background image

4

  

English

L-2066 Installation

SMX II Control Systems • Installation

Warning

Make sure all power is off before opening any
electrical box.

Installing the SMX Keypad/Display

To be operated satisfactorily, the SMX keypad/display
should be installed so it is both visible and accessible. It
should be placed in plain view and within easy reach of the
operator. Overhead locations are discouraged since they
make it very difficult to use the SMX control.

Select a spot on an interior, vertical surface. This can be an
inside or outside wall, partition or other permanent struc-
ture with rear access for wiring. The SMX control operates
on low voltage DC and is certified ignition-protected. The
space behind the SMX control does not have to be venti-
lated since the control components do not produce heat.

SMX II Only

The SMX II keypad/display requires a cutout of 2

9

/

16

" x 7

1

/

8

"

(65mm X 181 mm). (For SMXir keypad installation, refer to
drawing #086800 in the back of this manual.)

After cutting the hole for the keypad control, make sure it
fits and the printed circuit board is clear of the bulkhead
and that no objects of any kind are in a position to contact
the SMX circuitry. Plug the interconnect cable in and route it
to the Power/Logic (P/L) box. Refit the control in the hole
and secure it with four No. 6 x 

3

/

8

 inch screws. Hook the

decorative plastic cover at the top, press it flat from the top
down, and snap it in place at the bottom.

Retrofitting SMXir Keypad/Display to
Original SMX II or 3-knob

Adapter plates are available to cover the old vertical or
horizontal rectangular cutout and mount the SMXir keypad/
display. Part #5103612 is a black plate, and #5103612W is
white. Use adapter #4163805 to connect an existing CX
cable to the SMXir display. (Refer to the SMXCABLE
drawing, Figure 9, at the back of this manual.)

Installing the Power/Logic Box
(retrofit only)

All SX and FX systems with integrated SMX II controls have
the P/L box already installed on the unit.

In selecting a location for the Power/Logic box, bear in mind
that several sets of wires will be connected to it. Refer to
installation diagrams in this packet.

• The SMX P/L board is ignition protected, enclosed, and

operates in ambient temperatures up to 130°F (54°C).

• The P/L box may be installed in any position.

• The P/L board dissipates heat when operating, and must

be installed in a ventilated location.

• The P/L box is NOT waterproof and must be placed

where it will NOT get wet.

The power input to the board can be 115V or 230V. The
board automatically adjusts to either voltage.

Installing the Temperature Sensor
(remote systems and retrofit only)

The TSEP temperature sensor measures the cabin air
temperature and relays the information to the power/logic
board. The sensor is 1" long by ¼" diameter (25mm x 7mm
diameter) and is attached to a length of flat, 4-conductor
cable with a RJ-11 phone type plug at the end. Different
lengths of TSEP cables are available, from 2 feet to 80 feet
(.6m to 24m).

For best results, the sensor should be placed in the return
air path, away from the system evaporator coil. Directly
behind the return air grill is often a good location. The
sensor must not touch the evaporator coil, or be placed in
the discharge air.

With the TSEP in the return air path, use the default mode
of continuous fan operation for the most accurate tempera-
ture control. If intermittent fan operation is desired (fan on
and off with the compressor), the sensor must be wall
mounted on an INSIDE surface not subject to any influence
from heat outside of the area (including direct sunlight).
Thermistor covers are available from Taylor Made Environ-
mental, Inc. for wall mounting.

SX self-contained units with integrated SMX II P/L box will
have the TSEP already installed. On FX remote units, the
TSEP must be run from the P/L box on the FX unit to the
return air path of the cooling unit.

The TSEP cable plugs into the RJ-11 jack on the P/L board
marked “INSIDE TSE”. Coil up any excess cable, and tie out
of the way.

Содержание Cruisair SMX II

Страница 1: ...SMX II Control Systems DX English INSTALLATION OPERATION Revised 12 17 02 L 2066 LP 11 DIRECT EXPANSION SYSTEMS For Direct Expansion SMX II Control Systems using these displays...

Страница 2: ...Anti Ice Routine 9 Seawater Temperature and Your Cruisair System 9 Programming the SMX II System 9 Factory Memory Reset 9 Programming Summary Table 10 Custom Programming Record 10 Compressor Time Del...

Страница 3: ...y different parts required for a complete installation so make sure that you have all the necessary items when installing the system Two different keypad displays are available for use with SMX II con...

Страница 4: ...integrated SMX II controls have the P L box already installed on the unit In selecting a location for the Power Logic box bear in mind that several sets of wires will be connected to it Refer to insta...

Страница 5: ...dard phone cable will not work with SMX controls Pressure Switches retrofit only Standard SX and FX units that have an integrated SMX II P L box include both the high and low pressure switches already...

Страница 6: ...Mode Indicator Lights when you press the COOL key to select the cooling mode 10 Heat Mode Indicator Lights when you press the HEAT key to select the heating mode 11 COOL Key Turns the system on in th...

Страница 7: ...he SMXir remote also has two quick hit buttons that allow easy access to the humidity control program and the automatic changeover mode The remote has three buttons that are not used on SMX II systems...

Страница 8: ...ressor is running When the compressor cycles off the Cooling Indicator goes off but the Cool Mode Indicator stays on Heat Mode Press the HEAT key to select HEAT Mode The Heat Mode Indicator will light...

Страница 9: ...he efficiency of the system operation depends on both the seawater and cabin temperatures In cooling the air conditioner will work best in seawater temperatures below 90 F 32 C At higher water tempera...

Страница 10: ...Compressor Differential SLOW FAN 12 4 to 24 Fan Response Differential COOL SLOW 4 2 to 8 SLOW FAN FAST Before 8 98 Low Fan Speed DOWN SET 32 30 to 56 High Fan Speed SET SLOW 60 41 to 90 Fan Mode Cont...

Страница 11: ...2 1 5 The compressor differential is the temperature change needed for the compressor to cycle on and off The factory setting of 1 5 Fahrenheit should be adequate for most applications Differential se...

Страница 12: ...actory default is 60 While listening to the fan noise level use the UP key to raise the displayed value past the point that you can hear an increase in the fan noise level Press the DOWN key to lower...

Страница 13: ...le 10 min Dehumidification cycle 30 min The factory settings are adequate for most moderate climates and boats For humid climates you may wish to shorten the overall time period and extend the dehumid...

Страница 14: ...he display will flash LO AC for low AC This is a sustained shutdown and the system will not resume operation even if the line voltage rises to normal levels To reset press the OFF key Fault Shutdowns...

Страница 15: ...are number Press OFF Press OFF SET and FAN simultaneously Press COOL twice until display reads 68 Press UP once The display should read Version Number Press SLOW until display reads F2 Press UP once T...

Страница 16: ...those expressly authorized herein TME shall not be responsible for any liability or expense except as is specifically autho rized and provided in this section TME reserves the right to improve its pro...

Страница 17: ...dry and checked periodically for electrical leakage If any electrical leakage is detected the component should be replaced or the fault causing the leakage corrected before the component is put back i...

Страница 18: ...cluding Parts and Labor Cruisair Tempered Water New complete system installation using any member of the SMX family 2 year warranty including Parts and Labor NOTE Excludes pump which has a 1 year warr...

Страница 19: ...460V 3Ph 50 60 Hz Dwg No 084901 P1050 Fig 6 SMX II Retrofit Typ 3 knob Dwg No 084001 P 1063 A 284 Fig 7 SMX II Retrofit F20C 48RC to 3 knob term strip Dwg No 082605 P 1065 A 279 Fig 8 SMX II Retrofit...

Страница 20: ...20 L 2066 Fig 1 SXR7 16CK 115 230V 50 60Hz...

Страница 21: ...21 L 2066 Fig 2 SX7 24CK 115 230V 50 60Hz...

Страница 22: ...22 L 2066 Fig 3 FX5 36CK 115 230V 50 60Hz...

Страница 23: ...23 L 2066 Fig 4 FX48RC 230V 50 60 Hz...

Страница 24: ...24 L 2066 Fig 5 FX20DC FX48EC 230V 460V 3Ph 50 60Hz...

Страница 25: ...25 L 2066 Fig 6 SMXII Retrofit Typical 3 knob...

Страница 26: ...26 L 2066 Fig 7 SMXII Retrofit F20C 48RC to 3 knob term strip...

Страница 27: ...27 L 2066 Fig 8 SMXII Retrofit F20C 48RC to condensing unit...

Страница 28: ...28 L 2066 Fig 9 Cable Diagrams Old and New P L Boards...

Страница 29: ...29 L 2066 Fig 10 SMXIR Mounting Template and Instructions...

Страница 30: ...or SMXIRB F SMXIR Keypad Display Black Full Door SMXIRW F SMXIR Keypad Display White Full Door SMXIR REM SMXIR Remote Control 5103400 Replacement Full Door for SMXIRB Black 5103400W Replacement Full D...

Страница 31: ...il info wardsmarine com Cruisair Suncoast Inc Location St Petersburg FL USA Territory Tampa St Petersburg and surrounding areas Phone 727 526 7875 Fax 727 528 9519 Email cruisairsuncoast aol com Kansa...

Страница 32: ...Fax 242 356 5271 Email rolandknowles bahamas net bs Bahrain International Agencies Location Manama Bahrain Phone 973 728691 Fax 973 728412 Email service intercol com Benelux ASA Boot Electro BV Locati...

Страница 33: ...espolo Cinzia C Sne Location Bevazzana de Latisana UD Italy Territory Northeast Italy Austria Croatia Slovenia Phone 390 431 53 644 Fax 390 431 53 460 Email nautica centis nauticacentis it Web www nau...

Страница 34: ...65 6861 1188 Fax 65 6861 4263 Email tritex pacific net sg Web www tritex com sg Slovenia Nautica Centis di Nespolo Cinzia C Sne Location Bevazzana de Latisana UD Italy Territory Northeast Italy Austr...

Страница 35: ...ne 758 452 0205 Fax 758 452 0206 Email stlucia regiselectronics com Zambia Southern Power Products Location Cape Town South Africa Territory Angola Botswana Mozambique Nambia S Africa Zambia Zimbabwe...

Страница 36: ...enviro va com www tmenviro com Taylor Made is a registered trademark of Nelson A Taylor Co Inc the Taylor Made Group Logo is a trademark of Taylor Made Group Inc the Cruisair logo is a registered trad...

Отзывы: