TO THE INSTALLER

Model SB25

To the Installer 

comply with applicable national, state, and local codes. 

Water temperature is not to exceed 125°F (51°C). Water 

pressure to the machine must be 55 psi to 100 psi 

(379 kPa to 690 kPa).

Water Connections

An adequate cold water supply must be provided with a 

hand shutoff valve. Depending on local water conditions, 

it may be advisable to install a water strainer to prevent 

foreign substances from clogging the water valve.

IMPORTANT! 

A backflow prevention device is 

required on the incoming water connection side of the 

machine. Please refer to the applicable national, state, 

and local codes for determining the proper configuration.

All connections to the main water source must be 

performed by a licensed plumbing professional and meet 

all national, state, and local codes.

The potable water source should be filtered.

Water pressure to the machine should range from 55 psi 

to 100 psi (379 kPa to (690 kPa).

Hot or cold water may be used. Hot water is 

recommended for better rinsing. The temperature must 

not exceed 120°F (49°C).

The water line must be equipped with a manual shutoff 

valve to stop water flow in case of emergency or if repairs 

are necessary.

Drain Hose Connection

The drain hose must be attached to the drain port 

connection on the bottom of the machine. Position the 

drain hose downward for maximum water flow.

Locate the nearest drain that can accommodate a 1-1/8 

in. (28.575 mm) diameter drain tube. A minimum of 1 in. 

(25 mm) air gap is required between the end of the drain 

tube and the drain to ensure proper flow. The drain tube 

must not be submerged.

Important! 

Machine must be installed on a level surface 

for proper drainage.

Note:  

Machines equipped with the optional Rinse 

Station do not require a drain tube be connected directly 

to the machine and the drain pan should be removed. 

Attach the drain tube to the rinse station.

Electrical Connections

In the United States, this machine is intended to be 

installed in accordance with the current edition of the 

National Electrical Code (NEC), ANSI/NFPA 70, which 

governs the installation of the machine at the local 

governmental level.

The purpose of the NEC code is the practical 

safeguarding of persons and property from hazards 

arising from the use of electricity. This code contains 

provisions considered necessary for safety.

In all other areas of the world, the machine should be 

installed in accordance with existing local codes. Please 

contact your local authorities.

Each machine requires one power supply for each data 

label on the machine. Check the data label(s) on the 

machine for branch circuit overcurrent protection or fuse, 

circuit ampacity, and other electrical specifications. Refer 

to the wiring diagram provided inside of the electrical box 

for proper power connections.

WARNING! 

This machine must be properly 

grounded. Failure to do so can result in severe personal 

injury from electrical shock.

FOLLOW YOUR LOCAL ELECTRICAL CODES.

Содержание SB25

Страница 1: ...OPERATOR S MANUAL Model SB25 Blended Ice Machine 4 21 14 Original Publication Updated 9 20 2019 Original Operating Instructions 081218 M...

Страница 2: ..._______________ Serial Number ____________________________________________________________ Electrical Specs Voltage__________________ Cycle__________ Phase__________________________________ Maximum Fu...

Страница 3: ...essories 4 3 Section 5 User Interface Recipe Upload Procedure 5 3 Calibration Procedures 5 4 Section 6 Operating Procedures Assembly and Setup 6 1 Basic Operation 6 1 4 Hour Cleaning Procedure 6 2 Dai...

Страница 4: ...ii 081218 M Table of Contents Section 8 Troubleshooting Guide Section 9 Parts Replacement Schedule Section 10 Limited Warranty on Equipment Section 11 Limited Warranty on Parts...

Страница 5: ...ock or hazardous moving parts as well as poor performance or damage to the machine WARNING This machine has many sharp edges that can cause severe injuries Site Preparation Review the area where the m...

Страница 6: ...he nearest drain that can accommodate a 1 1 8 in 28 575 mm diameter drain tube A minimum of 1 in 25 mm air gap is required between the end of the drain tube and the drain to ensure proper flow The dra...

Страница 7: ...for long periods or during initial installation shall have protective devices to protect against the leakage of current such as a GFI installed by authorized personnel to local codes Supply cords use...

Страница 8: ...1 4 TO THE INSTALLER Model SB25 To the Installer 1 Notes...

Страница 9: ...t all personnel understand their role in using and maintaining the machine If you require technical assistance please contact your local authorized Taylor distributor Note Your Taylor warranty is vali...

Страница 10: ...2 2 TO THE OPERATOR Model SB25 To the Operator 2 Notes...

Страница 11: ...he machine Failure to follow this instruction may result in electrocution WARNING Avoid injury DO NOT operate the machine unless it is properly grounded DO NOT operate the machine with fuses larger th...

Страница 12: ...he 2 water lines from the back of the machine Disconnect the cane pump line from the back of the machine 115V 60 Hz machines only IMPORTANT Access to the service area of the machine must be restricted...

Страница 13: ...Section 4 4 1 Model SB25 Operator Parts Identification 4 Operator Parts Identification SB25 Exploded View Figure 4 1 1 2 14 3 4 5 7 8 9 11 10 12 6 16 17 13 15...

Страница 14: ...5 Rod Pivot Actuator 081220 6 Actuator Rinse 081221 7 Grate Left 081228 8 Guard Splash 081122 9 Chute Shaver 081121 Item Description Part No 10 Lid Pour Pitcher 115V 081248 11 Pitcher Blender Unguarde...

Страница 15: ...Figure 4 2 Not Shown 1a 1b 2 3 1 Item Description Part No 1 Kit A Brush X68468 1a Brush End Door Spout SS 039719 1b Brush Mix Pump Body 3 X 7 White 023316 1c Brush Mix Tube 068460 Item Description Pa...

Страница 16: ...4 4 OPERATOR PARTS IDENTIFICATION Model SB25 Operator Parts Identification 4 Notes...

Страница 17: ...5 1 Model SB25 User Interface 5 User Interface 2014 Taylor Company Figure 5 1 Item Description 1 Rinser ON OFF Power Switch for Rinser Side 2 Shaver Blender ON OFF Power Switch for Shaver Side 3 KEY...

Страница 18: ...ey will shut down the machine and cancel the drink cycle Recipe Keys Selects pre programmed flavor recipes NO SUGAR Key 115V 60 Hz Machines Only Removes cane sugar from the drink recipe currently bein...

Страница 19: ...sed and sanitized during the Daily Cleaning and Sanitizing Procedures described on page 6 3 Recipe Upload Procedure The customer recipe information is held in the microprocessor memory Recipes distrib...

Страница 20: ...blink Press the recipe key to change the Shave calibration value Press the recipe key to change the Water calibration value Press the recipe key to change the Cane calibration value 115V 60 Hz machin...

Страница 21: ...he use of bagged ice is not recommended as it can jam the machine and damage the shaver blade The ice must be clean and free of debris Failure to follow this instruction may result in contaminated pro...

Страница 22: ...e quick connect coupling at the rear of the machine The fitting will click into place See Figure 6 3 Figure 6 3 Cane Priming 115V 60 Hz Machines When starting the machine for the first time or when re...

Страница 23: ...7 8 Return the pitchers to the machine Daily Cleaning and Sanitizing Procedures Note This procedure must be done at the close of business Important Make sure your hands are clean and sanitized before...

Страница 24: ...des that are very sharp Failure to follow this instruction may result in contaminated product or personal injury from blade contact Figure 6 9 6 Reinstall the ice hopper cover See Figure 6 10 Figure 6...

Страница 25: ...rom blade contact 14 Rinse the parts in cool clean water 15 Sanitize the parts in a cleaning sanitizing solution with an active chlorine concentrate of 100 PPM to 200 PPM Use warm water and follow the...

Страница 26: ...n the dispensing tubes 25 If required by your local code repeat the previous step using clean water 26 Repeatedly dip the spout brush into the pail of cleaning sanitizing solution and very carefully b...

Страница 27: ...5 Remove the dip tube from the cane sugar container or disconnect it from the BIB Place the dip tube in the pail filled with warm water 6 Place the blender pitcher on the blender base Note Remove and...

Страница 28: ...6 8 OPERATING PROCEDURES Model SB25 Operating Procedures 6 Notes...

Страница 29: ...d be stressed during the cleaning and sanitizing operations Troubleshooting Bacterial Count Thoroughly clean and sanitize the machine regularly including complete disassembly and brush cleaning Use al...

Страница 30: ...7 2 OPERATOR S CHECKLIST Model SB25 Operator s Checklist 7 Notes...

Страница 31: ...e technician d Broken fitting d Contact a Taylor service technician e Pump is not working e Contact a Taylor service technician 6 Recipe key 1 fast blink hopper lid sensor fault a Hopper cover is not...

Страница 32: ...r pitcher is damaged a Abuse or excessive wear a Replace the blender pitcher PROBLEM PROBABLE CAUSE REMEDY 19 Machine will not rinse a The power switch is in the OFF position a Place the power switch...

Страница 33: ...e 9 Parts Replacement Schedule Table 9 1 Must be replaced by an authorized service technician Description Every 3 Months Every 6 Months Annually Brushes Inspect and Replace if Necessary Minimum Shaver...

Страница 34: ...9 2 PARTS REPLACEMENT SCHEDULE Model SB25 Parts Replacement Schedule 9 Notes...

Страница 35: ...cated by the Product serial number Proof of purchase may be required at time of service 2 This limited warranty is valid only if the Product is installed and all required service work on the Product i...

Страница 36: ...roduct s data label will void this limited warranty 13 Any cost to replace refill or dispose of refrigerant including the cost of refrigerant 14 ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMME...

Страница 37: ...ed proof of purchase may be required at time of service 2 This limited warranty is valid only if the Part is installed and all required service work in connection with the Part is performed by an auth...

Страница 38: ...arranty service work promptly upon arrival 9 Failure damage or repairs due to faulty installation misapplication abuse no or improper servicing unauthorized alteration or improper operation or use as...

Страница 39: ...NCIDENTAL DAMAGES INCLUDING CLAIMS FOR LOST SALES LOST PROFITS PRODUCT LOSS PROPERTY DAMAGES OR SERVICE EXPENSES ARE EXPRESSLY EXCLUDED THE EXPRESS WARRANTIES MADE IN THIS LIMITED WARRANTY MAY NOT BE...

Страница 40: ...11 4 LIMITED WARRANTY ON PARTS Model SB25 Limited Warranty on Parts 11 Notes...