Pos.
Plug
Description [plug]
Pin
Description [pin]
1
HS
Main rockingswitch
1 (OUT)
OUT main phase
=> Pump
=> Contactor K1
=> Magnetic valve DS1/DS2/DS3
2
HS
Main rockingswitch
2 (OUT)
OUT main neutral
=> Vacuum motor rockingswitch, further to
contactor K1
=> Pump
3
HS
Main rockingswitch
1a (IN)
IN main phase
=> contactor K1/K2
4
HS
Main rockingswitch
2a (IN)
IN main neutral
=> contactor K1/K2
5
BS
Vacuum motor/pump/dosing rockingswitch 1b (OUT)
Magnetic valve
=> DS1
=> DS3
6
BS
Vacuum motor/pump/dosing rockingswitch 2b (OUT)
(Not connected)
7
BS
Vacuum motor/pump/dosing rockingswitch 1 (IN)
Microswitch brush motor
=> contactor K2
8
BS
Vacuum motor/pump/dosing rockingswitch 2 (OUT)
Microswitch brush motor
9
BS
Vacuum motor/pump/dosing rockingswitch 1a (OUT)
Magnetic valve
=> DS2
10
BS
Vacuum motor/pump/dosing rockingswitch 2a (OUT)
Contactor K1
=> Vacuum motor
Table 1: Rockingswitch connector description