2.2 BLOCK DIAGRAM
Figure 2-1: Block Diagram of PMDC-30
DC/DC
Converter
MCU
Motor
battery
Intelli-Jay Transformer
D+
LED
COM
Voltage detect
Temperature detect
Voltage detect
Alternator
DIP
Switch
30A
30A
Battery Voltage
Charging Current
Soft Start
Bulk
Absorption
Float
Recycle
Icc
11.5V
10 days
1h
5
mins
½ Icc
The charging efficiency of the PMDC-30 is up to 96%.
PMDC-30 also supports communication of RS485.
Alternator type
Alternator input voltage
Working state
Conventional alternator
12.8V
ON
12.0V
OFF
2.3 MULTI STAGE CHARGING ALGORITHM
PMDC-30 is able to charge House battery through the Intelli-Jay transformer quickly
and fully. Microprocessor controlled charging algorithm with variable absorption
charging timer to guarantee the optimal charging for batteries of different
discharged states.
Figure 2-2: Charging Algorithm
PMDC-30 will treat it as conventional engine rather than
Euro 6 engine.