![Taylor RD25 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/taylor/rd25/rd25_operators-manual_3789364027.webp)
23
Models RD30/RC25
Troubleshooting Guide
150701
PROBLEM
PROBABLE CAUSE
REMEDY
PAGE
REF.
4. The freezing cylinder walls
are scored.
a. The scraper blades and/or
blade clips are damaged.
a. Replace the scraper
blades and/or clips.
12
b. The door bearing is
missing or worn.
b. Install or replace the door
bearing.
14
c. Unit was placed in AUTO
before all sanitizing
solution was removed
from freezing cylinder.
c. Place unit in AUTO only
after priming is complete
and all sanitizing solution
is removed.
15 - 18
d. Broken pins on beater
assembly.
d. Repair or replace the
beater assembly. Be sure
the scraper blades are
properly seated on pins.
12
e. The beater assembly is
bent.
e. Call service technician to
repair or replace the
beater and to correct the
cause of insufficient mix in
the freezing cylinder.
- - -
5. Unable to remove the
drive shaft.
a. There is lubrication on the
square end of the drive
shaft.
a. Do not lubricate the
square end of the drive
shaft. Contact a service
technician for drive shaft
removal.
11
b. Rounded corners of the
drive shaft, drive coupling
or both components.
b. Replace the drive shaft,
drive coupling or both
components.
- -
6. Excessive mix leakage in
the rear drip pan.
a. Improper or inadequate
lubrication on the drive
shaft o- ring or seal.
a. Use the correct lubricant
(Taylor Lube) and follow
proper lubrication
procedures.
11
b. Worn or missing o- ring or
seal on the drive shaft.
b. Replace rubber parts
every 3 months.
11
c. Worn rear shell bearing.
c. Contact a service
technician for component
replacement.
- -