background image

©Copyright Task Force Tips LLC 2020

2

LIM-027 December 15, 2020 Rev00

DANGER

PERSONAL RESPONSIBILITY CODE

The member companies of FEMSA that provide emergency response 
equipment and services want responders to know and understand the 
following:

1. Fire

¿

 ghting and Emergency Response are inherently dangerous activities 

requiring proper training in their hazards and the use of extreme caution 
at all times.

2. It is your responsibility to read and understand any user’s instructions, 

including purpose and limitations, provided with any piece of equipment 
you may be called upon to use.

3. It is your responsibility to know that you have been properly trained in 

Fire

¿

 ghting and /or Emergency Response and in the use, precautions, and 

care of any equipment you may be called upon to use.

4. It is your responsibility to be in  proper physical condition and to maintain 

the personal skill level required to operate any equipment you may be 
called upon to use.

5. It is your responsibility to know that your equipment is in operable 

condition and has been maintained in accordance with the manufacturer’s 
instructions.

6. Failure to follow these guidelines may result in death, burns or other 

severe injury.

FEMSA

Fire and Emergency Manufacturers and Service Association

P.O. Box 147, Lynn

¿

 eld, MA  01940 • www.FEMSA.org

Содержание Master Force ER

Страница 1: ...l and receiving proper training is a misuse of this equipment Obtain safety information at tft com serial number This equipment is intended for use by trained and qualified emergency services personnel for firefighting All personnel using this equipment shall have completed a course of education approved by the Authority Having Jurisdiction AHJ This instruction manual is intended to familiarize fi...

Страница 2: ...ent you may be called upon to use 3 It is your responsibility to know that you have been properly trained in Fire ghting and or Emergency Response and in the use precautions and care of any equipment you may be called upon to use 4 It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use 5 ...

Страница 3: ...e vertical distance to the target by maximum height from step 1 1 1 3 Calculate the Reach Factor by dividing the horizontal distance to the target by maximum reach from step 1 1 1 4 On the graph of nozzle trajectory elevation factors plot the intersection of the Height Factor and Reach factor from steps 1 2 and 1 3 If this point lies on or between the curves given estimate the appropriate elevatio...

Страница 4: ...ECIFICATIONS 3 4 USE WITH SALT WATER 3 5 ELECTRIC INSTALLATION 3 6 AUTOMATIC NOZZLE OPERATION 3 7 PATTERN CONTROL 3 8 STANDARD LOW PRESSURE KNOB 4 0 FLUSHING DEBRIS 5 0 USE WITH FOAM 5 1 FOAM ASPIRATING ATTACHMENT 6 0 FLOW CHARACTERISTICS 6 1 FLOW CHART 6 2 REACH AND TRAJECTORY 7 0 WARRANTY 8 0 MAINTENANCE 8 1 FIELD LUBRICATION 8 2 SERVICE TESTING 8 3 REPAIR 9 0 EXPLODED VIEWS AND PARTS LISTS 10 0...

Страница 5: ...water is turned on Do not direct water stream to cause injury or damage to persons or property WARNING Inadequately supported nozzle reaction force can result in injury or death The mounting must be capable of supporting the maximum nozzle reaction force as stated in the nozzle s manual WARNING Equipment may be damaged if frozen while containing significant amounts of water Such damage may be diff...

Страница 6: ...itors 3 1 VARIOUS MODELS AND TERMS Master Force nozzles are available in several different models and inlet connections Basic body styles are shown below Figure 3 1 3 2 MECHANICAL SPECIFICATIONS Table 3 2 3 3 ELECTRICAL SPECIFICATIONS Table 3 3 Manual Version ER Version Weight 9 5 lbs 4 3kg 14 2 lbs 6 4kg Flow Range 300 800 GPM 1100 3000 L min Operating Pressure Standard Mode 100 psi 7 bar Operati...

Страница 7: ...d be trimmed after changing the flow to obtain the straightest and farthest reaching stream To properly trim the stream first open the pattern to narrow fog Then close the stream to parallel to give maximum reach Turning the shaper further forward will cause stream crossover and reduce the effective reach of the nozzle 3 8 STANDARD LOW PRESSURE KNOB For situations where 100 PSI at the nozzle is im...

Страница 8: ...sed with foam solutions Refer to fire service training by the Authority Having Jurisdiction AHJ for the proper use of foam 5 1 FOAM ASPIRATING ATTACHMENT A low expansion aspirating attachment may be used with nozzles to increase the expansion ratio These foam tubes attach and detach quickly from the nozzle As expansion ratio is increased the reach of the nozzle will decrease due to the greater amo...

Страница 9: ...evations other than 30 degrees refer to document LTT 135 available at tft com Trajectories shown are for water The addition of foam is expected to decrease the reach by 10 Tail or head winds of 20 MPH 30 KPH may increase or decrease the range approximately 30 m CURVE GPM FLOW LBS REACTION CURVE L min FLOW KGF REACTION A 300 160 A 1100 70 B 400 210 B 1500 95 C 500 260 C 2000 120 D 600 320 D 2300 14...

Страница 10: ...e of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The original purchaser of the equipment any person to whom it is transferred and any person who is an intended or unintended beneficiary of the equipment shall not be entitled to recover from TFT any consequen...

Страница 11: ...one grease Once Break Free CLP is applied re application will be needed on a regular basis until the nozzle can be returned to the factory for a complete checkup and re lubrication with silicone grease 8 2 SERVICE TESTING In accordance with NFPA 1962 equipment must be tested a minimum of annually Units failing any part of this test must be removed from service repaired and retested upon completion...

Страница 12: ...ING PLACED BACK IN SERVICE nozzles must be inspected to this checklist 1 All controls and adjustments are operational 2 Shut off valve if so equipped closes off the flow completely 3 There are no broken or missing parts 4 There is no damage to the nozzle that could impair safe operation e g dents cracks corrosion or other defects 5 The thread gasket is in good condition 6 The waterway is clear of ...

Отзывы: