21
J4
AUX
Quick coupling for the connection of the
T-WIFI
and
T-CONNECT
devices
* The outlets can be configured using the TAUPROG or TAUAPP (T-WIFI) (see relative instructions). The
standard configuration is shown in the table.
**
If Jumper J6 is not plugged in, energy saving mode will be activated and, at the end of each
manouvre, outputs 11-12, 12-13, 14-15, 16-17 and 16-18 will be switched off.
IMPORTANT:
•
Do not connect auxiliary relays or other devices tot he 18 V DC output (terminals 11 – 12) to
avoid malfunctions of the control unit. Use separated power supply / transformers instead;
•
do not connect switching feeders or similar apparatus close to the automation that may be
a source of disturbance.
5. LOGIC ADJUSTMENTS
Make the logic adjustments.
Note: when any adjusting devices (trimmers or dip-switches) on the control panel are operated,
a complete manoeuvre must be carried out in order for the new settings to take effect.
TRIMMER
T.R.A.
This trimmer may give some extra seconds – other than the ones already set in
learning mode – to the second gate leaf closing delay. Unless necessary, leave it
to the minimum value. By turning the trimmer clockwise will increase the extra
the second gate leaf closing delay;
FR.
obstacle detection sensitivity adjustment.
Note: by rotating the TRIMMER FR. clockwise the sensitivity of the gearmotor
to obstacles diminishes
and therefore the thrust force increases
; vice-versa, by
rotating it counter-clockwise, the sensitivity of the gearmotor to obstacles
increases
and therefore the thrust force diminishes
.
T.C.A.
Automatic Closing Time adjustment: from about 1 to 120 seconds (see dip-switch no. 1);
T.R.A
Dip switch
1
AUTOMATIC
CLOSING
On
when completely open, closure is automatic after the set time on the
T.C.A. trimmer has past.
Off
the closing manoeuvre requires a manual command.
2
2 / 4 STROKE
On
when the automation is operating, a sequence of opening/closing
commands causes the automation to OPEN-CLOSE-OPEN-CLOSE, etc.
Off
in the same conditions, the same sequence of commands causes the
automation to OPEN-STOP-CLOSE-STOP-OPEN-STOP, etc . (step-by step
function) (see also dip switch 4)
.
3
CLOSES AGAIN
AFTER THE
PHOTOCELL
On
after the photocell is activated (input 7 - 9), the automation closes au
-
tomatically after 5 seconds.
Off
function off.
4
NO REVERSE
On
the automation ignores the closure command during opening and auto-close time.
Off
the automation responds as established by dip switch No. 2.
5
PRE-
FLASHING
On
the pre-flashing function is enabled.
Off
the pre-flashing function is disabled.
6
FOTOTEST
On
the “photocell test” function is enabled.
Off
the “photocell test” function is disabled.
Note: leave OFF when photocells are not used.
7
OPENING
RAM BLOW
On
the “opening ram blow” function is on. This permits the release of the
electric lock (to be used only in the presence of an electric lock);
Off
the “opening ram blow” function is off;
ENGLISH