background image

 

                                                                                               

               

Energy Hub User Manual

 

                                                           

  

13 

5)  Charge Only

 

function 

Switch on MEH to 

O

, when the system is turned off, the lithium battery can be charged by the 

Alternator /Solar /

 

Grid. The system only allows charging and prohibits discharging.

 

The system 

switches off the inverter and DC load via Dry Contact2 and Dry Contact3. Features as below: 

 

 

When the Alternator input voltage meets the operating conditions of the internal booster 
charger, the internal booster charger turns on the charging output, charging activates the 
wake-up system and charges the Hub. When charging to SOC 100%, the system will stop 
charging and turn off the lithium battery, and the system will all automatically power down. 

 

When the Solar input voltage meets the Solar Mate operating conditions, the Solar Mate is 

powered up to detect the status of the battery side

 

a)  When the system is switched off and other charging sources are not working, the Solar 

Mate has to wait 5min before the output starts, the charging activation wakes up the system 

and charges the Hub; if the Solar is underpowered, the first time causes the Solar Mate 

output to be pulled down, the second and subsequent times the Solar Mate has to wait 

another 20min before the output can be switched on again to start the system. 

b)  When other charging sources are charging the Hub, the SP starts outputting to charge the 

Hub after 30s of power-up self-test. 

 

When the Grid meets the CM operating conditions, the CM will turn on the charge output after 
30s of power-up self-test, charge activation wakes up the system and charges the Hub.   

6)  Use the Hub in a low temperature environment 

 

When the cell temperature is 

2

, the user cannot directly charge the Hub. In the low 

temperature environment, when the internal charger is turned on, the Hub will automatically 

turn on the heating function. After the built-in lithium battery is heated to 5

, the Hub can be 

charged normally. 

 

When the ambient temperature is lower than -20°C, the Hub cannot be discharged and a low 
temperature fault alarm will be reported. The user can via the internal charger to heat the 
built-in battery before starting to discharge it.   

 

At low temperatures, the battery discharge capacity decays by 10% to 30%. The lower the am
bient temperature, the more the discharging capacity decays. 

 

 

Содержание Energy Hub EH128L

Страница 1: ...Preface...

Страница 2: ...ge value of the product Please make sure that the cable between the product and the inverter is as short as possible Please ensure that the polarity connections of the DC load and inverter are correct...

Страница 3: ...ual Content 1 Safety Precautions 1 2 Product Introduction 2 3 External Interface Description 3 4 Product Installation 5 5 Operation 10 6 Storage and Transportation 14 7 Compatible Products 15 8 FAQ 18...

Страница 4: ...parallel Do not short circuit the lithium battery output interface Especially keep these rules Do not expose the Energy Hub to water or fire for risk of electrocution or explosion Do not push any obje...

Страница 5: ...ring 5 times more life expectancy compared with lead acid battery To assure the best performance sophisticated BMS has been designed integrating many unique features High discharge current Built in pr...

Страница 6: ...input interface 5 USB 2 0A 2 0A USB port 6 12V DC SOCKET 12V DC socket 7 INVERTER Inverter DC interface 8 DC LOAD DC load interface 9 0V Negative pole of system 10 Dry Contact 1 NO Relay output norma...

Страница 7: ...ff Off On 0 SOC 25 Blink 2 Off Off Off On Battery discharging 75 SOC 100 On On On On Blink 3 50 SOC 75 On On On Off Blink 3 25 SOC 50 On On Off Off Blink 3 0 SOC 25 On Off Off Off Blink 3 SOC 0 Off Of...

Страница 8: ...olarity Wire diameter Length Color Standard Alternator interface Blue See the table below for details Inverter Interface Red See the table below for details DC load interface Gray See the table below...

Страница 9: ...3m Red Negative pole 6 10mm2 3m Black Inverter power Max DC current Recommended Cable Size Polarity Wire diameter Length Color 700W 70A Positive pole 16 25mm2 3m Red Negative pole 16 25mm2 3m Black 1...

Страница 10: ...load interface ANENANNENG CONNECTOR Gray Step 2 Positioning and Perforation Please select a plane and drill holes according to the installation positioning requirements in figure below Attention The p...

Страница 11: ...d of the prepared wire to the C12 load module and the other end to the DC LOAD interface of Energy Hub with an Anderson connector And please connect your DC load to the C12 load module If you have pur...

Страница 12: ...he prepared network cable to the 4G data stick or A7 touch screen and the other end to the Data Logger interface of the Energy Hub 6 Please connect one end of the prepared network cable to the MEH and...

Страница 13: ...control signal or ignition signal otherwise the charger works in traditional alternator mode D signal control logic Generator Type D signal status Starting battery voltage conditions Working Status S...

Страница 14: ...load or the negative terminal of the inverter 2 Output dry contact NO interface is connected to Engine Start controller Dry contact 2 When the dry contact 2 connect to the remote of inverter it will c...

Страница 15: ...et the output of C12 will be turned on via Dry Contact3 SOC 0 0 45 can be set SOC of the C12 output is turned on SOC of the C12 output is turned off 5 the output of C12 will be turned off via Dry Cont...

Страница 16: ...r is underpowered the first time causes the Solar Mate output to be pulled down the second and subsequent times the Solar Mate has to wait another 20min before the output can be switched on again to s...

Страница 17: ...r month Be sure to store it in the power OFF state Note Before storing the lithium battery please charge the battery to 100 SOC Please disconnect all loads and chargers connected to the Energy Hub Ple...

Страница 18: ...er output data Voltage Current Power Solar data PV voltage Output current Output power Switch on off Energy Hub and the Inverter With Bluetooth connectivity to support mobile APP 2 4G data stick Avail...

Страница 19: ...rowave and power tools Kinergier Mobile bi directional inverter Kinergier Mobile bi directional inverter is the new generation of bi directional inverter which is widely used in vehicle and marine sys...

Страница 20: ...output by as much as 30 compared with PWM design Maximum MPPT efficiency up to 99 9 Maximum efficiency up to 98 2 Excellent performance at sunrise and low solar insulation levels High reliability with...

Страница 21: ...voltage protection The battery capacity is already low please recharge the Energy Hub immediately 6 General high voltage protection Check that the charging voltage of the external charger matches that...

Страница 22: ...nstallation location is not too high Please check that the discharge current and discharge time of the Energy Hub do not exceed the specified requirements see 9 Specification If the above is correct p...

Страница 23: ...nal type Anderson SA120 Red DC output 2 To DC LOAD Output voltage range 11 6 14 2VDC Continuous current Max120ADC Max 55ADC Terminal type Anderson SA120 Gray DC output 3 To 12V DC SOCKET continuous cu...

Страница 24: ...Energy Hub User Manual 21...

Отзывы: