18
Troubleshooting
Model 428
Troubleshooting Torque Components
A. A missing or worn guide bearing will cause
uneven movement of the rotor system and will
result in product inconsistencies (too stiff/too
thin). If product becomes too stiff, the door,
torque arm, torque rotor and torque lever may be
damaged.
B. Any distortion or incorrect assembly of the torque
rotor will damage the torque components.
C. If incorrectly sized, damaged or improperly
lubricated o-rings are used, the rotor, door,
torque arm, torque rotor and torque lever may be
damaged.
D. If the torque arm is missing, the product will
freeze and the pulley belt will begin slipping. The
beater reset will then deactivate freezer
operation. In addition, torque components may
be damaged.
Содержание 428
Страница 2: ......
Страница 13: ...9 Model 428 Systems and Controls Section 2 Systems and Controls S Refrigeration System S Torque Control...
Страница 14: ...10 Systems and Controls Model 428 Refrigeration System...
Страница 16: ...12 Systems and Controls Model 428 Notes...
Страница 25: ...21 Model 428 Parts Notes...
Страница 26: ...22 Parts Model 428 150205 Model 428 Exploded View Figure 1...
Страница 29: ...25 Model 428 Parts 141119 Beater Door A With Standard Door No Prime Plug Figure 3...
Страница 31: ...27 Model 428 Parts 150121 Beater Door A With Self Closing Prime Plug Door Figure 4...
Страница 33: ...29 Model 428 Parts 150715 Panel A Front X62986 12 Figure 5...
Страница 49: ...Model 428 062598 27 10 13 13 Taylor Company...
Страница 50: ...Model 428 062598 27Y 10 13 13 Taylor Company...