background image

©Copyright Task Force Tips LLC 2010-2021

3

LIU-330 February 15, 2021 Rev09

The member companies of FEMSA that provide emergency 

response equipment and services want responders to know and 
understand the following:

1.  Firefighting and Emergency Response are inherently 

dangerous activities requiring proper training in their hazards 
and the use of extreme caution at all times.

2. 

IT IS YOUR RESPONSIBILITY

 to read and understand 

any user’s instructions, including purpose and limitations, 
provided with any piece of equipment you may be called on 
to use.

3. 

IT IS YOUR RESPONSIBILITY

 to know that you have been 

properly trained in Firefighting and/or Emergency Response 
and in the use, precautions, and care of any equipment you 
may be called upon to use.

4. 

IT IS YOUR RESPONSIBILITY

 to be in proper physical 

condition and to maintain the personal skill level required to 
operate any equipment you may be called upon to use.

5. 

IT IS YOUR RESPONSIBILITY

 to know that your equipment is 

in operable condition and has been maintained in accordance 
with the manufacturer’s instructions.

6.  Failure to follow these guidelines may result in death, burns or 

other severe injury.

Fire and Emergency Manufacturers and Service Association, Inc. 
PO Box 147, Lynnfield, MA 01940 • www.FEMSA.org

© 2020 FEMSA. All Rights Reserved.

PERSONAL RESPONSIBILITY CODE

DANGER

Содержание EDUCTOR 125 Series

Страница 1: ...is intended for use by trained and qualified emergency services personnel for firefighting All personnel using this equipment shall have completed a course of education approved by the Authority Havin...

Страница 2: ...AM SELECTION 5 2 FOAM ATTACHMENT OPTIONS 5 3 FOAM CONSUMPTION 5 4 FOAM SUPPLY LOGISTICS 6 0 MAXIMUM HOSE LAY 7 0 NOZZLE SELECTION 7 1 NOZZLE COMPATIBILITY 8 0 WARRANTY 9 0 MAINTENANCE 9 1 SERVICE TEST...

Страница 3: ...SPONSIBILITY to know that you have been properly trained in Fire ghting and or Emergency Response and in the use precautions and care of any equipment you may be called upon to use 4 IT IS YOUR RESPON...

Страница 4: ...tuations WARNING This equipment is intended for use by trained personnel for firefighting Use of this equipment for other purposes may involve hazards not addressed by this manual Seek appropriate gui...

Страница 5: ...sion and is not covered under warranty 3 2 VARIOUS MODELS AND TERMS TFT 125 Series Eductors are available in several flows and with a variety of inlet couplings These must be specified at the time of...

Страница 6: ...water flow foam concentrate temperature and viscosity The user must verify that the concentrate s performance is suitable for use in their application Refer to training approved by the AHJ regarding f...

Страница 7: ...ing Foam Class Time to Empty 5 Gallons Foam Flow Rate 1 4 A 33 min 20 sec 0 15 gpm 057 L min 1 4 A 20 min 50 sec 0 24 gpm 0 9 L min 1 2 A 16 min 40 sec 0 3 gpm 1 14 L min 1 2 A 10 min 25 sec 0 5 gpm 1...

Страница 8: ...hose lengths can be used when proportioning rate is less because less work is needed to move lower total flows 7 0 NOZZLE SELECTION Eductors work with any nozzle whose gallonage is equal or greater t...

Страница 9: ...xed Pressure 15 30 45 60 75 gpm 55 110 170 230 285 L min 100 or 75 psi 7 or 5 bar FJ GD FJ LX U FJ UMX 1 0 G Force Automatic Pressure with Variable Flow 30 80 gpm 110 300 L min 100 or 75 psi 7 or 5 ba...

Страница 10: ...bar BUILT IN BUILT IN 1 5 G Force Selectable Flow Fixed Pressure 30 60 95 125 150 gpm 110 230 360 470 570 L min 100 or 75 psi 7 or 5 bar FJ LX G FJ MX G 1 5 G Force Automatic Pressure with Variable F...

Страница 11: ...L min 100 or 75 psi 7 or 5 bar FJ LX G FJ MX G 1 5 G Force Automatic Pressure with Variable Flow 60 150 gpm 230 570 L min 100 or 75 psi 7 or 5 bar FJ LX G FJ MX G Thunderfog FT200 FTS200 FTS 30 60 95...

Страница 12: ...300 L min 75 psi 5 bar FJ GD FJ LX U FJ UMX Ultimatic BL BTOL BHL BGHL 10 100 gpm 40 400 L min 100 psi 7 bar FJ U FJ LX U FJ UMX Metro 1 ME1 60 gpm 230 L min 75 psi 5 bar FJ HM FJ LX HM FJ MX HM 1 5...

Страница 13: ...5 G Force Selectable Flow Fixed Pressure 30 60 95 125 150 gpm 110 230 360 470 570 L min 75 psi 5 bar FJ LX G FJ MX G 1 5 G Force Automatic Pressure with Variable Flow 60 150 gpm 230 570 L min 75 psi...

Страница 14: ...rge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The ori...

Страница 15: ...est criteria should be removed from service immediately Troubleshooting guides are available with each test procedure or equipment can be returned to the factory for service and testing 10 0 TROUBLE S...

Страница 16: ...d foam suction hose are not obstructed 4 There are no leaks when the Eductor is flowing BEFORE BEING PLACED BACK IN SERVICE the Eductor must be inspected to this list 1 All controls and adjustments ar...

Отзывы: