20
Model C712
Important: To the Operator
070322
Listed below are the variable messages which will
appear, along with an explanation for the corrective
action.
NO FAULT FOUND -
There was no fault found in
the freezer. Nothing will appear on the screen after
this variable message appears.
BEATER OVERLOAD -
Place the power switch in
the OFF position. Wait 5 minutes for the machine to
cool. Press the beater reset button firmly. Place the
power switch in the ON position and restart in
AUTO.
HPCO COMPRESSOR -
Place the power switch in
the OFF position. Wait 5 minutes for the machine to
cool. Place the power switch in the ON position and
restart in AUTO.
HOPPER THERMISTOR BAD -
Place the power
switch in the OFF position. Call service technician.
BARREL THERMISTOR BAD -
Place the power
switch in the OFF position. Call service technician.
The FAULT HISTORY screen displays a history of
the faults. (See Figure 27.)
FAULT HISTORY
07/27/04
12:58
<
HPR THERM FAIL
>
EXIT
Figure 27
Use the arrow symbols to advance forward or
backward to view each screen. Listed below are the
variable messages that may appear.
Faults Occurring While in AUTO Mode
HPR>41F (5C) AFTER 4 HR -
The mix temperature
in the hopper was above 41
_
F (5
_
C) more than four
hours.
BRL>41F (5C) AFTER 4 HR -
The mix temperature
in the freezing cylinder was above 41
_
F (5
_
C) more
than four hours.
HPR>41F (5C) AFTER PF -
The mix temperature in
the hopper was above 41
_
F (5
_
C) more than four
hours following a power failure.
BRL>41F (5C) AFTER PF -
The mix temperature in
the freezing cylinder was above 41
_
F (5
_
C) more
than four hours following a power failure.
HPR>45F (7C) AFTER 1 HR -
The mix temperature
in the hopper was above 45
_
F (7
_
C) more than one
hour.
BRL>45F (7C) AFTER 1 HR -
The mix temperature
in the freezing cylinder was above 45
_
F (7
_
C) more
than one hour.
HPR>59F (15C) -
The mix temperature in the
hopper exceeded 59
_
F (15
_
C).
BRL>59F (15C) -
The mix temperature in the
freezing cylinder exceeded 59
_
F (15
_
C).
Note:
Refer to your local health codes regarding
temperature recommendations for procedures to
follow if these fault screens appear.
The SYSTEM INFORMATION is displayed on three
separate screens. The first screen contains the
control and software version installed in the
machine. (See Figure 28.)
SOFTWARE VERSION
C712 CONTROL UVC3
VERSION 1.04
> Next
Figure 28
Touch the SEL symbol to advance to the next
system information screen containing the software
language version. (See Figure 29.)
Language
V1.11 r 00 English 515
> Next
Figure 29
Touch the SEL symbol to advance to the third
system information screen containing the model bill
of material and machine serial number. Touching the
SEL symbol again will return to the Menu list.
(See Figure 30.)
B.O.M. C71233C000
S/N
K0000000
> Next
Figure 30