Tayosan SRE 3001 Скачать руководство пользователя страница 3

33 

SUMMARY OF THE OPERATION 

 

 

IGNITION – SHUTTING OFF – FASTEN IGNITION

 

 
To ignite your heater, press the switch ON, the operation lamp lamp goes red. During ignition (+/- 2 minutes),  a 
calculation will be done from 5 to 1 then the apparatus ignites.  
To shut off your heater, press the switch OFF, the operation lamp goes out, the blower fan will remain on for 
approximately 3 minutes to cool down your heater. 

 
ADJUSTING THE TEMPERATURE

 

 
The preset temperature will be set at 20° C, to raise the temperature, press on + and to lower the temperature, 
press on -.  You can set the temperature between 2°C and 30°C. 
 

SETTING THE TEMPERATURE –  AUTO OPERATION 

 
To use the regulation of you heater, press AUTO switch, the AUTO lamp will come on. You just have to select 
the temperature with  and –.  The heater will not shut off but will adjust his power in function with the 
room temperature. 
 

SETTING THE TEMPERATURE – ECO/SAVE OPERATION 

 
To use the thermostat of your heater, press SAVE switch, the SAVE lamp will come on.  You just have to select 
the shutting off temperature with  and -.  The heater will shut off 3 to 5°C above the setting temperature 
and will re-ignite when the setting temperature is reached. 
 

SETTING THE TEMPERATURE – MIN OPERATION 

 
To set the maximum power of your heater at 800 Watt (for SRE3001/FR32) and 1100 Watt (for SRE4600/
FR46), , press MIN switch, the MIN lamp will come on. You just have to select the temperature with  
and –.  The heater will work at his minimal power whatever the selected temperature or that of the room.  
 

SET THE TIME   

 
To set the time, press MODE switch, the clock set lamp is lit, the digitally displayed time is flashing at 00:00 at 
time of purchase.  Press on sw and – to set the time. The time setting will be completed after you have 
wait for few seconds. 
 

TIMER OPERATION  

 
You have first to set the time, then press switch ON (it is not necessary if the heater is working). Press switch 
TIMER, the heater will turn off or is not working. The display shows automatically “6:00”, you can set the start 
time with sw and – as for the setting off time. Once the start time is selected, wait for a few seconds  
and the setting will be completed.  The timer operation works only if the TIMER switch is green. 
 

PREVENTING TAMPERING – CHILD SAFETY LOCK 

 
To set the child safety lock, press CHILD SAFETY LOCK switch for more than 3 seconds, the child safety lock 
lamp will come on.  To cancel, press CHILD SAFETY LOCK switch for more than 3 seconds again and the 
operation switch will turn off. 
 

  

Содержание SRE 3001

Страница 1: ...ion Instructions Special precaution for safety 34 List of parts 37 Preparation procedures 41 Unpacking 41 Pre ignition preparations and checkpoints 41 Fuel to be used 42 Fuel filling 44 Elevation adju...

Страница 2: ...is would risk causing a failure of the system which is there for your safety p 51 This heater may not be used in rooms which are hermetically sealed such as caravans boats passenger compartments of ve...

Страница 3: ...n the setting temperature is reached SETTING THE TEMPERATURE MIN OPERATION To set the maximum power of your heater at 800 Watt for SRE3001 FR32 and 1100 Watt for SRE4600 FR46 press MIN switch the MIN...

Страница 4: ...every hour Lack of oxygen causes imperfect combustion which may cause highly toxic carbon monoxide emissions in the room It is very dangerous DO NOT use the heater in the basement with no ventilation...

Страница 5: ...uction may cause fuel leak and fire CAUTION off AVOID locations close to drapes of flammable ma terial DO NOT put laundries sofas too close to the blower unit Flammable material or objects may cause f...

Страница 6: ...le or a boat in direct sunlight or at the place where the temperature tends to rise quickly in places where gas or chemicals e g freon gas chloride compounds are used such as beauty salons barber shop...

Страница 7: ...Hz household use ONLY Fuel tank cover Control panel Indicators Warm air blower Louver Base plate Drain slot Room thermo sensor Power cord Power plug Air intake filter Air intake for combustion Warm ai...

Страница 8: ...ad time back 47 48 49 POWER SELECTOR KEY Use MIN AUTO SAVE for using pur pose respectively 47 ON KEY OPERATION LAMP Use when starting the heater operation The lamp is lit red under operation pre heati...

Страница 9: ...ELECTOR KEY Temperature current time timer programmed time can be selected to in dicate ON KEY OPERATION LAMP Use when starting the heater operation The lamp is lit red under operation pre heating The...

Страница 10: ...16 Time lamp is light off Indicates current time Timer set time lamp is lit Indicates the pre set time for the timer 56 47 48 49 HEAT POWER LAMP Indicates the heat power se lected Example shows AUTO...

Страница 11: ...ace with high temperature liquid combustible for mobile heater kept in a white polypropylene container or in an uncapped container for long time Always use the proper liquid combustible container Impu...

Страница 12: ...heat rain dust and from other heat sources Liquid combustible for mobile heater which has been stored too long loses its purity and thus its efficiency ADDING LIQUID COMBUSTIBLE FOR MOBILE HEATER Whe...

Страница 13: ...r of bad quality has a yellow colour and a acid smell Use up fuel within the season WHAT HAPPENED IF YOU USE BAD LIQUID COMBUSTIBLE FOR MOBILE HEATER Tar form in evaporator and ignition and extinguish...

Страница 14: ...he safety Avoid hitting the filler cap to be distorted Distorted filler cap may cause liquid combustible leaks Be careful not to drop the tank 4 Replace the tank Carefully replace the filled tank into...

Страница 15: ...ecoveries Ventilate the room to get fresh air Remove dust on the intake filter Relocate the heater to proper places Unstable flames Cause Stuck fuel flow caused by dirties along pumping system Recover...

Страница 16: ...during operation Extinguishment will be completed when the odor free lamp goes off and the fan continues to run for about 3 minutes to cool down the Unit TURNING OFF CAUTION NEVER try to extinguish fl...

Страница 17: ...n you can select three modes SAVE AUTO and MINI In SAVE mode The heater automatically stop the operation when the room tempera ture goes up 2 centigrade higher than the setting temperature NOTES Prese...

Страница 18: ...00 then the current time Time figure can be changed from the second press 3 Adjust to the correct time Minutes can be adjusted by one minute at each press Keep the key pressed for a few seconds and t...

Страница 19: ...h pressing of time key Press the key for a few seconds and the figure will continue to change After the minutes reaches 10 figure changes by every ten minutes Press the key one at a time for minute ad...

Страница 20: ...of power failure caused by earthquakes digital indicator will show E4 and red operation lamp will flash In either case timer lamp is not on Press OFF key then follow the procedure for current time ad...

Страница 21: ...reserve a minimum clearance of 1 meter from other objects SOME CAUTIONS DO NOT USE YOUR HEATER IN ROOMS SITUATED UNDER THE FLOOR LEVEL AIR SENSOR DETECTOR This heater has been designed with an Air sen...

Страница 22: ...iately and consult local distribu tor or your nearest customer service agent At Least Once A Week Use soft cloth to clean the Unit body Use a vacuum cleaner to remove dust on the warm air blower louve...

Страница 23: ...nit Remove fuel tank out of the Unit 2 Remove fuel strainer from fuel receiver Be careful not to drop any dust or water onto the receiver 3 Rinse the fuel strainer with clean pure liquid combustible f...

Страница 24: ...water oil into used newspapers and dispose them If imperfect combustion remains despite of the above procedure contact your local distributor or the nearest customer service agent It is recommendable...

Страница 25: ...equires 1 to 2 minutes of preheating During Combustion Burner head turns red It turns red at minimum heating power It is normal unless there is false ignition or flames accidentally go out Flames glow...

Страница 26: ...e Unit Combustion Control System has been triggered Earthquakes seismic scale 5 or larger strong impact on the Unit Auto shut off Device has been triggered Overheat inside the Unit Anti overheat devic...

Страница 27: ...iver Check that the Unit is placed on flat and even ground surface and that its surrounding is safe Wait till the Unit cools down and clean the warm air intake Remove blocking object if any from the w...

Страница 28: ...user s liability STORAGE 1 Unplug the Unit 2 Empty fuel tank and fuel receiver Remaining liquid may cause rust or metal erosion 3 Clean the Unit body air intake filter and warm air intake with dry clo...

Страница 29: ...ut MAX 3000 4600 Watt Average 1890 2840 MIN 775 1020 Fuel tank capacity L 4 0 L 7 1 L Continuous Combustion Capacity MAX 49 4 h 65 9 h MIN 12 5 h 14 5 h Suitable room size in m MAX 120 MIN 48 184 MIN...