background image

©Copyright Task Force Tips LLC   2016-2019 

LIS-040 April 8, 2019 Rev02

9

10.0 EXPLODED VIEW AND PARTS LIST

13

12

15

14

17

16

18

40

39

39

38

43

45

44

42

41

46

47

48

11

10

21

22

34

19

37

28

29

30

35

23
24
25

31

32

33

26

27

19

21

22

34

28

29

30

35

31

32

33

26

27

1

23
24
25

20

36

36

1

4

3

2

9

8

3

2

5

6

7

5 49

ITEM DESCRIPTION

QTY PART #

1

GASKET - 1.5"

1 V3130

2

1/4-28 X 1/4 SOCKET SET SCREW

1 VT25-28SS250

3

3/16" SS BALL

48 V2120

4

COUPLING 1.5" ROCKERLUG

1 H694*

5

O-RING 141

1 VO-141

6

ANTI GG RING VO

1 P147

7

REDUCTION F INSERT

1 P119F

8

GASKET - 2.5"

1 V3190

9

COUPLING 2.5"NH ROCKERLUG

1

P205N

COUPLING 2.5"NPSH ROCKERLUG

P205I

10 HANDLE SUBASSEMBLY

1 HX920

11 3/16 X 9/16 HDP SPIROL

2 V2005

12 TRUNNION DRIVER

2 HX650

13 3/8-24 X 3/4 BUTTON HEAD

2 VT37E24BH750

14 DETENT SPRING

2 HM770

15 .243"TORLON BALL 

2 VB243TO

16 O-RING-118

2 VO-118

17 TEFLON TRUNNION SHIM

2 P170

18 TRUNNION - RIGHT

1 P120R

19 BACKUP RING -330 PTFE SINGLE TURN

1 VOB-330T

20 BASE 1.5"NHF X 1.5"NHM

1 SVF100NF 

21 STREAM PATTERN LABEL 

1 SVF131 

22 VORTEX PATTERN LABEL

1 SVF132

23 ROLLER

6 SVF114

24 VANE

6 SVF110

25 O-RING-015

6 VO-015 

ITEM DESCRIPTION

QTY PART #

26 CAM SCREW

3 HD780

27 CAM FOLLOWER

3 SVF121 

28 DOWEL PIN 

6 VP156X1.00 

29 BACKUP RING -332 PTFE SINGLE TURN 1 VOB-332T 
30 SHAPER

1 SVF120

31 DETENT SCREW

3 HD785

32 STO DETENT SPRING 

3 VM4200 

33 3/16" BALL

3 V2120-TORLON 

34 NAME LABEL

1 SVF130

35 RETAINER

1 SVF115

36 10-32 X 3/16 SET SCREW - NYLOK

2 VT10Y32SS187 

37 BASE 1.5"NHM FOR VALVE

1 SVF101NF 

38 O-RING-227

1 VO-227

39 BALL SEAT VALVE

2 P104

40 DELRIN VALVE BALL

1 P103

41 10-32 X 1/4 SOCKET SET SCREW

2 VT10Y32SS250

42 GRIP SPACER HANDLINE

1 HM693-H

43 PISTOL GRIP - BLACK

1 HM692-BLK

44 WASHER 

1 VM4901

45 3/8-16 X 1 SOCKET HEAD SCREW

1 VT37-16SH1.0

46 3/8-16 X 5/16 SOCKET SET SCREW

1 VT37-16SS313

47 TRUNNION - LEFT

1 P120L

48 DETENT VALVE BODY

1 P110

49 REDUCTION J INSERT

1 P119J

* - CONSULT FACTORY FOR SPECIAL THREADS

Содержание VORTEX

Страница 1: ...and understand the following 1 Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times 2 It is your responsibility to read and understand any user s instructions including purpose and limitations provided with any piece of equipment you may be called upon to use 3 It is your responsibility to kno...

Страница 2: ... FLOW CHARACTERISTICS AND CHARTS 5 0 NOZZLE CONTROLS 5 1 FLOW CONTROL 5 1 1 LEVER TYPE FLOW CONTROL 5 1 2 TIP ONLY 5 2 PATTERN CONTROL 6 0 USE WITH FOAM 7 0 USE OF NOZZLES 8 0 APPROVALS 9 0 COLOR CODED VALVE HANDLE AND PISTOL GRIP 10 0 EXPLODED VIEWS AND PARTS LISTS 11 0 WARRANTY 12 0 MAINTENANCE 12 1 FIELD LUBRICATION 12 2 SERVICE TESTING 12 2 1 HYDROSTATIC TESTING 12 2 2 FLOW TESTING 12 2 3 RECO...

Страница 3: ...eam and can result in injury death or loss of property See flow graphs or call 800 348 2686 for assistance WARNING The nozzle may be damaged if frozen while containing significant amounts of water Such damage may be difficult to detect visually and can lead to possible injury or death Any time the nozzle is subject to possible damage due to freezing it must be tested by qualified personnel before ...

Страница 4: ...ilable by request Two Vortex 2 5 models are available SVFV NJ Vortex with integrated detent ball valve SVFG NJ Vortex with integrated detent ball valve and pistol grip INLET THREADS OUTLET THREADS FOR CONNECTING TO SMOOTH BORE NOZZLE not included TWIST STREAM SHAPER TO SELECT STRAIGHT STREAM OR VORTEX DISPERSED PATTERN COUPLING PISTOL GRIP ON OFF FLOW CONTROL VORTEX TIP ONLY VORTEX WITH INTERGRATE...

Страница 5: ...50 200 Flow GPM 10 0 0 Figure 4 0 1 3 8 Waterway Flow Chart 3 3 NOZZLE COUPLINGS NH National Hose Threads per NFPA 1963 threads are standard on all nozzles Other threads such as NPSH National Pipe Straight Hose threads per ANSI ASME B1 20 7 can be specified at time of order CAUTION Nozzle must be properly connected Mismatched or damaged threads may cause nozzle to leak or uncouple under pressure a...

Страница 6: ...slowly to eliminate unnecessary strain on the hose and couplings and reduce pressure surges TFT recommends the use of a pistol grip for easier handling For additional stress reduction a hose rope or strap may also be used This permits more effective use and ease of advancement while minimizing strain and fatigue 5 1 FLOW CONTROL Open valve slowly to avoid sudden changes in nozzle reaction Close va...

Страница 7: ...ckwise moves the shaper to the straight stream position shown in figure 5 2 3 Twisting the shaper counterclockwise will result in an increasingly wider pattern until reaching the full Vortex pattern shown in figure 5 2 4 Allows up to 5 8 debris to pass TWIST CLOCKWISE FOR STRAIGHT STREAM TWIST COUNTER CLOCKWISE FOR FULL VOTREX Allows up to 5 8 debris to pass Figure 5 2 3 Straight Stream pattern se...

Страница 8: ...e fireground tactics and operations 8 0 APPROVALS Vortex 1 5 and 2 5 NH threaded nozzles meet the requirements of NFPA 1962 2013 and NFPA 1964 2008 WARNING There are a wide variety of foam concentrates Each user is responsible for verifying that any foam concentrate chosen to be used with this unit has been tested to assure that the foam obtained is suitable for the purpose intended WARNING Use of...

Страница 9: ...ION SHIM 2 P170 18 TRUNNION RIGHT 1 P120R 19 BACKUP RING 330 PTFE SINGLE TURN 1 VOB 330T 20 BASE 1 5 NHF X 1 5 NHM 1 SVF100NF 21 STREAM PATTERN LABEL 1 SVF131 22 VORTEX PATTERN LABEL 1 SVF132 23 ROLLER 6 SVF114 24 VANE 6 SVF110 25 O RING 015 6 VO 015 ITEM DESCRIPTION QTY PART 26 CAM SCREW 3 HD780 27 CAM FOLLOWER 3 SVF121 28 DOWEL PIN 6 VP156X1 00 29 BACKUP RING 332 PTFE SINGLE TURN 1 VOB 332T 30 S...

Страница 10: ...e discharge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The original purchaser of the equipment any person to whom it is transferred and any person who is an intended or unintended beneficiary of the equipment shall not be entitled to recover from TFT any...

Страница 11: ...45 kPa increments held for 30 seconds at each pressure up to the maximum pressure for which the nozzle is being tested and then held for one minute without leakage 5 There shall be no sign of leakage through the valve or shut off 12 2 2 FLOW TESTING Flow testing must be conducted in the following manner 1 The nozzle shall be mounted so that the flow rate and pressure through the nozzle and the pre...

Страница 12: ...A National Fire Protection Agency WARNING Any nozzle failing any part of the checklist is unsafe for use and must have the problem corrected before use or being placed back into service Operating a nozzle that has failed the checklist is a misuse of this equipment 12 3 REPAIR Factory service is available with repair time seldom exceeding one day in our facility Factory serviced nozzles are repaire...

Отзывы: