background image

Connecting procedure

Do not  use  a  Grounding  wire  between  the  BlueBox  and  the  embedded  target  since  it
would counteract the primary functionality of the Galvanic Isolation (GI) Adapter!

1. Make sure you select a suitable debug interface (SWD, JTAG) via switches SW1 and SW2 on
the GI Adapter. In opposite case you may damage the hardware.

2. Make sure your hardware is powered 

OFF

.

·

Embedded Target

·

BlueBox

·

GI Adapter

3. Connect a Debug Adapter to the BlueBox. Refer to the 

BlueBox

 User Manual for more details

on connecting the Debug Adapter.

4. Connect the Debug Adapter to the GI Adapter.

5. Connect 1:1 Ribbon cable which is delivered along this package to the GI Adapter. 

6.  Connect 1:1 Ribbon cable to the embedded target.

7. Connect BlueBox, GI Adapter and Target to the power supply.

Use only original iSYSTEM USB-C Power supply for powering and connecting with the GI
Adapter, otherwise the primary functionality of the GI Adapter would be counteracted.

8. Power 

ON

 the hardware in the following order:

·

BlueBox

·

GI Adapter

·

Target

If LEDs on the GI Adapter are 

OFF

, immediately turn everything 

OFF

Содержание i SYSTEM ARM

Страница 1: ...ARM Galvanic Isolation Adapter User Manual V1 2 March 2023...

Страница 2: ...by iSYSTEM AG and all rights are reserved Duplication of these documents is allowed for personal use In all other cases written consent from iSYSTEM is required iSYSTEM AG All rights reserved All tra...

Страница 3: ...Contents ARM 20 pin 2 54mm Galvanic Isolation Adapter Package content 5 Specifications 6 Device overview 7 Connecting procedure 10 Accessories 11...

Страница 4: ...case the first insulation barrier fails This is termed double or reinforced isolation How should a double isolation be implemented depends on the use case or application setup It is your responsibilit...

Страница 5: ...nic Isolation Adapter is delivered with the following components ARM 20 pin 2 54 mm Galvanic Isolation Adapter USB C Power supply Ribbon cable Ordering code IEA GI ARM Ordering code IT5V2AUSBC PS Orde...

Страница 6: ...ORM 560 V peak DEBUG TOOL SIDE Supply Voltage 5 V via attached power supply Max Supply Current 50 mA TARGET SIDE Supply Voltage 3 V 5 V via VREF Max Supply Current 50 mA PERFORMANCE JTAG Up to 50 MHz...

Страница 7: ...LEDs on the GI Adapter are OFF immediately turn everything OFF The side face of the Galvanic Isolation Adapter features D USB C Power supply socket PWR Use only original iSYSTEM USB C Power supply fo...

Страница 8: ...Both jumpers SW1 SW2 should be in the same position to achieve the desired debug interface The legend is printed on the housing Debug interface SW1 SW2 SWD JTAG...

Страница 9: ...1 2 NC Not Connected O JTAG nTRST 3 4 GND Ground O Not Connected JTAG NC TDI 5 6 GND Ground I O O SWD JTAG SWDIO TMS 7 8 GND Ground O SWD JTAG SWDCLK TCK 9 10 GND Ground I Return TCK RTCK 11 12 GND Gr...

Страница 10: ...BlueBox Refer to the BlueBox User Manual for more details on connecting the Debug Adapter 4 Connect the Debug Adapter to the GI Adapter 5 Connect 1 1 Ribbon cable which is delivered along this packag...

Страница 11: ...Probe IC50111 1 20 pin 2 54 mm ARM Debug Adapter IASAM40ARMPIN20 Samtec40 to 20 pin JTAG ARM Converter Please refer to the iC5700 BlueBox User Manual for all current iC5700 Accessories Find more infor...

Страница 12: ...information provided in this document at the time of publishing Whilst iSYSTEM reserves the right to make changes to its products and or the specifications detailed herein it does not make any represe...