C712 Operator Training
-18-
Manual Brush Cleaning
Draining Product
Step 1
With a pail beneath the door spouts, touch the WASH and PUMP symbols and open
the draw valve.
Step 2
Drain the product from the freezing cylinder and the mix hopper.
Step 3
When the flow of product stops, touch the WASH and PUMP symbols, cancelling the
WASH and PUMP modes. Close the draw valve and push the prime plug down.
Step 4
Remove the cotter pin, mix feed tube, pump clip and the assembled air/mix pump.
Step 5
Repeat these steps for the other side of the machine.
Rinsing
Step 1
Pour two gallons (7.6 liters) of cool, clean water into the mix hopper. With the white
hopper brush, scrub the mix hopper and the mix level sensing probe. Using the
double ended brush, brush clean the mix inlet hole.
Note: Do not brush clean the mix inlet hole while the machine is in the WASH mode.
Step 2
With a mix pail beneath the door spout, raise the prime plug and touch the WASH
symbol.
Step 3
When a steady stream of rinse water is flowing from the prime plug opening in the
bottom of the freezer door, open the draw valve.
Step 4
Drain all the rinse water from the door spout. Close the draw valve and push the
prime plug down. Touch the WASH symbol, cancelling the WASH mode.
Repeat rinsing using clean, warm water until the water being discharged is clear.
Repeat these steps for the other side of the machine.
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
Содержание C712
Страница 1: ...Model C712...
Страница 2: ......