7
Model C043
Safety
150302
S
DO NOT
allow untrained personnel to
operate this unit.
S
DO NOT
operate the unit unless all service
panels and access doors are restrained with
screws.
S
DO NOT
remove any internal operating
parts (including, but not limited to, freezer
door, beater, or scraper blades), unless all
control switches are in the OFF position.
Failure to follow these instructions may result in
severe personal injury, especially to fingers or
hands, from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
S
DO NOT
put objects or fingers in the door
spout. This may contaminate the product
and cause severe personal injury from blade
contact.
S
USE EXTREME CAUTION
when removing
the beater assembly. The scraper blades
are very sharp.
This unit must be placed on a level surface.
Extreme care should be taken when moving the unit
for any reason. Two or more persons are required to
safely move this unit. Failure to comply may result in
personal injury or damage to the unit.
Access to the service area of the unit must
be restricted to persons having knowledge and
practical experience with the unit, in particular as far
as safety and hygiene are concerned.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to
the cleaning section of this Operator Manual for the
proper procedure to clean this unit.
This unit is designed to maintain product
temperature under 41°F (5°C). Any product being
added to this unit must be below 41°F (5°C). Failure
to follow this instruction may result in health hazards
and poor freezer performance.
DO NOT
run the unit without product. Failure to
follow this instruction can result in damage to the
unit.
For Indoor Use Only:
The Model C043 is designed
to operate indoors, under normal ambient
temperatures of 70° - 75°F (21° - 24°C). The unit
has successfully performed in high ambient
temperatures of 104°F (40°C) at reduced capacities.
NOISE LEVEL:
Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of
1.0 meter from the surface of the machine and at a
height of 1.6 meters from the floor.
Minimum Air Clearances: Air Cooled Units
DO NOT obstruct air intake and discharge openings:
C043:
A minimum air clearance of 3” (76 mm) is
required on the left side and rear of the unit, and 0”
on the right side. The drip tray can be installed on
either side. That side requires 36” (914 mm) to allow
for installation and removal of drip tray. Allow 36”
(914 mm) at the rear of the unit for service access.
Each air cooled C043 requires three RC35 remote
condensing systems.
RC35 (used with air cooled C043 unit, only):
Each 60 Hz remote condenser requires a minimum
air clearance of 6” (152 mm) on three sides.
Each 50 Hz remote condenser requires a minimum
air clearance of 12” (305 mm) on three sides.
An air deflector must be installed on the condenser
side of each RC35 if the floor clearance is less than
5” (127 mm). (
Note:
The legs are typically mounted
on 4” x 4” lumber to achieve the minimum floor
clearance.)
Failure to allow adequate air clearance can reduce
the refrigeration capacity of the unit and possibly
cause permanent damage to the compressor.
Minimum Air Clearances: Water Cooled Units
C043:
The minimum air clearance requirement is 3”
(76 mm) on both sides and at the rear of the unit.
The drip tray can be installed on either side. That
side requires 36” (914 mm) to allow for the
installation and removal of the drip tray. Allow 36”
(914 mm) at the rear of the unit for service access.