background image

 

 

4

Description 
 

1.  Front of Sensor Box 

 

 

 

Relay Out:    

Plug the relay cable into this port. It connects directly to the                    

 

        device you want to control.

 

Relay On:     

This green light is on as long as the relay is closed/switch  

                       closure occurs.

 

 

 

Valid:

            The valid light flashes three times when the unit is turned 

                       on, when the dip switches are changed or the mode is set.

 

To Sensor:    

The end of the sensor plugs into this port.

 

Mode/Status: 

Flashes when switch closure occurs.

 

Sens Power:  

The red light blinks continuously as long as the sensor box has             

                       power

Off/On:          

Slide to off position when not in use.

 

 

Charge:         

The light stays on while the unit is being charged.

 

                          
 
 

Содержание SCATIR 51150

Страница 1: ...SCATIR Switch User Guide Model 51150 SCATIR Switch with Sensor Model 51200 SCATIR Switch with Eyeglass Mounting Kit Model 51250 SCATIR Switch with Gooseneck Mounting Kit Model 51300 SCATIR Switch Deluxe ...

Страница 2: ...ox page 4 Back of Sensor Box page 5 Bottom of Sensor Box page 6 Operation Dip Switches page 7 Adjusting Activation Distance page 7 Self Calibrating Mode page 8 Manual Calibrating Mode page 9 Auditory Tone page 10 Power page 11 Mounting Gooseneck page 12 Eyeglass page 13 ...

Страница 3: ...by persons who experience difficulty in activating mechanical switches It works by detecting a beam of reflected pulsed infrared light It is suitable for use with a variety of movements including eye blink eyebrow movement finger movement head movement or facial muscle movement The controlling body part does not need to be in physical contact with the switch sensor ...

Страница 4: ...e occurs Valid The valid light flashes three times when the unit is turned on when the dip switches are changed or the mode is set To Sensor The end of the sensor plugs into this port Mode Status Flashes when switch closure occurs Sens Power The red light blinks continuously as long as the sensor box has power Off On Slide to off position when not in use Charge The light stays on while the unit is...

Страница 5: ...5 2 Back of Sensor Box 12 24 VDC Plug the 12V charger into this port to charge the internal 9V rechargeable battery Battery This is a rechargeable 9 volt battery that has been installed for you ...

Страница 6: ... 3 Bottom of Sensor Box Dip Switches These switches are used to control the tone the sound of the tone and the calibration mode Set Switch This recessed switch is used when setting the manual calibration ...

Страница 7: ...4 Down Self Calibration SW3 Down SW4 Up 2 Adjusting Activation Distance The maximum distance allowed for activation activation distance can be adjusted from a few centimeters to less than a millimeter This adjustment can be made manually or automatically self calibration as explained below When the activation distance is reduced to its minimal value the switch simulates a zero force touch switch W...

Страница 8: ...itch will serve to define that distance as the activation distance Once activated at this distance the switch may be turned off by moving the body part completely out of the range of the sensor To set the self calibrating mode 1 Turn the sensor box off 2 Set the dip switches to SW3 Down SW4 Up 3 Position the sensor 4 Place the body part in front of the sensor 5 Turn the sensor box on Once activate...

Страница 9: ...he dip switches to SW3 Up SW4 Down 3 Position the sensor 4 Place the activating body part just beyond the desired activation distance 5 Turn the sensor box on 6 Press the set switch beside the Dip Switches with the end of a pencil until you hear three beeps and the valid light flashes three times 7 The manual calibrating mode is now set ...

Страница 10: ... of a dip switch The user can select either of two auditory feedback modes Beep Tone Mode A short momentary beep is emitted to indicate activation The relay light remains on throughout the full period of activation Continuous Tone Mode A tone is emitted which lasts as long as the switch is activated The relay light remains on throughout the full period of activation ...

Страница 11: ...of the SCATIR switch The yellow LED on the front of the box lights up to indicate that the charging current is going into the battery The charging time for a fully discharged battery is 8 hours with the SCATIR switch turned on or off Do not attempt to charge non rechargeable batteries Do not plug the charger into the SCATIR switch if a non rechargeable battery is installed ...

Страница 12: ... assist you in mounting the gooseneck The kit includes ABS Plastic Mounting Plate Adhesive backed Velcro Quick Release Gooseneck Mount assembly X saddle Self Tapping Screws 10 1 inch long Phillips flat head Band Clamp Multi bit Screw Driver For more mounting information please go to this site http www msu edu artlang SCATIR_Gooseneck Goosenec k 20Mount 20Kit 20Guide2 pdf ...

Страница 13: ... and polyurethane protective grommets Adhesive backed polyurethane tape Eyeglass frames Angled head infrared sensor cable You may wish to remount the sensor on another pair of frames The mounting kit provides additional materials to clamp the sensor in place on different frames The angled head sensor may be mounted on flat surfaces under clear lap trays or on surfaces of wheelchair armrests or hea...

Страница 14: ...u attempt to bend it you may need to loosen the clamp a bit and pull the head of the sensor a small amount away from the clamp to allow more freedom for bending it If you need to reshape the sensor with a large adjustment follow these directions Warm the sensor with a hair dryer Point the hair dryer at the sensor for one minute The heat softens the plastic and makes it more flexible Grasp the end ...