65
Malfunctions
Technical data
Malfunction
Possible causes
Troubleshooting
Page
Machine without function
Machine is switched off
• Switch on the ON/OFF switch
61
No power supply
• Insert the power supply plug into
the mains socket
61
Power supply cord defect
• Replace the power supply cord
Defective ON/OFF switch
• Contact your service partner
Motor does not turn
• Contact your service partner
Machine switches off during opera
-
tion
Self-resetting temperature sensor
triggered
• Dust bag full
• Check the admission accessories
Poor suction performance
Hose or dust nozzle blocked (e.g.
bits of wood, bits of fabric)
• Remove any foreign matter
Dust bag full
• Change the dust bag
63
Hose not correctly installed
• Check the hose
Filter cloth soiled
• Clean or replace the filter cloth
63
Filter disc dirty
• Clean or replace the filter disc
63
Machine
vento 8S
Rated voltage
220-240V~
100-120V~
127V~
AC
Frequency
50-60
60
Hz
Rated power, nominal
1000
W
Dimensions (LxWxH)
42x39x34
cm
Power supply cord length
10
m
Maximum weight of operational machine
6
kg
Effective volume
8
l
Machine
vento 15S
Rated voltage
220-240V~
100-120V~
127V~
AC
Frequency
50-60
60
Hz
Rated power, nominal
1000
W
Rated voltage (max.)
1150
W
Dimensions (LxWxH)
42x39x48
cm
Power supply cord length
10
m
Maximum weight of operational machine
8
kg
Effective volume
15
l