User Manual (English version)_V2.0
6
1.3 Range of Environmental Conditions
Environment
:
Both dry and wet location use
Ambient temperature
:
-40
℃
~+60
℃
(-40
℉
~+140
℉
)
Pollution degree
:
2
Relative humidity
:
5% ~ 95%R.H.
Altitude
:
Below 4,000 meters above sea-level
CAUTION
Recommended storage and transportation condition
:
environment temperature range
between -40
℃
~+60
℃
(-40
℉
~+140
℉
) and relative humidity range between
5%~95%R.H.
1.4 Measurement
Periodic measurement interval
:
Every 30 minutes / Every 1 hour
Measured data
:
Motor Operating Status/ 3-axis Vibration(RMS)/ Motor Power Frequency,
Motor Skin Temperature/ Runtime Hour/ Residual Battery Power
Analysis tools
:
3-axis Vibration Spectrum Analysis
Sensing specifications
:
Temperature sensor
Power frequency
Sensing Range
:
-40
℃
~+120
℃
Sensing range
:
5~75Hz
(-40
℉
~+248
℉
)
Resolution
:
0.1Hz
Resolution
:
0.1
℃
Accuracy
:
±0.25Hz
Accuracy
:
±1
℃
Vibration sensor
Battery
3-axis accelerometer ±16g
CR123A
Unit
:
Velocity mm/sec (RMS)
Battery type
:
Li-MnO
2
Range
:
10~1,000Hz
Voltage
:
3.0 Vdc
(not rechargeable or replaceable)