1-2
TO THE INSTALLER
087482-M
To the Installer
1
Water Connections
Water-Cooled Units Only:
An adequate cold water
supply must be provided with a hand shutoff valve. On
the underside rear of the base pan, two 3/8 in. I.P.S.
water connections for inlet and outlet have been provided
for easy hookup. Water lines connected to the machine
should have 1/2 in. inside diameters. (Flexible lines are
recommended, if local codes permit.) Depending on local
water conditions, it may be advisable to install a water
strainer to prevent foreign substances from clogging the
automatic water valve. There will be only one water-in
and one water-out connection.
Do not
install a hand
shutoff valve on the water-out line! Water should always
flow in this order: first, through the automatic water valve;
second, through the condenser; and third, through the
outlet fitting to an
open trap drain
.
CAUTION!
A backflow prevention device is
required on the incoming water connection side on this
machine. Please refer to the applicable national state
and local codes for determining the proper configuration.
Failure to adhere to this safety precaution may result in
personal injury.
Electrical Connections
Each unit requires one power supply for each data label
on the unit. Check the data label(s) on the freezer for
branch circuit overcurrent protection or fuse, circuit
ampacity, and other electrical specifications. See the
wiring diagram provided inside the electrical box for
proper power connections.
In the United States, this equipment is intended to be
installed in accordance with the National Electrical Code
(NEC) ANSI/NFPA 70-1987. The purpose of the NEC
code is the practical safeguarding of persons and
property from hazards arising from the use of electricity.
This code contains provisions considered necessary for
safety. Compliance therewith and proper maintenance
will result in an installation essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
IMPORTANT!
An equipotential grounding lug is
provided with this machine. Some countries require the
grounding lug to be properly attached to the rear of the
frame by the authorized installer. The installation location
is marked by the equipotential bonding symbol (5021 of
IEC 60417-1) on both the removable panel and the
machine's frame.
IMPORTANT!
•
Stationary appliances which are not equipped
with a power cord and a plug or another device
to disconnect the appliance from the power
source must have an all-pole disconnecting
device with a contact gap of at least 0.125 in. (3
mm) installed in the external installation.
•
Appliances that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices to
protect against the leakage of current, such as a
GFI, installed by the authorized personnel to the
local codes.
•
Supply cords used with this machine shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
•
If the supply cord is damaged, it must be
replaced by an authorized Taylor service
technician in order to avoid a hazard.
!
FOLLOW YOUR LOCAL ELECTRICAL CODES.
Содержание C791
Страница 8: ...1 4 TO THE INSTALLER 087482 M To the Installer 1 ...
Страница 38: ...9 2 PARTS REPLACEMENT SCHEDULE 087482 M Parts Replacement Schedule 9 Notes ...
Страница 42: ...10 4 LIMITED WARRANTY ON EQUIPMENT 087482 M Limited Warranty on 10 Notes ...
Страница 46: ...11 4 LIMITED WARRANTY ON PARTS 087482 M Limited Warranty on Parts 11 Notes ...