background image

7

3.3  STATUS INDICATORS
 

Table 3-3: LED codes

No.

Print

Colour

Status

Description

1

Power

Green

ON

Working normal

OFF

No working or Low Power Mode

3

Alternator

Green

ON

Motor battery voltage in the range

Flashing

Motor battery voltage high

OFF

Motor battery voltage low

4

Charge

Green

ON

Charging battery at bulk or absorption stage

Flashing

Charging battery at float stage

OFF

No charging to auxiliary battery

5

Fault

Red

ON

1. PMDC-30 over temperature
2. Motor battery voltage high
3. Output to auxiliary battery short circuit

Flashing

1. Auxiliary battery over temperature or under temperature

OFF

No fault

 

4.

 

INSTALLATION

4.1  MATERIAL CHECKING

 

Before installation, check that the product is in good physical condition.

  

 

4.3   PROPER INSTALLATION LOCATION

• 

PMDC-30 is designed with IP20 and for internal installation ONLY.

• 

The temperature at the casing and heat sink of PMDC-30 can be as high as 60°C 
during operation. 

• 

Ensure PMDC-30 is installed away from flammables and explosives.

• 

Please have the installation away from inflammable and explosive goods.

• 

Ensure PMDC-30 is installed out of reach of children.

• 

Ensure mounting surface is flat and rigid.

Please check the item with the list attached in the box.

Never install PMDC-30 in a sealed enclosure with battery.

Содержание Projecta PMDC-30

Страница 1: ...DC DC CHARGER Intelli Jay Integration P No PMDC 30 C4975F Need technical help Contact Projecta on 1800 294 294 INTELLI...

Страница 2: ...Intelli Jay transformer polarities are correct Use the shortest possible cable lengths to connect the Input and Output circuits to the unit Ensure there s sufficient ventilation around the heatsink o...

Страница 3: ...is up to 96 PMDC 30 also supports communication of RS485 Alternator type Alternator input voltage Working state Conventional alternator 12 8V ON 12 0V OFF 2 3 MULTI STAGE CHARGING ALGORITHM PMDC 30 is...

Страница 4: ...emperature of battery and automatically makes adjustments at real time to properly charge your batteries at the default compensation rate of 3mv C cell If the BTS is not present connected the PMDC 30...

Страница 5: ...5 3 STRUCTURE AND DIMENSION 3 1 EXTERIOR AND DIMENSION Figure 3 1 PMDC 30 front view Figure 3 2 PMDC 30 dimensions...

Страница 6: ...ive and negative of auxiliary battery Connect to IntelliJay Black Label Vehicle Batt 3 COM For communication of RS485 Not Connected 4 1 Dip switch for output current setting Details of setting can be...

Страница 7: ...lashing 1 Auxiliary battery over temperature or under temperature OFF No fault 4 INSTALLATION 4 1 MATERIAL CHECKING Before installation check that the product is in good physical condition 4 3 PROPER...

Страница 8: ...the PMDC 30 is installed See recommended spacing dimensions below Figure 4 1 The required dimensions for ventilation 4 5 MOUNTING HOLES Find an appropriate mounting surface flat and rigid Drill mounti...

Страница 9: ...ch for battery type setting Battery type Absorption charging voltage Float charging voltage Pin 3 Pin 4 OFF OFF AGM 14 6V 13 5V OFF ON GEL 14 2V 13 8V ON OFF LFP 14 4V 13 5V ON ON WET Default setting...

Страница 10: ...A Maximum charging efficiency 96 Temperature compensation Default Setting 3mV C cell Voltage compensation Yes Charge algorithm Premium II multi stage Protection Battery charger over temperature Over l...

Страница 11: ...11 NOTES...

Страница 12: ...hase or to any other place which may be nominated by either BWI or the retailer from where the product was bought in order that a warranty assessment may be performed The consumer must also deliver th...

Отзывы: