Specification 

Table 9 Specification of LMP-PWM

 

Model 

 

 

LMP1218-PWM 

Electrical Specifications 

AC Power 

Nominal input voltage (V) 

230±10%VAC 50/60Hz 

Power factor 

0.98 

Input current at full load 

1.3A 

Battery 

Starter battery 

12Vdc 

Starter battery voltage range 

12.8-14.8Vdc 

Service battery 

12Vdc 

Service battery voltage range 

10.8-16.2Vdc 

Solar Panel 

Charger type 

PWM 

Open circuit voltage 

25Vdc 

Max supply current 

15A 

Charging Relay 

Relay specification 

12Vdc 30A continuous,   

peak current 50A 

Connect voltage 

13.4V 

Connect delay time 

10sec 

Disconnect voltage 

12.8V 

Disconnect delay time 

60sec 

High voltage limit 

14.8Vdc 

Charger mode 

Charge Algorithms 

TBB premium II - 5steps 

Battery type 

AGM/GEL/LFP/WET 

Bulk current 

18A(Max) 

Absorption voltage 

(14.4/14.1/14.4/14.7)±0.2Vdc 

Float voltage 

(13.5/13.5/13.5/13.7)±0.2Vdc 

Power supply 
mode 

Nominal output voltage 

12.8±0.2Vdc 

Rated output current   

18A(Continuous) 

Efficiency(Max) 

88% 

Working temperature 

-20

~+40

 

Others 

Battery 
Disconnect(LVD

Disconnect voltage 

AGM/GEL/WET 

10.8Vdc(default) 

LFP 

11.2 Vdc(default) 

Delay off time 

60sec 

Reconnect voltage 

AGM/GEL/WET 

11.8Vdc(default) 

LFP 

12.2 Vdc(default) 

Protection   

Short circuit on output 

Fuse blown 

Reverse Polarity 

Fuse blown 

Overload protection 

Derate the output until overload is 

removed 

Battery charger over 
temperature 

Shut down LMP-PWM 

Содержание idSWITCH LMP1218-PWM

Страница 1: ...LMP1218 PWM Master Power Unit User Manual IDM Technologie LMP1218 PWM Master Power Unit Version A1 0 Date Apr 2020...

Страница 2: ...Power Unit User Manual IDM Technologie WARNING FIRE HAZARD SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON COMBUS TABLE SURFACE ONLY CAUTION THE DC AND AC BREAKER MUST HAVE BEEN TURNED OFF BEFORE SERVI...

Страница 3: ...u uc ct ti io on n Thanks for choosing our products and this manual were suitable for LMP1218 PWM Master Power Unit This chapter contains important safety and operation instructions Read and keep this...

Страница 4: ...r of Auxiliary Battery 4 3 3 Power Supply Mode 5 3 4 PWM Solar charger controller 5 3 5 Voltage Charging Relay VCR 5 3 6 Battery Low Voltage Protection BLVP 5 3 7 Manual Battery Switch 5 3 8 DC Distri...

Страница 5: ...218 PWM Master Power Unit would be overheating 1 2 2 To avoid fire and electric shock make sure all cables selected with right gauge and being connected well Smaller diameter and broken cable are not...

Страница 6: ...compensated Charging Voltage compensated Charging 16 Fused DC outputs including water pump and lighting central control Battery charging relay 12V 30A Battery Low Voltage Protection Built in Battery S...

Страница 7: ...splay Table 1 LED indication NO LED Color Status Description 1 CHG Green ON Battery charged Flashing flash once every second Battery charging OFF Battery discharge 2 Dischg Orange ON Battery dischargi...

Страница 8: ...s Solar panel AC mains Solar panel AC mains Alternator Solar panel Solar panel 3 2 Battery Charger of Auxiliary Battery The charger automatically starts when the appropriate qualified power is connect...

Страница 9: ...or battery s voltage drops under 12 8VDC LiFePO4 LITHIUM BATTERY When the motor battery reaches 14 0VDC with threshold time delay the VCR will be engaged to allow power from alternator to supply the s...

Страница 10: ...wer Unit User Manual IDM Technologie 6 on board It protects the auxiliary battery from being drained by electronics on board completely isolating the battery 3 8 DC Distribution Figure 2 DC distributi...

Страница 11: ...AC input port 2 PV Connect to PV Panel 3 Fridge Connect to fridge 4 Lifting Bed Connect to lifting bed 5 Motor BAT Connect to Motor BAT 6 AUX BAT Connect to AUX BAT 7 Loads 1 1 POS Awning lamp 1 2 GND...

Страница 12: ...itchen 2 15 M1 Footstep 2 16 POS Plug USB Kitchen Bedroom 2 17 GND Plug USB Kitchen Bedroom 2 18 Footstep 9 Loads 3 1 POS Permanent Autoradio 3 2 GND 3 3 POS SAT antenna 3 4 POS Combi TRUMA ALDE contr...

Страница 13: ...Connect to RS485 bus 14 CI Bus port Connect to CI bus 15 Communication port 4 1 Wake up 4 2 GND 4 3 GND 4 4 12V 4 5 CAN H 4 6 CAN L 16 DIP Switch 1 VCR Set the battery type VCR and Mode 2 Mode 3 Bat t...

Страница 14: ...8 PWM Master Power Unit User Manual IDM Technologie 10 Figure 5 Dimensions of LMP1218 PWM 4 3 Fuse specification Here is a list for the fuses installed on LMP1218 PWM Please also take reference of Fig...

Страница 15: ...ng 1 10A F7 Lighting 2 10A F9 USB Socket Bedroom 10A F10 USB Socket Kitchen 10A F11 12V Socket Kitchen 15A F12 Permanent SAT Antenna 10A F13 Permanent Autoradio 5A F14 Permanent Heating System 10A F15...

Страница 16: ...mode and Working mode selection a VCR mode There are two VCR modes for optional Integrated VCR when this mode is selected the integrated VCR is activated i e 18A Ex DC DC When this mode is selected th...

Страница 17: ...age of 12 8 Vdc to power the connected DC loads 5 1 1 2 Dip switch for battery setting Table 7 Dip switch for battery type setting Battery type Position 3 Position 4 Battery type off off AGM off on GE...

Страница 18: ...rm the Battery Switch is switching on when you want to charge the battery with the AC grid Check the nominal battery voltage is 12Vdc When replacing the existing battery with a new one please have the...

Страница 19: ...PWM Unit Table 8 Error LED indicator of LMP PWM NO LED Color Status Description 1 CHG DISCHG Green Orange Flash once per cycle Service battery voltage low 2 Flash twice per cycle Service battery volta...

Страница 20: ...e 10sec Disconnect voltage 12 8V Disconnect delay time 60sec High voltage limit 14 8Vdc Charger mode Charge Algorithms TBB premium II 5steps Battery type AGM GEL LFP WET Bulk current 18A Max Absorptio...

Страница 21: ...ery over voltage limits Battery charger disconnect loads disconnect Physical Specifications Dimensions L W H 235 185 98 5 mm Weight kg 2kgs Enclosure Plastic case Cooling Free cooling Protection categ...