Task Force Tips Vortex 1.5

©Copyright Task Force Tips LLC   2016-2019 

LIS-040 April 8, 2019 Rev02

2

Table Of Contents

1.0 MEANING OF SAFETY SIGNAL WORDS
2.0 SAFETY
3.0 GENERAL INFORMATION
  3.1 VARIOUS MODELS AND TERMS
  3.2 SPECIFICATIONS
  3.3 NOZZLE COUPLINGS
  3.4 USE WITH SALT WATER
4.0 FLOW CHARACTERISTICS AND CHARTS
5.0 NOZZLE CONTROLS
  5.1 FLOW CONTROL
    5.1.1 LEVER TYPE FLOW CONTROL
    5.1.2 TIP ONLY
  5.2 PATTERN CONTROL
6.0 USE WITH FOAM
7.0 USE OF NOZZLES
8.0 APPROVALS
9.0 COLOR CODED VALVE HANDLE AND PISTOL GRIP
10.0 EXPLODED VIEWS AND PARTS LISTS
11.0 WARRANTY
12.0 MAINTENANCE
  12.1 FIELD LUBRICATION
  12.2 SERVICE TESTING
    12.2.1 HYDROSTATIC TESTING
    12.2.2 FLOW TESTING
    12.2.3 RECORDS
  12.3 REPAIR
13.0 OPERATION AND INSPECTION CHECKLIST

Содержание Vortex 1.5"

Страница 1: ...nd understand the following 1 Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times 2 It is you...

Страница 2: ...FLOW CHARACTERISTICS AND CHARTS 5 0 NOZZLE CONTROLS 5 1 FLOW CONTROL 5 1 1 LEVER TYPE FLOW CONTROL 5 1 2 TIP ONLY 5 2 PATTERN CONTROL 6 0 USE WITH FOAM 7 0 USE OF NOZZLES 8 0 APPROVALS 9 0 COLOR CODED...

Страница 3: ...am and can result in injury death or loss of property See flow graphs or call 800 348 2686 for assistance WARNING The nozzle may be damaged if frozen while containing significant amounts of water Such...

Страница 4: ...lable by request Two Vortex 2 5 models are available SVFV NJ Vortex with integrated detent ball valve SVFG NJ Vortex with integrated detent ball valve and pistol grip INLET THREADS OUTLET THREADS FOR...

Страница 5: ...0 200 Flow GPM 10 0 0 Figure 4 0 1 3 8 Waterway Flow Chart 3 3 NOZZLE COUPLINGS NH National Hose Threads per NFPA 1963 threads are standard on all nozzles Other threads such as NPSH National Pipe Stra...

Страница 6: ...lowly to eliminate unnecessary strain on the hose and couplings and reduce pressure surges TFT recommends the use of a pistol grip for easier handling For additional stress reduction a hose rope or st...

Страница 7: ...kwise moves the shaper to the straight stream position shown in figure 5 2 3 Twisting the shaper counterclockwise will result in an increasingly wider pattern until reaching the full Vortex pattern sh...

Страница 8: ...fireground tactics and operations 8 0 APPROVALS Vortex 1 5 and 2 5 NH threaded nozzles meet the requirements of NFPA 1962 2013 and NFPA 1964 2008 WARNING There are a wide variety of foam concentrates...

Страница 9: ...ON SHIM 2 P170 18 TRUNNION RIGHT 1 P120R 19 BACKUP RING 330 PTFE SINGLE TURN 1 VOB 330T 20 BASE 1 5 NHF X 1 5 NHM 1 SVF100NF 21 STREAM PATTERN LABEL 1 SVF131 22 VORTEX PATTERN LABEL 1 SVF132 23 ROLLER...

Страница 10: ...discharge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty...

Страница 11: ...5 kPa increments held for 30 seconds at each pressure up to the maximum pressure for which the nozzle is being tested and then held for one minute without leakage 5 There shall be no sign of leakage t...

Страница 12: ...National Fire Protection Agency WARNING Any nozzle failing any part of the checklist is unsafe for use and must have the problem corrected before use or being placed back into service Operating a noz...

Отзывы: