Task Force Tips TORNADO Скачать руководство пользователя страница 18

©Copyright Task Force Tips LLC 2008-2021

18

LIY-300 May 28, 2021 Rev19

6.4 STREAM STRAIGHTENERS

6.4.1 STREAM STRAIGHTENERS WITH STACKED TIPS

Turbulence though the Tornado monitor is very low, but stream quality and reach can be improved with the use of the integral stream

straightener on the TFT stacked tip nozzle. Stream straighteners will add some friction loss as indicated above.

6.4.2 STREAM STRAIGHTENERS WITH FOG NOZZLES

When using a fog nozzle for flows below 300 gpm (1,100 L/min), it is recommended that no stream straightener be used since the fog

nozzle’s  flow  path  serves  as  a  stream  straightener. Above  300  gpm  (1,100  L/min), TFT’s  5  inch  Stream  Straightener  will  generally

improve a fog nozzle’s stream.

7.0 WARRANTY

Task  Force  Tips  LLC,  3701  Innovation  Way,  Valparaiso,  Indiana  46383-9327  USA  (“TFT”)  warrants  to  the  original  purchaser  of  its

products  (“equipment”),  and  to  anyone  to  whom  it  is  transferred,  that  the  equipment  shall  be  free  from  defects  in  material  and

workmanship during the five (5) year period from the date of purchase. TFT’s obligation under this warranty is specifically limited to

replacing or repairing the equipment (or its parts) which are shown by TFT’s examination to be in a defective condition attributable to

TFT. To qualify for this limited warranty, the claimant must return the equipment to TFT, at 3701 Innovation Way, Valparaiso, Indiana

46383-9327 USA, within a reasonable time after discovery of the defect. TFT will examine the equipment. If TFT determines that there is

a defect attributable to it, TFT will correct the problem within a reasonable time. If the equipment is covered by this limited warranty, TFT

will assume the expenses of repair.
If any defect attributable to TFT under this limited warranty cannot be reasonably cured by repair or replacement, TFT may elect to

refund the purchase price of the equipment, less reasonable depreciation, in complete discharge of its obligations under this limited

warranty. If TFT makes this election, claimant shall return the equipment to TFT free and clear of any liens and encumbrances.
This is a limited warranty. The original purchaser of the equipment, any person to whom it is transferred, and any person who is an

intended or unintended beneficiary of the equipment, shall not be entitled to recover from TFT any consequential or incidental damages

for injury to person and/or property resulting from any defective equipment manufactured or assembled by TFT. 
It is agreed and understood that the price stated for the equipment is in part consideration for limiting TFT’s liability. Some states do not

allow the exclusion or limitation of incidental or consequential damages, so the above may not apply to you.
TFT shall have no obligation under this limited warranty if the equipment is, or has been, misused or neglected (including failure to

provide reasonable maintenance) or if there have been accidents to the equipment or if it has been repaired or altered by someone else.
THIS  IS A  LIMITED  EXPRESS  WARRANTY  ONLY.  TFT  EXPRESSLY  DISCLAIMS  WITH  RESPECT  TO  THE  EQUIPMENT  ALL

IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE.

THERE IS NO WARRANTY OF ANY NATURE MADE BY TFT BEYOND THAT STATED IN THIS DOCUMENT.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 

Содержание TORNADO

Страница 1: ...use of this equipment Obtain safety information at tft com serial number This equipment is intended for use by trained and qualified emergency services personnel for firefighting All personnel using t...

Страница 2: ...ctuator SECTION 4 17 Valve Kits YE VK PH SECTION 5 0 Troubleshooting SECTION 4 14 Multiplex Interface Control YE CAN SECTION 4 15 Ethernet Interface Control SECTION 4 9 Toggle Switch Monitor Operator...

Страница 3: ...TRUCTIONS 5 1 MANUAL TILLER MODEL SPRAY TRAJECTORY ADJUSTMENT 5 2 OPERATION OF OSCILLATING MONITORS 5 2 1 HORIZONTAL ROTATION CONTROL 5 2 2 ELEVATION CONTROL 5 2 3 TO ENGAGE THE OSCILLATING MECHANISM...

Страница 4: ...ry or damage can occur from an inadequately supported monitor The mounting must be capable of supporting the nozzle reaction force which can be as high as 1500 lbs WARNING The stream exiting a nozzle...

Страница 5: ...mental Instructions LIY 500 MANUAL ELECTRIC OSC US METRIC US METRIC US METRIC Weight 12 lbs 5 5 kg 25 lbs 11 4 kg 27 lbs 12 2 kg Minimum Flow Area 8 3 in2 24 5 cm2 8 3 in2 24 5 cm2 8 3 in2 24 5 cm2 Ma...

Страница 6: ...operate the monitor outside the envelope in the following graph s Tornado Operating Envelope Flow gpm Monitor Inlet Pressure psi Flow lpm Monitor Inlet Pressure bar 0 25 50 75 100 125 150 175 200 225...

Страница 7: ...hat uses a tiller bar to control horizontal rotation Electric remote control models are available in a standard model suitable for on top of pumpers a Ladder model and a Platform model The Ladder or P...

Страница 8: ...NH MALE Y2325ANF 2 5 BSP MALE Y2320ABJ TORNADO RC MODEL TORNADO TILLER BAR MODEL INLET COUPLING 2 5 7 5 NH 2 5 BSP FEMALE Y2405A 2 0 BSP FEMALE Y2425A 2 5 ANSI 150 Y2430A 3 0 ANSI 150 Y2431 2 5 NPT FE...

Страница 9: ...EMALE 1 50 38 mm Y2 6 A 2 5 ANSI 150 FLANGE 2 00 51 mm Y2 0 A 3 0 ANSI 150 FLANGE 2 10 53 mm Y2 7 A 2 5 8 NPT FEMALE 2 00 51 mm Y2 8 A 2 0 11 5 NPT FEMALE 1 50 38 mm Y2 9 A 3 0 8 NPT FEMALE 2 44 62 mm...

Страница 10: ...2 5 ANSI 150 FLANGE 0 60 15 mm Y2 SF A 3 0 ANSI 150 FLANGE 0 00 0 mm Y2 SG A 4 0 ANSI 150 FLANGE DN100 PN16 0 16 4 mm 90 45 185 LEFT 185 RIGHT 158mm 6 20 153mm 6 00 425mm 16 70 315mm 12 40 Figure 3 7D...

Страница 11: ...RNING Reaction forces generated by master stream flows are capable of causing injury and property damage if not properly supported Monitors should be securely installed by qualified individuals Mounti...

Страница 12: ...pling up and release the pin before installing monitor on the adapter Once the monitor is properly aligned on the adapter hold the pin out while sliding the coupling down to the adapter Rotate the cou...

Страница 13: ...connections may cause equipment to leak or uncouple under pressure Failure could result in injury Equipment must be mated to matched connections CAUTION Dissimilar metals coupled together can cause g...

Страница 14: ...in contact with an object The safety device will allow the mechanism to continue to oscillate the portion of its sweep path not blocked by the obstruction The safety mechanism also allows the oscillat...

Страница 15: ...h oscillation subtract 20 from the distance Figure 5 2 CAUTION Because the nozzle attached to the oscillator must slow down stop and reverse direction at the end of each sweep the ends of the covered...

Страница 16: ...S In the event of electrical system failure on the monitor or fire truck the Tornado RC monitor may be manually operated with factory supplied override knobs To make the Tornado RC more compact the ma...

Страница 17: ...0 PSI 1 25 INCH TIP HORIZONTAL DISTANCE M HORIZONTAL DISTANCE FEET VERTICAL DISTANCE FEET VERTICAL DISTANCE M 0 10 20 30 40 50 60 0 5 10 15 0 20 40 60 0 20 40 60 80 100 120 140 160 180 200 220 40 PSI...

Страница 18: ...ime If the equipment is covered by this limited warranty TFT will assume the expenses of repair If any defect attributable to TFT under this limited warranty cannot be reasonably cured by repair or re...

Страница 19: ...service is available with repair time seldom exceeding one day in our facility Factory serviced equipment is repaired by experienced technicians wet tested to original specifications and promptly ret...

Страница 20: ...appliances must be inspected to this checklist 1 All valves if so equipped open and close smoothly and fully 2 The waterway is clear of obstructions 3 There is no damage to any thread or other type co...

Отзывы: