Tayosan SRE 3001 Скачать руководство пользователя страница 12

42 

Fuel to be used

 

More  than  95  %  of  problems  are  due  to  using  a  wrong  type  of liquid  combustible  for  mobile 
heater. Those problems are not covered by our guarantee.  
 
Only  top-quality liquid  combustible  for  mobile  heater,  with  the  aromatics  removed  and  totally 
free of impurities (max 1 % of aromatics and a flash-point above 61°). 
Never  use  contaminated  liquid  combustible  for  mobile  heater,  or  which  has  been  chemically 
treated, contains water or petrol. 
 
Your container should be clean and empty when you fill it at a station-service. No impurities or 
other  liquids  (water,  diesel,  gasoline,  etc.)  should  remain.  You  ought  to  keep  a  container 
specifically for filling your heater. 
 
 

STORAGE OF THE LIQUID COMBUSTIBLE FOR MOBILE HEATER 

 
Store your liquid combustible for mobile heater away from the sun, heat, rain, dust and from 
other heat sources. 
Liquid combustible for mobile heater  which has been stored too long loses its purity and thus 
its efficiency. 

ADDING LIQUID COMBUSTIBLE FOR MOBILE HEATER 

 
When your tank is out of the unit, the heater can still be used for a certain period. 
You have to fill your heater: 

When your heater has stopped. 

Or in a room other than the one where the heater is installed. 

You always have to check that the tank cap is well fastened. Please check away from any 
other heat source or fire. 

How  to  distinguish  gasoline  and 
liquid  combustible  for  mobile 
heater: 

 

Take  a  sample  on  your  finger  tip 
and breath out upon it. 
Gasoline  will  evaporate  and  in-
stantly your finger tip will dry out. 
Kerosene will remain your on finger 
tip for a while. 
(Be  sure  to  do  this  where  no  heat 
or fire is around.) 

Liquid 

combustible 

for 

mobile heater 

Be  sure  to  use  only  pure  liquid 
combustible for mobile heater  
Never  use  gasoline,  deteriorated 
combustible, impurified combustible 
 
 

Содержание SRE 3001

Страница 1: ...ion Instructions Special precaution for safety 34 List of parts 37 Preparation procedures 41 Unpacking 41 Pre ignition preparations and checkpoints 41 Fuel to be used 42 Fuel filling 44 Elevation adju...

Страница 2: ...is would risk causing a failure of the system which is there for your safety p 51 This heater may not be used in rooms which are hermetically sealed such as caravans boats passenger compartments of ve...

Страница 3: ...n the setting temperature is reached SETTING THE TEMPERATURE MIN OPERATION To set the maximum power of your heater at 800 Watt for SRE3001 FR32 and 1100 Watt for SRE4600 FR46 press MIN switch the MIN...

Страница 4: ...every hour Lack of oxygen causes imperfect combustion which may cause highly toxic carbon monoxide emissions in the room It is very dangerous DO NOT use the heater in the basement with no ventilation...

Страница 5: ...uction may cause fuel leak and fire CAUTION off AVOID locations close to drapes of flammable ma terial DO NOT put laundries sofas too close to the blower unit Flammable material or objects may cause f...

Страница 6: ...le or a boat in direct sunlight or at the place where the temperature tends to rise quickly in places where gas or chemicals e g freon gas chloride compounds are used such as beauty salons barber shop...

Страница 7: ...Hz household use ONLY Fuel tank cover Control panel Indicators Warm air blower Louver Base plate Drain slot Room thermo sensor Power cord Power plug Air intake filter Air intake for combustion Warm ai...

Страница 8: ...ad time back 47 48 49 POWER SELECTOR KEY Use MIN AUTO SAVE for using pur pose respectively 47 ON KEY OPERATION LAMP Use when starting the heater operation The lamp is lit red under operation pre heati...

Страница 9: ...ELECTOR KEY Temperature current time timer programmed time can be selected to in dicate ON KEY OPERATION LAMP Use when starting the heater operation The lamp is lit red under operation pre heating The...

Страница 10: ...16 Time lamp is light off Indicates current time Timer set time lamp is lit Indicates the pre set time for the timer 56 47 48 49 HEAT POWER LAMP Indicates the heat power se lected Example shows AUTO...

Страница 11: ...ace with high temperature liquid combustible for mobile heater kept in a white polypropylene container or in an uncapped container for long time Always use the proper liquid combustible container Impu...

Страница 12: ...heat rain dust and from other heat sources Liquid combustible for mobile heater which has been stored too long loses its purity and thus its efficiency ADDING LIQUID COMBUSTIBLE FOR MOBILE HEATER Whe...

Страница 13: ...r of bad quality has a yellow colour and a acid smell Use up fuel within the season WHAT HAPPENED IF YOU USE BAD LIQUID COMBUSTIBLE FOR MOBILE HEATER Tar form in evaporator and ignition and extinguish...

Страница 14: ...he safety Avoid hitting the filler cap to be distorted Distorted filler cap may cause liquid combustible leaks Be careful not to drop the tank 4 Replace the tank Carefully replace the filled tank into...

Страница 15: ...ecoveries Ventilate the room to get fresh air Remove dust on the intake filter Relocate the heater to proper places Unstable flames Cause Stuck fuel flow caused by dirties along pumping system Recover...

Страница 16: ...during operation Extinguishment will be completed when the odor free lamp goes off and the fan continues to run for about 3 minutes to cool down the Unit TURNING OFF CAUTION NEVER try to extinguish fl...

Страница 17: ...n you can select three modes SAVE AUTO and MINI In SAVE mode The heater automatically stop the operation when the room tempera ture goes up 2 centigrade higher than the setting temperature NOTES Prese...

Страница 18: ...00 then the current time Time figure can be changed from the second press 3 Adjust to the correct time Minutes can be adjusted by one minute at each press Keep the key pressed for a few seconds and t...

Страница 19: ...h pressing of time key Press the key for a few seconds and the figure will continue to change After the minutes reaches 10 figure changes by every ten minutes Press the key one at a time for minute ad...

Страница 20: ...of power failure caused by earthquakes digital indicator will show E4 and red operation lamp will flash In either case timer lamp is not on Press OFF key then follow the procedure for current time ad...

Страница 21: ...reserve a minimum clearance of 1 meter from other objects SOME CAUTIONS DO NOT USE YOUR HEATER IN ROOMS SITUATED UNDER THE FLOOR LEVEL AIR SENSOR DETECTOR This heater has been designed with an Air sen...

Страница 22: ...iately and consult local distribu tor or your nearest customer service agent At Least Once A Week Use soft cloth to clean the Unit body Use a vacuum cleaner to remove dust on the warm air blower louve...

Страница 23: ...nit Remove fuel tank out of the Unit 2 Remove fuel strainer from fuel receiver Be careful not to drop any dust or water onto the receiver 3 Rinse the fuel strainer with clean pure liquid combustible f...

Страница 24: ...water oil into used newspapers and dispose them If imperfect combustion remains despite of the above procedure contact your local distributor or the nearest customer service agent It is recommendable...

Страница 25: ...equires 1 to 2 minutes of preheating During Combustion Burner head turns red It turns red at minimum heating power It is normal unless there is false ignition or flames accidentally go out Flames glow...

Страница 26: ...e Unit Combustion Control System has been triggered Earthquakes seismic scale 5 or larger strong impact on the Unit Auto shut off Device has been triggered Overheat inside the Unit Anti overheat devic...

Страница 27: ...iver Check that the Unit is placed on flat and even ground surface and that its surrounding is safe Wait till the Unit cools down and clean the warm air intake Remove blocking object if any from the w...

Страница 28: ...user s liability STORAGE 1 Unplug the Unit 2 Empty fuel tank and fuel receiver Remaining liquid may cause rust or metal erosion 3 Clean the Unit body air intake filter and warm air intake with dry clo...

Страница 29: ...ut MAX 3000 4600 Watt Average 1890 2840 MIN 775 1020 Fuel tank capacity L 4 0 L 7 1 L Continuous Combustion Capacity MAX 49 4 h 65 9 h MIN 12 5 h 14 5 h Suitable room size in m MAX 120 MIN 48 184 MIN...

Отзывы: