3.1  VARIOUS MODELS AND TERMS

Vortex 1.5” models are configured with 1.5”NH female threaded non-fulltime swivel couplings on the inlet and 1.5”NH male threads 

on the outlet for connecting to a smaller tip. Other threads are available by request. Three Vortex 1.5” models are available:

SVFT    Vortex tip-only
SVFV    Vortex with integrated detent ball valve
SVFG    Vortex with integrated detent ball valve and pistol grip

Vortex 2.5” models are configured with 2.5”NH female threaded fulltime swivel couplings on the inlet and 1.5”NH male threads on the 

outlet for connecting to a smaller tip. Other threads are available by request. Two Vortex 2.5” models are available:

SVFV-NJ Vortex with integrated detent ball valve
SVFG-NJ Vortex with integrated detent ball valve and pistol grip

INLET THREADS

OUTLET THREADS

FOR CONNECTING TO 

SMOOTH-BORE NOZZLE

(not included)

TWIST STREAM SHAPER 

TO SELECT STRAIGHT STREAM 

OR VORTEX DISPERSED PATTERN

COUPLING

PISTOL GRIP

ON

OFF

FLOW CONTROL

VORTEX

TIP ONLY

VORTEX 

WITH INTERGRATED 

DETENT BALL VALVE 

AND PISTOL GRIP

SERIAL NUMBER

TYPICAL SMOOTH-BORE NOZZLE

(not included)

SERIAL NUMBER

VORTEX

RTEX

TM

TM

Figure 3.1 Various Models and Terms

3.2 SPECIFICATIONS

Maximum operating pressure (with valve shut off)

300 psi / 21 bar

Operating temperature range of fluid

33 to 120°F / 1 to 50° C

Stored Temperature Rating

-40 to 150°F / -40 to 65°C

Materials used

Aluminum 6000 series hard anodized 

MIL8625 class 3 type 2, stainless steel 

300 series, nylon 6-6, nitrile rubber

Содержание Vortex 1.5"

Страница 1: ...nd understand the following 1 Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times 2 It is you...

Страница 2: ...FLOW CHARACTERISTICS AND CHARTS 5 0 NOZZLE CONTROLS 5 1 FLOW CONTROL 5 1 1 LEVER TYPE FLOW CONTROL 5 1 2 TIP ONLY 5 2 PATTERN CONTROL 6 0 USE WITH FOAM 7 0 USE OF NOZZLES 8 0 APPROVALS 9 0 COLOR CODED...

Страница 3: ...am and can result in injury death or loss of property See flow graphs or call 800 348 2686 for assistance WARNING The nozzle may be damaged if frozen while containing significant amounts of water Such...

Страница 4: ...lable by request Two Vortex 2 5 models are available SVFV NJ Vortex with integrated detent ball valve SVFG NJ Vortex with integrated detent ball valve and pistol grip INLET THREADS OUTLET THREADS FOR...

Страница 5: ...0 200 Flow GPM 10 0 0 Figure 4 0 1 3 8 Waterway Flow Chart 3 3 NOZZLE COUPLINGS NH National Hose Threads per NFPA 1963 threads are standard on all nozzles Other threads such as NPSH National Pipe Stra...

Страница 6: ...lowly to eliminate unnecessary strain on the hose and couplings and reduce pressure surges TFT recommends the use of a pistol grip for easier handling For additional stress reduction a hose rope or st...

Страница 7: ...kwise moves the shaper to the straight stream position shown in figure 5 2 3 Twisting the shaper counterclockwise will result in an increasingly wider pattern until reaching the full Vortex pattern sh...

Страница 8: ...fireground tactics and operations 8 0 APPROVALS Vortex 1 5 and 2 5 NH threaded nozzles meet the requirements of NFPA 1962 2013 and NFPA 1964 2008 WARNING There are a wide variety of foam concentrates...

Страница 9: ...ON SHIM 2 P170 18 TRUNNION RIGHT 1 P120R 19 BACKUP RING 330 PTFE SINGLE TURN 1 VOB 330T 20 BASE 1 5 NHF X 1 5 NHM 1 SVF100NF 21 STREAM PATTERN LABEL 1 SVF131 22 VORTEX PATTERN LABEL 1 SVF132 23 ROLLER...

Страница 10: ...discharge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty...

Страница 11: ...5 kPa increments held for 30 seconds at each pressure up to the maximum pressure for which the nozzle is being tested and then held for one minute without leakage 5 There shall be no sign of leakage t...

Страница 12: ...National Fire Protection Agency WARNING Any nozzle failing any part of the checklist is unsafe for use and must have the problem corrected before use or being placed back into service Operating a noz...

Отзывы: