8
After Sales Support TEL: 1300 922 271 EMAIL: [email protected]
Keep the noise emissions and vibrations to a
minimum.
•
Only use appliances which are in perfect
working order.
•
Service and clean the appliance regularly.
•
Adapt your working style to suit the
appliance.
•
Do not overload the appliance.
•
Have the appliance serviced whenever
necessary.
•
Switch the appliance off when it is not in
use.
•
Wear protective gloves.
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain residual
risks cannot be rules out. The following hazards
may arise in connection with the equipment’s
construction and layout:
1.
Lung damage if no suitable protective dust
mask is used.
2.
Damage to hearing if no suitable ear
protection is used.
3.
Health damage caused by hand-arm
vibrations if the equipment is used over a
prolonged period or is not properly guided
and maintained.
Warning!
The electric power tool generates an
electromagnetic field during operation. Under
certain circumstances this field may actively or
passively impede medical implants. To reduce
the risk of serious or fatal injuries, we recommend
persons with medical implants to consult their
doctor and the manufacturer of the medical
implant prior to using the equipment.
5. Before starting the
equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating
plate are identical to the mains data.
Always pull the power plug before making
adjustments to the equipment.
5.1 Installing the dust container (Figure 2/Item 5)
•
Slip the dust container (5) onto the
vacuumcleaner connector (a).
•
The dust is extracted directly through
the grinding/sanding paper and the
grinding/sanding plate and into the dust
container.
4. Technical data
Mains voltage:
230 V ~ 50Hz
Power input:
280W
Orbits:
0 - 10,000rpm
Protection class:
Class II /
Weight:
2.2 kg
Rectangular sanding/grinding plate:
Grinding/sanding area:
140 x 115mm
Abrasive paper size
(Velcro fastening system)
140 x 115mm
Abrasive paper size
(Clamping system)
180 x 115mm
Eccentric sanding/grinding plate:
Grinding/sanding area:
Ø 125mm
Abrasive paper size
Ø 125mm
Triangular sanding/grinding plate:
Grinding/sanding area:
82 x 109 x 106mm
(a x b x c; Fig. 1)
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60745
L
pA
sound pressure level
80 dB(A)
K
pA
uncertainty
3 dB
L
WA
sound power level
91 dB(A)
K
WA
uncertainty
3 dB
Wear ear-muffs.
The impact of noise can cause damage to
hearing.
Total vibration values (vector sum of three
directions) determined in accordance with EN
60745.
Vibration emission value ah = 14.495 m/s
2
K uncertainty = 1.5 m/s
2
Additional information for electric power tools
Warning!
The specified vibration value was established in
accordance with a standardized testing method.
It may change according to how the electric
equipment is used and may exceed the specified
value in exceptional circumstances.
The specified vibration value can be used to
compare the equipment with other electric power
tools. The specified vibration value can be used
for initial assessment of a harmful effect.