18

LIZ-060 October 26, 2020 Rev03

5.2.3.3 DIRECT CONNECT WITH BROKEN HYDRANT

Figure 5.2.3.3

5.2.3.4 CONNECTION WHEN THERE IS NO WATER MAIN

Figure 5.2.3.4

MONITOR

BOOSTER

BLIND FLANGE

HYDRANT

HOSE

FLOW

PORT C3

OUT OF SERVICE

PORT

C3

MONITOR

BOOSTER

BLIND FLANGE

CONCRETE

HOSE

FLOW

PORT C3

FORKLIFT SLOTS

Содержание ZCH1T1-OSC

Страница 1: ...and maintenance personnel with the operation servicing and safety procedures associated with this product This manual should be kept available to all operating and maintenance personnel Model ZCF1T3...

Страница 2: ...The purpose of the proof test is to be con dent the valve design may be safely operated at the rated operating pressure SAMPLE CONFIGURATIONS Model ZBAD31X00 with 4 ANSI 150 on side B 6 Storz on port...

Страница 3: ...ANSI 150 FLANGE INLET ADAPTER SIDE A OPTION G 4 3 MONITOR COMPATIBILITY AND INSTALLATION 4 3 1 MONITOR INSTALLATION USING CODE RPM DIRECT CONNECTION SIDE B OPTIONS 1 AND 2 4 3 2 MONITOR INSTALLATION U...

Страница 4: ...ly hose may reduce water flow and cause injury or death to persons dependent on water flow Avoid tight bends to minimize risk of hose line kinks WARNING Injury or damage can occur from an inadequately...

Страница 5: ...An alternate pulley set stored within the safety guard allows the oscillating speed to be doubled by exchanging the pulleys using common hand tools The Booster OSC is compatible with TFT Monsoon Typh...

Страница 6: ...ong with the corresponding weights and dimensions The model number and unique serial number of each Booster are located on the label above the external automatic drain as shown in Figure 3 4 Go to tft...

Страница 7: ...pter installed is designed for direct connection to the Task Force Tips Industrial Valve Under Monitor IVUM and Hydrant Under Monitor HUM Either of these products provide the valve needed to shut off...

Страница 8: ...rz 1T ZCC3 1T 3 2 1 4 6 0 Storz 1X ZCC3 1X 8 7 4 0 3 5 NH female thread 4N ZCC3 4N 3 1 1 4 4 0 NH female thread 4P ZCC3 4P 2 2 1 0 4 5 NH female thread 4R ZCC3 4R 3 6 1 6 5 0 NH female thread 4T ZCC3...

Страница 9: ...overlap with the main valve body are excluded from these dimensions SIDE B OPTIONS character position 6 CHARACTER PART NUMBER WEIGHT lb WEIGHT kg CODE RPM DIRECT CONNECTION STRAIGHT 1 A1026 1 8 0 8 C...

Страница 10: ...of residual Loctite in the screw holes 5 Follow steps 1 through 5 in Section 4 2 1 6 Install pulley housing using the four 3 8 16 x 1 5 long screws that were originally installed Apply Loctite 242 blu...

Страница 11: ...4 2 4 INSTALLATION USING 3 ANSI 150 FLANGE INLET ADAPTER SIDE A OPTION G When Side A option G is specified the 3 ANSI 150 Flange Inlet Adapter is pre installed on side A of the Booster Four 5 8 11 x...

Страница 12: ...injury Do not install shutoff valves downstream of Booster Do not exceed the lowest maximum operating pressure rating of any devices assembled together Do not exceed the lowest maximum flow of any of...

Страница 13: ...does not interfere with RC monitor Power Com Cable if applicable Reposition Clamp if needed 5 Tighten each screw gradually until both are finger tight with approximately equal spacing between opposit...

Страница 14: ...specified with inlet option W swivel base for Booster OSC only 1 Verify O ring size 243 is installed on monitor inlet barb and is free of debris Apply silicone grease over O ring 2 Depress the red lat...

Страница 15: ...ource to boost the pressure available to the monitor Port C3 also allows an inline eductor or other foam injection system to be attached to supply foam solution to the monitor See Section 6 0 on page...

Страница 16: ...or water supplies from other sources follow the instructions below 1 Close valve installed upstream of the Booster Side A Inlet 2 Connect a hose from the water supply to LDH Inlet Port C3 of the Boost...

Страница 17: ...with vehicle access routs maintained using hose bridges when needed The Booster and monitor can be relocated again and again to coordinate with re construction progress of fire main replacement progra...

Страница 18: ...03 5 2 3 3 DIRECT CONNECT WITH BROKEN HYDRANT Figure 5 2 3 3 5 2 3 4 CONNECTION WHEN THERE IS NO WATER MAIN Figure 5 2 3 4 MONITOR BOOSTER BLIND FLANGE HYDRANT HOSE FLOW PORT C3 OUT OF SERVICE PORT C3...

Страница 19: ...use a wrench to manually rotate the external OSC drive hex shaft and then pivot the monitor by hand B When flowing Continue to gently push the monitor against the toggle point As the oscillating mecha...

Страница 20: ...e 20 x 75 long screw from center of one pulley and set the parts aside temporarily Repeat for other pulley 3 Loosen thumb nut Section 8 2 number 9 on bottom of safety guard section 8 2 number 2 Remove...

Страница 21: ...e B outlet of the Booster only and does not include pressure losses of any upstream or downstream equipment such as hoses monitors and nozzles Figure 6 0 0 0 5 1 1 5 2 2 5 3 0 2000 4000 6000 8000 0 5...

Страница 22: ...ge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The orig...

Страница 23: ...8 1 SERVICE TESTING In accordance with NFPA 1962 equipment must be tested a minimum of annually Units failing any part of this test must be removed from service repaired and retested upon completion...

Страница 24: ...LACED BACK IN SERVICE appliances must be inspected to this list 1 There is no obvious damage such as missing broken or loose parts dents cracks corrosion or other defects that could impair operation 2...

Отзывы: