GAS SUPPLY AND PIPING
GAS SUPPLY
THIS FURNACE IS EQUIPPED
AT THE FACTORY FOR USE ON
NATURAL GAS ONLY. CONVER-
SION TO LP GAS REQUIRES A
SPECIAL KIT A
AV
VA
AIIL
LA
AB
BL
LE
E F
FR
RO
OM
M
T
TH
HE
E D
DIIS
ST
TR
RIIB
BU
UT
TO
OR
R. FAILURE TO
USE THE PROPER CONVER-
SION KIT CAN CAUSE FIRE,
CARBON MONOXIDE POISON-
ING, EXPLOSION, PROPERTY
DAMAGE, PERSONAL INJURY
OR DEATH.
See the conversion kit index sup-
plied with the furnace. This index
identifies the proper LP Gas
Conversion Kit required for each
particular furnace.
IMPORTANT: Any additions, changes
or conversions required for the furnace
to satisfactorily meet the application
should be made by a qualified installer,
service agency or the gas supplier,
using factory-specified or approved
parts.
IMPORTANT: Connect this furnace
only to gas supplied by a commercial
utility.
IMPORTANT: A U.L. recognized
fuel gas and CO detector(s) are rec-
ommended in all applications, and their
installation should be in accordance
with the manufacturer’s recommenda-
tions and/or local laws, rules, regula-
tions or customs.
GAS PIPING
Install the gas piping according to all
local codes and regulations of the utili-
ty company.
If possible, run a separate gas supply
line directly from the meter to the fur-
nace. Consult the local gas company
for the location of the manual main
shut-off valve. The gas line and man-
ual gas valve must be adequate in
size to prevent undue pressure drop
and never smaller than the pipe size
!
WARNING
FIGURE 23
GAS PIPING -- UPFLOW INSTALLATION
(GAS VALVE MAY BE DIFFERENT
THAN SHOWN)
A1122-01_1
T
TO
OP
P V
VIIE
EW
W O
OF
F G
GA
AS
S L
LIIN
NE
E A
AN
ND
D
V
VA
AL
LV
VE
E
IIN
N O
OP
PT
T.. P
PO
OS
SIIT
TIIO
ON
N
OPTIONAL GAS LINE
POSITION
PLUG
(IN NORMAL
POSITION)
MANIFOLD
PRESSURE TAP
MANIFOLD
GROMMET
GAS VALVE
DRIP LEG
4 TO 5 FT.
ABOVE FLOOR
REQ’D BY
SOME
UTILITIES.
NOTE:
WHEN GAS LINE IS IN OPT.
POSITION, SWAP LOCATION
OF GROMMET AND PLUG.
MANUAL
GAS VALVE
BURNERS
UNION
(TYPICAL INSTALLATION)
GROMMET
(IN NORMAL
POSITION)
IMPORTANT: Do not run a flexible gas connector inside the unit.
Содержание RGFG
Страница 70: ...70 FIGURE 49 UPFLOW SIDE FILTER LOCATIONS CUT OUT AND DRILL DETAIL ROD FILTER SUPPORT ANGLE ASSEMBLY I332 ...
Страница 72: ...72 FIGURE 50 TROUBLESHOOTING CHART MODULATING INTEGRATED FURNACE CONTROL IFC TROUBLESHOOTING GUIDE ...
Страница 73: ...73 FIGURE 50 CONTINUED TROUBLESHOOTING CHART CONTINUED ...
Страница 90: ...90 TABLE 24 CONTINUED FURNACE FAULT CODES EXPANDED W DESCRIPTIONS AND SOLUTIONS CONTINUED ...
Страница 91: ...91 FIGURE 51 WIRING DIAGRAM STEPPER MODULATING GAS VALVE FUEL CODE HU FURNACE MODEL IS RGFG ...