26
Models C709 & C717
Important: To the Operator
Use the arrow symbols to program the AUTO
START TIME by increasing or decreasing the hour
setting above the cursor. Touch the SEL symbol to
advance the cursor and program the minutes
setting. Touch the SEL symbol to return to the
previous screen with the new time setting displayed.
Touch the SEL symbol to exit the screen and return
to the Menu.
Standby Mode
The STANDBY option is used to manually place the
machine in the standby mode during long, no draw
periods. Select the STANDBY screen from the
Manager's Menu. Touch the SEL symbol to activate
Standby. Standby may also be entered by touching
the STANDBY key when not in the Manager's Menu.
Discontinue Standby operation by exiting the
Manager's Menu and select the AUTO mode.
STANDBY MODE
Yes
No
> Exit
Mix Level Audible
The MIX LEVEL AUDIBLE option, when enabled,
will alert the operator with an audible tone when
there is Mix Low or Mix Out condition. The following
screen is displayed upon selecting this option.
MIX LEVEL AUDIBLE
ENABLED
> Enable
Disable
Disable the audible tone feature by touching the
DOWN arrow symbol to move the arrow to
“Disable”. Touch the SEL symbol to save the new
setting and return to the Menu. The control panel
icons for Mix Low and Mix Out will illuminate as the
mix level drops in the hopper, but the audible tone
will be disabled.
Fault Description
The Fault Description screen will indicate if there is a
fault with the freezer and where the fault occurred.
When no faults are detected, the following screen
will be displayed.
FAULT DESCRIPTION
NO FAULT FOUND
Touch the SEL symbol to display the next fault
found or return to the Manager Menu if no other
faults exist. Touching the SEL symbol any time
faults are displayed will clear the faults, if corrected,
upon returning to the Menu screen.
Listed below are the variable messages which will
appear, along with an explanation for the corrective
action.
NO FAULT FOUND -
There was no fault found in
the freezer. Nothing will appear on the screen after
this variable message appears.
BEATER OVERLOAD -
Place the power switch in
the OFF position. Wait 5 minutes for the machine to
cool. Press the beater reset button firmly. Place the
power switch in the ON position and restart in
AUTO.
COMPRESSOR HPCO -
Place the power switch in
the OFF position. Wait 5 minutes for the machine to
cool. Place the power switch in the ON position and
restart in AUTO.
HOPPER THERMISTOR FAIL* -
Place the power
switch in the OFF position. Call service technician.
BARREL THERMISTOR FAIL* -
Place the power
switch in the OFF position. Call service technician.
*Note:
Three codes have been set up to assist in
diagnosing bad thermistor probes. If a probe has
shorted (resistance less than 1 ohm), “SHRT” will
display for its respective machine location. If the
probe is open (resistance above 1 megohm),
“OPEN” will display. If the actual probe environment
exceeds 200°F (93°C), the respective screen display
location will read “OVER”, indicating the temperature
is “out of range”.
COMP ON TOO LONG
- The compressor run time
exceeded the 11 minute timer.