English
water received plate, or drain out the water by
leaning the unit, then shift the unit mode to Fan
mode, and press the button till it low fan speed.
-Keep this mode for half day till the conduit is
dried. Doing like this can keep the inner unit dried
and not go mouldy.
- Turn off the unit and pull out the plug.
- Coil the wire and bind it together, then put it into
the accessories room.
- Separate the air-exhausted pipe and safely
keep it.
- Put the unit into a plastic bag, and then keep it
in a dried place.
- Take out the batteries of remote control and
safely keep them.
Anomalies and repair
- Take the appliance to an authorised technical
support service if product is damaged or other
problems arise. Do not attempt to disassemble or
repair the appliance yourself as this may be dan-
gerous.
- If any anomaly is detected, check the following
table:
Anomalies
Causes
Solutions
The unit does not
work
- No power supply
- Water full indicator illuminate
- Screen display “FL”
- Turn on the appliance
- Drain out the inner stored water
- Restart and put back to normal after
power cut and drainage
The unit does not
seem to perform
- Indirect sunlight
- Window or doors open
- Filter is very dirty
- Air inlet or air outlet is blocked
- Room temperature is lower than the
setting one.
- Draw the curtains
- Close windows and turn on another
air conditioner
- Clean or change the air filter
- Clean out the stemming
- Change the temperature setting
The unit noise is too
high
- The unit is not put on a flat surface
- Put the unit on a flat and stable sur-
face that can support its weight
Compressor does
not work
- Heat exceeded protection is active
- Re start the unit 3 minutes later till
the temperature low down
Detection codes
Meaning
E1 :
Coil temperature sensor failure
E2 :
Indoor temperature sensor failure
E4 :
Anti-freeze protection: when the coil tempera-
ture is below 0°C, the whole machine will stop.
When the coil temperature rose to 8°C or more,
the protection will leave, and it will restore to its
original work state.
Notice AC 260 KT.indb 25