output
“Reverse polarity” indicator light flashing
Charger over temp. charger will reduce the
output power
“Charging” and “Charged” indicator light
flashing
Battery over temp, charger shut off