Before the onset of monsoon, check the pipe and tank insulation for
possible leakage. If damage has occurred to the tank or collector due to
tampering, ensure that the water doesn’t seep into the insulation. Use proper
sealant like M-seal for joining the openings susceptible to water seepage.
Once in a year drain the System by opening the cold-water outlet hose
connected from tank bottom to collector inlet.
Before draining, close the cold water Inlet gate valve.
After draining & cleaning, fix the hose back with the cold-water outlet
to the tank bottom; keep the cold water gate valve open once the cleaning is
over.
Draining should be done only in the evening when system is
‘COOL’.
Once in a year check for corrosion of sacrificial anode. Replace it
when found corroded.
For HHC systems, the makeup tank has to be topped up with anti freeze
solution OR soft water at regular intervals, if not, the system output will
come down.
Air vent as shown in the system schematic diagrams, is must for all installations
except for pressurized systems where Air release valve has to be provided.
Absence of Air vent OR Air release valve will damage the system & the same is not
covered under warranty in such condition.
System should be installed only by our authorized dealer / TBP representative as
per layout given in this manual.
Use only recommended pipe size for hot water external piping.
Ensure proper insulation of complete hot water piping.
External piping should not exceed 10 mtr. / 30 feet. If this exceeds, the system
output will be reduced on account of increased heat losses in the pipe line.
Immediately after installation, system must be filled with water. Otherwise,
in case of heavy wind, system may topple.
Grouting of the system is mandatory as shown in section 7
Содержание Zing
Страница 3: ...19 20...
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ...ALL DIMENSIONS ARE IN MM...
Страница 21: ...SECTION 7 SCHEMATIC LAYOUTS 18 ALL DIMENSIONS ARE IN MM...
Страница 22: ...ALL DIMENSIONS ARE IN MM...
Страница 28: ......
Страница 29: ......
Страница 30: ...5...