background image

 

5. How to Place the Probe 

 
Place the probe perpendicular to the contact surface  or 
facing to the direction wind is coming from. In addition, 
note that the unit will not operate properly if the surface is 
rough or uneven. 
 
* Before measurement, check the measurable range of 

the probe. If you measure a temperature beyond the 
range, there is a risk of failure and/unexpected injury. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

6. Maintenance 

 

(1) Storage 

When you store the unit, avoid such places as follows: 
  * Place exposed to direct sunlight 
  * Place that oscillates violently 
  * Place where the humidity is high (above 80%R.H.) 
  * Hot atmosphere (above 50°C) 
  * High electromagnetic field 
 

(2) If the Housing Gets Dirty 

If the housing gets dirty, immerse a shop towel in water or oil to wipe the housing. The housing is 
made of ABS resin. Do not use organic solvents such as thinner, benzine and alcohol. These 
solvents may deform and/or discolor the housing and keyboard. 
 
 

Содержание TA410AX

Страница 1: ...ital Thermometer TA410AX BX Instruction Manual Thank you for purchasing the TA410AX BX Digital Thermometer Please read this instruction manual carefully before use so that you can use the product properly ...

Страница 2: ... in some cases this could result in serious damage Symbols This symbol evokes your Attention This symbol denotes Don ts This symbol denotes Musts About the Main Unit Caution Do not use this product for improper purposes Stop using the product as soon as you notice an anomaly Do not disassemble or modify this product About the Battery Warning Never throw Never recharge the battery Use the designate...

Страница 3: ...ection 1 To install the probe insert the probe into the unit as in the right figure After installation lightly pull the probe to check that it will not come off 2 To remove the probe pull out the probe while pushing the probe stopper 3 To install the extension cord like the probe connect it to the unit as in the right figure To remove it like the probe pull out the cord while pushing the probe sto...

Страница 4: ...ans that the unit holds the indication of the constantly updated highest temperature If an error occurs the unit will hold the indication of the error 3 Minimum Value HOLD Feature MIN HOLD MIN and HOLD flashing on the display means that the unit holds the indication of the constantly updated lowest temperature If an error occurs the unit will HOLD the indication of the error 4 Average Value HOLD F...

Страница 5: ...4 ...

Страница 6: ...nstrument reading abnormally fluctuates check the probe 3 Low Battery Indication If the battery voltage gets low the low battery voltage indication will flash with 5 hours of life left In addition the whole display is programmed to blink with 30 minutes of life left The duration of the low battery voltage indication varies depending on the battery type and environment 4 Troubleshooting If you have...

Страница 7: ...ailure and unexpected injury 6 Maintenance 1 Storage When you store the unit avoid such places as follows Place exposed to direct sunlight Place that oscillates violently Place where the humidity is high above 80 R H Hot atmosphere above 50 C High electromagnetic field 2 If the Housing Gets Dirty If the housing gets dirty immerse a shop towel in water or oil to wipe the housing The housing is made...

Страница 8: ...7 MEMO ...

Страница 9: ...8 MEMO ...

Страница 10: ...9 MEMO ...

Страница 11: ...res and earthquakes Failures due to improper use inappropriate handling or modification Failures and damages not deemed to be our responsibilities Product Name TA410AX BX Serial Number Date of Purchase Authorized Dealer This warranty is void without the serial number date of purchase and authorized dealer Make sure to return this warranty together with the actual product ICHINEN TASCO CO LTD 1 17 ...