BMS circuit
high
temperature
protection
Please check whether the ambient temperature of
the battery installation location is too high.
Please check whether the battery wiring is tight and
reliable.
Please check whether the wire diameter of the
battery wiring cable meets the requirements of the
manual.
Please check whether the discharge current and
discharge time of the lithium battery exceed the
specified
requirements
(see
the
technical
parameter table for details)
If the above is normal, please contact your dealer.
13
BMS circuit
low
temperature
protection
Please check whether the ambient temperature of
the battery installation location is lower than -40°C.
If it is, the battery is not suitable for operation in
such a low ambient temperature, and the ambient
temperature for battery installation is preferably
above -30°C.
If the above is normal, please contact your dealer.
14
External
input
overvoltage
protection
Check whether the charging voltage of the charger
matches the lithium battery. The charging voltage
should be 14.0~14.2V.
Check whether the charger is abnormal.
If all the above are normal, please contact your
dealer after turning off the charger.
15
BMS
internal
failure
Please contact your dealer.
Continuous
flashing
Parallel
communicat
ion failure
Please check whether the parallel communication
cable is correctly connected according to the
manual (see chapter 3.6.1 for details).
Please check whether the communication network
cable is loose or damaged. You can try to replug the
network cable or replace it with a new
communication network cable.
If all the above are normal, please contact your
dealer.