Electrical Connections
In the United States, this equipment is
intended to be installed in accordance with the
National Electrical Code (NEC), ANSI/NFPA
701987. The purpose of the NEC code is the
practical safeguarding of persons and property from
hazards arising from the use of electricity. This code
contains provisions considered necessary for safety.
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Each unit requires one power supply for each data
label on the unit. Check the data label(s) on the
freezer for branch circuit overcurrent protection or
fuse, circuit ampacity, and other electrical
specifications.
Refer to the wiring diagram provided inside of the
electrical box for proper power connections.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
Note:
This unit is provided with an equipotential
grounding lug that is to be properly attached to
either the rear of the frame or the under side of the
base pan near the entry hole for incoming power, by
the authorized installer. The installation location is
marked by the equipotential bonding symbol (5021
of IEC 604171) on both the removable panel and
the equipment's frame, as well as on the diagram.
S
DO NOT
operate the freezer with larger
fuses than specified on the data label.
S
Stationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source, must have an
allpole disconnecting device with a contact
gap of at least 3 mm installed in the external
installation.
S
Appliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected or not used for long
periods, or during initial installation, shall
have protective devices such as a GFI, to
protect against the leakage of current,
installed by the authorized personnel to the
local codes.
S
Supply cords used with this unit shall be
oilresistant, sheathed flexible cable not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomersheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the conductors from
abrasion.
Failure to follow these instructions may result in
electrocution or damage to the machine.
Beater Rotation
Beater rotation must be
clockwise
as
viewed looking into the freezing cylinder.
Disconnect all power to the unit.
Failure
to follow this instruction may result in electrocution.
To correct rotation on a singlephase unit, change
the leads inside the beater motor by following the
diagram printed on the motor label.
Содержание 428
Страница 2: ......
Страница 13: ...9 Model 428 Systems and Controls Section 2 Systems and Controls S Refrigeration System S Torque Control...
Страница 14: ...10 Systems and Controls Model 428 Refrigeration System...
Страница 16: ...12 Systems and Controls Model 428 Notes...
Страница 25: ...21 Model 428 Parts Notes...
Страница 26: ...22 Parts Model 428 150205 Model 428 Exploded View Figure 1...
Страница 29: ...25 Model 428 Parts 141119 Beater Door A With Standard Door No Prime Plug Figure 3...
Страница 31: ...27 Model 428 Parts 150121 Beater Door A With Self Closing Prime Plug Door Figure 4...
Страница 33: ...29 Model 428 Parts 150715 Panel A Front X62986 12 Figure 5...
Страница 49: ...Model 428 062598 27 10 13 13 Taylor Company...
Страница 50: ...Model 428 062598 27Y 10 13 13 Taylor Company...