![Taurus 60 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/taurus/60/60_manual_821710062.webp)
Turbomachinery Package Specification
Taurus
60 Compressor Set and Mechanical Drive
Table 13. Exhaust System Specifications
Exhaust System
Temperature Class
T2
Total System Pressure Loss
Should Not Exceed 152 mm (6 In.) of Water
Exhaust Temperature
538°C (1000°F)
Nominal System Back Pressure
203 mm (8 in.) of water,
See Note (a)
Construction Materials
Exhaust Silencers
Carbon Steel
316L Stainless Steel (Optional)
Exhaust Ducting
Carbon Steel
316L Stainless Steel (Optional)
Exhaust Bellows Expansion Joint
Carbon Steel
316L Stainless Steel (Optional)
Solar’s Applicable Engineering Specifications
ES 1632
Exhaust Silencers for
Solar
Turbine Engines
Notes
:
(a)
Higher backpressures can be accommodated. The exhaust backpressure should be less
than 254 mm (10 in.) water column during gas turbine starting.
© 2009 Solar Turbines Incorporated. All rights reserved.
TPS60CSMD/309
61